Table 5 : Parts List 

 

ITEM

NUMÉRO

DESCRIPTION

1

B02315

Heat exchanger ass'y

2

B03221-02

Lef t side panel ass'y

3

B01121-02

Lef t side insulation

4

B00725-02

Lef t side f ilter rack

5

B01157

Floor ass'y

6

B00703

Sensor support 

7

B01159-01

Front divider panel ass'y

8

B00698

Electrical element acces door ass'y

9

B01089

Ducting adapter w ith knockout

10

R02I002

High temp. control, HON L6064A, 11 1/2"

11

B02111

Observation door ass'y

12

B01137-01

Corner conduit

13

F06F005

Washer 3/8 zinc

14

F07F011

Hex nut 3/8-16 Zinc

15

B01026

Bottom divider plate ass'y

16

B01013

Gasket ring

17

B00725-01

Right side f ilter rack

18

B00658

Top divider plate

19

B00621-10

Insulation

20

B00621-09

Insulation

21

B00834-01

Sound trap insulation shield

22

B00711

Flue baf f le

23

B03357

Door ass'y

24

B00702-08

Sound trap gasket

25

B03359

Back top panel

26

J06L002

Extruded joint 1/4" x 1/8" x 25'

27

B02306

Flue gas outlet joint

28

B02317

Sound trap insulation

29

B02305

Holding plate

30

B02301

Breech plate gasket

31

B02311

Breech plate

32

B02312

Sound trap ass'y

33

F07O001

Hex nut ( brass )

34

Z99F050

Recessed handle, black

35

Z04F010

Paper f ilter 16" x 20" x 1"

36

Z04F001

Paper f ilter 10" x 20" x 1" 

37

B01024

Capacitor support

38

L01I001

Capacitor 5 MF

39

B01890-01

Motor assembly 1/3 HP (Motor, belly band and legs included)

40

B01888

Belly band assembly (belly band and legs included)

41

B01664-01

Wiring kit

42

Z01F006

Rubber grommet

43

B01756

Blow er rack

44

L04I010

Strain relief  bushing

45

B01404-01

Blow er ass'y

46

B03720-01

Blow er housing and w heel G10-10 DD

47

Z01L004

Blow er w heel G10 X 10 DD

48

B03221-01

Right side panel ass'y

49

B01121-01

Right side panel insulation

50

A00219

Terminal strip 12 position

51

L01H002

Relay SPST 24 VDC   

52

L04G004

Bushing 1 1/4"

53

L01F009

Transf ormer 120-24V  40 VA

54

L99F004

Supply block

55

B01125

Electrical mounting panel

56A

B02286-01

Component panel ass'y AME-15

56B

B02286-02

Component panel ass'y AME-20

56C

B02286-03

Component panel ass'y AME-25

57

L01H009

Relay SPDT 24 VAC

58

L01H011

Relay SPDT 120 VAC

59

L07F002

Rocker sw itch

Summary of Contents for LOW-BOY AME15-79

Page 1: ...79 AME20 90 AME25 100 DNS 0671 R v A C Fabriqu par Industries Dettson Inc 3400 boulevard Industriel Sherbrooke Qu bec Canada J1L 1V8 www dettson ca INSTALLATEUR TECHNICIEN UTILISER LES RENSEIGNEMENTS...

Page 2: ...igne de mazout 8 3 2 3 V rification de la combustion 9 3 2 4 V rification de l ajustement du ventilateur 9 3 2 5 V rification des limiteurs de temp rature 10 3 2 6 Ajustement du limiteur 10 3 2 7 V ri...

Page 3: ...ation de cet appareil par une personne non qualifi e peut endommager l quipement et ou conduire des conditions hasardeuses susceptibles d entra ner des dommages corporels IMPORTANT Toutes les exigence...

Page 4: ...contr le des odeurs D autre part en plus de l air de combustion une quantit suffisante d air doit tre fournie pour la ventilation incluant l air n cessaire pour le confort et des conditions de travai...

Page 5: ...11 Chemin es foyers vents et appareils de chauffage au combustible solide et ou CSA B139 Code d installation Cet appareil de chauffage central est homologu pour tre utilis avec un vent de type L temp...

Page 6: ...ce de votre unit et l amp rage nominal afin de choisir un disjoncteur et une protection de calibre suffisant L unit requiert une alimentation 240 120 Volts AC 60 Hz 3 fils plus mise la terre Installer...

Page 7: ...S il y a panne de ventilateur ou obstruction excessive dans le conduit d air chaud le g n rateur est muni d un contr le de haute limite qui emp che le br leur de surchauffer et d endommager le g n rat...

Page 8: ...peut tre allum ou non Voyant AUTO RELEVE et voyant ELECTRICITE Lorsque le voyant AUTO RELEVE est allum en m me temps que le voyant ELECTRICITE ceci signifie qu il y a un probl me sur le mode MAZOUT V...

Page 9: ...u un quivalent 3 Afin d effectuer la v rification de la combustion suivre les tapes suivantes a Percer un orifice d analyse des gaz de diam tre minimum appropri e environ 9 32 dans le tuyau de raccord...

Page 10: ...ider le bon fonctionnement de la prise BVSO sur l unit de chauffage seulement 1 Faire fonctionner le br leur 2 D brancher la prise 3 p les identifi e BVSO sur l unit 3 Le br leur doit s arr ter imm di...

Page 11: ...t pouvez inspecter visuellement ou l aide d un voltm tre chacun des l ments Si vous avez changer un l ment suivez la proc dure suivante 1 D branchez les 2 fils lectriques de l l ment retirer 2 D visse...

Page 12: ...t adresse du technicien de service R SULTAT DU TEST DE MISE EN MARCHE Gicleur Pression lb po 2 Ajustements du br leur Bande principale Bande fine Position de la t te CO2 Indice de fum e Bacharach Temp...

Page 13: ...van 0 65 80W 0 75 80W 0 85 80W Ajustement air de combustion bande obturateur 0 7 1 4 0 9 SYST ME LECTRIQUE Volts Hertz Phase 240 120 60 1 Contr le du transformateur 40 VA DONN ES TECHNIQUES DU VENTILA...

Page 14: ...MENT APPLICATION D GAGEMENT MINIMUM FOURNAISE 15 cm 6 PLENUM D ALIMENTATION 5 cm 2 AUTRE C T FOURNAISE 60 cm 24 ARRI RE FOURNAISE 60 cm 24 DESSUS FOURNAISE OU PLENUM 5 cm 2 DESSOUS FOURNAISE PLANCHER...

Page 15: ...15 Figure 3 Emplacement des composantes principales Figure 4 Localisation du tiroir d l ments DNS 0202 R v C DNS 0209 R v A...

Page 16: ...16 Figure 5 D montage du tiroir d l ment...

Page 17: ...17 Figure 6 Diagramme lectrique...

Page 18: ...18 Figure 7 Liste de pi ces B50047 Rev A...

Page 19: ...PLAQUE DE RETENUE 30 B02301 GARNITURE SORTIE DES GAZ 31 B02311 ASS SORTIE DES GAZ 32 B02312 ASS PIEGE A SON COMPLET 33 F07O001 ECROU HEXAGONAL A BRIDE 3 8 16NC LAITON 34 Z99F050 POIGNE ENCASTRE NOIR 3...

Page 20: ...SUS 70 B01154 PORTE D ACCES 71 B01095 ASS D LEMENTS 72 A00207 11 FIL ELECTRIQUE ROUGE 73 A00201 19 FIL ELECTRIQUE NOIR 74 L04J002 BRIDE DE CABLE 7 8 NOIR 75 B01123 03 TIROIR D L MENT 76 B01123 01 TIRO...

Page 21: ...Printed on 100 recycled paper DNS 0671 Rev A C Manufactured by Industries Dettson inc 3400 Industrial Boulevard Sherbrooke Quebec Canada J1L 1V8 www dettson ca INSTALLER SERVICE TECHNICIAN USE THE INF...

Page 22: ...OIL MODE 7 3 2 1 Operational checklist 7 3 2 2 Purging the oil line 8 3 2 3 Combustion check 8 3 2 4 Fan adjustment check 8 3 2 5 Limit Control check 9 3 2 6 Limit Control adjustment 9 3 2 7 BVSO perf...

Page 23: ...e installation of oil burning equipment wiring and flue connections must be followed some of the codes that may be applicable are CSA B139 Installation code for oil burning equipment ANSI NFPA 31 Inst...

Page 24: ...equate to provide air for combustion ventilation and dilution of flue gases This determination must be made on an individual installation basis and must take into consideration the overall volume of t...

Page 25: ...himney the chimney must be of sufficient area to accommodate the total flue products of all appliances vented into the chimney The following requirements are provided for a safe venting system a Ensur...

Page 26: ...y harm An internal filter rack located in the blower compartment is provided as standard equipment with this furnace A sufficient clearance should be provided for air filter access Refer to Table 2 fo...

Page 27: ...rner problem If the furnace is in the oil mode with both the AUTO RELIEF and OIL lights on there is a problem with the electrical system Twelve hours following detection of AUTO RELIEF the furnace wil...

Page 28: ...rformance from the oil burner the following set up procedures must be followed by referring to the Technical Specifications Table 2 in this manual 1 A test kit to measure the smoke flue draft and over...

Page 29: ...unction of the furnace and cause premature wear of the heat exchanger CAUTION Modification of the factory set limits will void the warranty 3 2 7 BVSO performance test The purpose of the following tes...

Page 30: ...lace an element follow the steps below 1 Disconnect the 2 wires attached to the element 2 Remove the metal screws that hold the frame on the drawer bottom of the drawer 3 Remove the frame by unscrewin...

Page 31: ...rvice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F A...

Page 32: ...le 100 PSIG pump pressure Delavan 0 65 80W 0 75 80W 0 85 80W Combustion air adjustment shutter band 0 7 1 4 0 9 ELECTRICAL SYSTEM Volts Hertz Phase 240 120 60 1 Control transformer 40 VA BLOWER DATA B...

Page 33: ...E A R A N C E S F U RN A CE 15 c m 6 S U P P LY P L E N U M 5 c m 2 O T HE R S I DE F U RN A CE 60 c m 24 B A C K F U RN A CE 60 c m 24 T O P F U RN A CE O R P LE NU M 5 c m 2 B O T T O M F U RN A CE...

Page 34: ...14 Figure 3 Location of main componants Figure 4 Location of element drawer DNS 0202 R v C DNS 0209 R v A...

Page 35: ...15 Figure 5 Element drawer removal...

Page 36: ...16 Figure 6 Electrical Diagram...

Page 37: ...17 Figure 7 Parts List B50047 Rev A...

Page 38: ...ation 29 B02305 Holding plate 30 B02301 Breech plate gasket 31 B02311 Breech plate 32 B02312 Sound trap ass y 33 F07O001 Hex nut brass 34 Z99F050 Recessed handle black 35 Z04F010 Paper filter 16 x 20...

Page 39: ...70 B01154 Acces door 71 B01095 Electrical element ass y 72 A00207 11 Red w ire 73 A00201 19 Black w ire 74 L04J002 Cable clamp 75 B01123 03 Element draw er 76 B01123 01 Element draw er 77 B01123 02 El...

Page 40: ...20...