OIL FURNACE 
UPFLOW AND 
HORIZONTAL 

Installation Instructions 

and 

Homeowner’s Manual 

 

INSTALLER / SERVICE TECHNICIAN : 
Use the information in this manual for the installation / servicing of the 
furnace and keep the document near the unit for future reference. 
HOMEOWNER : 
Please keep this manual near the furnace for future reference. 

Caution 

Do  not  tamper  with  the  unit 
or its controls. 
Call 

qualified 

service 

technician. 

Manufactured by 

 

 

Industries Dettson Inc 

Sherbrooke, Qc, Canada 

 
www.dettson.ca 

Model: 
 

AMP300B34-SE2PM 

DNS-0831 Rev A 

Summary of Contents for AMP300B34-SE2PM

Page 1: ...on in this manual for the installation servicing of the furnace and keep the document near the unit for future reference HOMEOWNER Please keep this manual near the furnace for future reference Caution...

Page 2: ...this manual can result in furnace malfunction property damage personal injury and or death WARNING Fire hazard The furnace must be installed in a level position never where it will slope toward the fr...

Page 3: ...n the water lines if possible Open faucets in appropriate areas b Have someone check the structure frequently during cold weather to make sure it is warm enough to prevent pipes from freezing Contact...

Page 4: ...ioration is discovered the chimney must be repaired or the vent must be replaced b Inspection to ascertain that the vent system is clear and free of obstructions Any blockages must be removed before i...

Page 5: ...ts and glues l Antistatic fabric softeners for clothes dryers m Acid based masonry cleaning materials 1 6 OIL TANKS AND LINES Check your local codes for the installation of the tank and accessories A...

Page 6: ...safety device must be installed between the flue outlet of the appliance and the draft regulator as indicated in the instructions It is further imperative that the BVSO be maintained annually For mor...

Page 7: ...time the burner motor ignition coil produces a spark 3 Spark ignites oil droplets 4 Cad cell senses flame and burner continues to fire Ignition transformer ceases sparking R40 F 5 After Fan Limit con...

Page 8: ...WER OFF DELAY BOARD ST9103A BLOWER ON DELAY BOARD 1158 2 2 5 Vent temperature test 1 Place a thermometer into the test hole located in the breech pipe 2 The vent temperature should be between 400 and...

Page 9: ...peration Soot will have collected in the first sections of the heat exchangers only if the burner was started after the combustion chamber was flooded with fuel oil or if the burner has been operating...

Page 10: ...remove any build up from the thermal switch surface 6 Clear and remove any build up or obstruction inside the heat transfer tube 7 Re mount lock and fasten the control box with the 2 screws removed i...

Page 11: ...TABLE 2 Technical specifications AMP300B34 SE2PMA OTF210G21B TABLE 2 1 Air delivery CFM with air filter AFUE value established after minimum 20 hours of operation 11...

Page 12: ...FIGURE 3 Model AMP300B34 SE2PMA OTF210G21B DNS 0822 Rev B TABLE 2 2 Minimum clearances combustible materials 12...

Page 13: ...FIGURE 4 Wiring diagram AMP300B34 SE2PMA OTF210G21B 13...

Page 14: ...14 PARTS LIST Model AMP300B34 SE2PMA OTF210G21B B50046A...

Page 15: ...15 PARTS LIST Model AMP300B34 SE2PMA OTF210G21B8...