Table 6: PARTS LIST, Supreme with 1/3 HP and 1 HP motor: SUPxx-M2401A or SUPxx-M2401B 

 

ITEM

PART #

DESCRIPTION

COMMENTS

1A

B04114-01 HEATING ELEMENT PLATE ASSEMBLY SUP10kw (1/3 HP)

Item 12 included

1B

B04115-01 HEATING ELEMENT PLATE ASSEMBLY SUP15kw (1/3 HP)

Item 12 included

1C

B04116-01 HEATING ELEMENT PLATE ASSEMBLY SUP18kw (1/3 HP)

Item 12 included

1D

B04116-02 HEATING ELEMENT PLATE ASSEMBLY SUP20kw (1/3 HP / 1 HP)

Item 12 included

1E

B04117-01 HEATING ELEMENT PLATE ASSEMBLY SUP23kw (1/3 HP)

Item 12 included

1F

B04118-01 HEATING ELEMENT PLATE ASSEMBLY SUP23kw (1 HP)

Item 12 included

B04227

HEATING ELEMENT PLATE ASSEMBLY SUP25kw (1 HP)

Item 12 included

1G

B04119-01 HEATING ELEMENT PLATE ASSEMBLY SUP27kw (1 HP)

Item 12 included

2

B04075

FRONT DIVIDER ASSEMBLY

3

B03260-01 CASING ASSEMBLY

Item 4 included

4

B03302

CASING INSULATION

5

B04067

TOP PANEL 

6

B04068-01 SWITCH PLATE ASSEMBLY

Item 7, 8 & 9 included

7

L01J001

CIRCUIT BREAKER 15 AMP

8

L07F015

ROCKER SWITCH SPDT

9

L01L006

PILOT LIGHT

10

B03286

HEATING ELEMENT COVER

11A

L99H008

HEATING ELEMENT 5kw

11B

L99H009

HEATING ELEMENT 4kw

12A

R02N015

THERMODISK L150-55F

10 to 23kw - 1/3 HP

12B

R02N019

THERMODISK L140-55F

23 to 27kw - 1.0 HP

13

B03288

MOUNTING PLATE FOR ELECTRICAL, TOP

14

B04090

MOUNTING PLATE FOR ELECTRICAL, RIGHT SIDE

15

L05F004

TERMINAL STRIP, 4-POSITION

16

L01H009

RELAY SPDT 24 VAC

17

L01F009

TRANSFORMER 120-24 Volts

18A

L99F006

TERMINAL BLOCK

10kw

18B

L99F007

TERMINAL BLOCK

15 to 23kw

18C

L99F001

TERMINAL BLOCK

25 - 27kw

19

L01H030

RELAY DPST 22 VDC

20

R99G006

RECTIFIER CONTROL

21

R99G007

RECTIFIER/TIMER CONTROL

22A

B04125

ELECTRICAL KIT

10kw

22B

B04124

ELECTRICAL KIT

15kw

22C

B04123

ELECTRICAL KIT

18, 20kw

22D

B04122

ELECTRICAL KIT

23 25kw

22E

B04121

ELECTRICAL KIT

27kw

23

B04091

MOUNTING PLATE FOR ELECTRICAL, LEFT SIDE

24

B03265-01 TERMINAL BLOCK SUPPORT ASSEMBLY

25A

B04072-13 DOOR, ELECTRICAL COMPARTMENT

10kw

25B

B04072-14 DOOR, ELECTRICAL COMPARTMENT

15kw

25C

B04072-15 DOOR, ELECTRICAL COMPARTMENT

18, 20kw

25D

B04072-16 DOOR, ELECTRICAL COMPARTMENT

23 - 25kw

25E

B04072-17 DOOR, ELECTRICAL COMPARTMENT

27kw

26

B04093

BREAKER SUPPORT

27A

B04095

BREAKER PLATE

10kw

27B

B04096

BREAKER PLATE

15,18, 20kw

27C

B04097

BREAKER PLATE

23, 27kw

28A

L01J004

BREAKER 25 AMP

28B

L01J005

BREAKER 50AMP

29

B04094

PIVOT BREAKER

30

Z04F004

PAPER FILTER 20 x 20 x 1                   

31

B04071-01 DOOR, BLOWER COMPARTMENT

Item 32 included

32

B02293-22 BLOWER DOOR INSULATION

33

B03258

FLOOR ASSEMBLY

Item 34 included

34

B02293-21 FLOOR INSULATION

35

B03299

FILTER RACK ACCESS

36

B03298

FILTER RACK U-FRAME

37

B30513

BLOWER RAIL

38

B03264-02 BLOWER DIVIDER ASSEMBLY

Item 37 included

39A

B03301-01 REPLACEMENT BLOWER ASSEMBLY (1/3 HP)

Items 40, 41, 45 & 46 included

39B

B03318-01 REPLACEMENT BLOWER ASSEMBLY (1 HP)

Items 40, 41, 45 & 46 included

40A

B01291-04 SEAL STRIP (1/3 HP)

40B

B01291-01 SEAL STRIP 1 1/2" x 13 1/8" (1 HP)

41A

B03720-02 BLOWER 100-8R (1/3 HP)

41B

B03720-05 BLOWER 120-10T (1 HP)

42A

L01I001

CAPACITOR 5 MF (1/3 HP)

42B

L01I003

CAPACITOR 10 MF (1 HP)

43

B01024

CAPACITOR SUPPORT

44

B03303

BLOWER ELECTRICAL HARNESS

45A

B01888

MOTOR SUPPORT BAND AND LEGS (1/3 HP)

45B

B01889

MOTOR SUPPORT BAND AND LEGS (1 HP)

46A

L06G007

MOTOR 1/3 HP 120 V

46B

L06K004

MOTOR 1.0 HP 120 V

47

L01H009

ACCESSORY RELAY 24 VAC

Optional

ADAPTOR KIT 17"x17"

(Ref: B03883)

DOWNFLOW BASE FOR 23 KW UNITS OR MORE

(Ref: B03310-02)

SO

ACCESSORIES

AK

 

B50130B.xls 

Summary of Contents for SUPREME SUP10-M2401A

Page 1: ...J1L 1V8 Caution Do not tamper with the unit or its controls Call a qualified service technician Printed in Canada Printed on 100 recycled paper MULTI POSITION INSTALLER SERVICE TECHNICIAN USE THE INF...

Page 2: ...8 4 1 AIR FILTER 8 4 2 MOTOR LUBRICATION 8 5 0 FURNACE INFORMATION 9 TABLES Table 1 Supply air adjustment on heating mode 6 Table 2 Supply air adjustment on air cooling mode 6 Table 3 Technical speci...

Page 3: ...tch or circuit breaker ii The air filter and how to change it check monthly and clean or replace if necessary f Before calling for service be sure to have the information of section 5 of your manual c...

Page 4: ...o clearance to combustible material regardless of the heating capacity 2 2 2 Supply air ducts Ducts for furnaces with a heating capacity up to and including 20 k W can be installed with a zero clearan...

Page 5: ...acement these must be copper wires only with same temperature rating as originals 2 5 INSTALLATION OF THE THERMOSTAT A thermostat must be installed to control the temperature of the area to be heated...

Page 6: ...no way hinder access to the furnace panels 2 6 SUPPLY AIR ADJUSTMENTS On units equipped with 4 speed blower motors the supply air must be adjusted based on heating air conditioning output and the stat...

Page 7: ...door is in place and the blower rail locking screws are well tightened 3 The blower speed adjustments for heating and air conditioning are appropriate and according to the specifications in this manu...

Page 8: ...certain that the unit does not operate above the temperatures specified in the Technical Specifications Table 2 This is particularly important if a cooling coil or a heat pump has been installed in th...

Page 9: ...ler name and address START UP RESULTS Voltage Total current consumed by the elements Supply air temperature Return air temperature Supply air duct static pressure Return air duct static pressure Total...

Page 10: ...nd size Shipping weight Maximum cooling capacity ELECTRICAL SYSTEM GENERAL INFORMATION BLOWER DATA factory adjusted to a staic pressure of 0 5 W C 1 20 x 20 3 tons SUPxx M2401B 19 x 19 12 x 10 2 Calcu...

Page 11: ...11 Figure 9 Furnace dimensions...

Page 12: ...12 Figure 10 Wiring diagram 3 wires 10 kW...

Page 13: ...13 Figure 11 Wiring diagram 3 wires 15 kW...

Page 14: ...14 Figure 12 Wiring diagram 3 wires 18 20 kW...

Page 15: ...15 Figure 13 Wiring diagram 3 wires 23 kW...

Page 16: ...16 Figure 14 Wiring diagram 3 wires 27 kW...

Page 17: ...17 Figure 15 PARTS LIST Supreme with 1 3 HP and 1 HP motor SUPxx M2401A or SUPxx M2401B B50130A dwg...

Page 18: ...L 22A B04125 ELECTRICAL KIT 10kw 22B B04124 ELECTRICAL KIT 15kw 22C B04123 ELECTRICAL KIT 18 20kw 22D B04122 ELECTRICAL KIT 23 25kw 22E B04121 ELECTRICAL KIT 27kw 23 B04091 MOUNTING PLATE FOR ELECTRIC...