Johnson Controls Ducted Systems

5396713-BIM-C-0319

ELECTRIC FURNACE

MODELS: EBE*/EUE*
Downflow/Upflow

INSTALLATION MANUAL

®

For Installation In:

1.  Manufactured (Mobile) Homes

2.  Recreational Vehicles & Park Models

3.  Modular Homes & Buildings

 LIST OF SECTIONS

GENERAL  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
UNIT INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ELECTRIC FURNACE INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . 4

THERMOSTAT INSTALLATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
OPTIONAL AIR CONDITIONING ACCESSORIES  . . . . . . . . . . . . . .  8
WIRING DIAGRAMS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9

LIST OF FIGURES

Furnace Dimensions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Alcove & Closet Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Upflow Closet Clearances  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Duct Connector Depth (7990 Series)  . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Duct Connector Dimensions (7990 Series)  . . . . . . . . . . . . . . . . . . . . . 4
Recommended Floor Cut-out (7990 Series)   . . . . . . . . . . . . . . . . . . . . 4
Duct Connector Screw Attachment (7990 Series)  . . . . . . . . . . . . . . . . 5
Duct Connector Tab Attachment (7990 Series)  . . . . . . . . . . . . . . . . . . 5
Installation of Furnace  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Field Wiring Shield  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
Control Box  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
Thermostat Wiring   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
EBE10*/EUE10* Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
EBE12*/EUE12* Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . .  10
EBE15*/EUE15* Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . .  11
EBE17*/EUE17* Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
EBE20*/EUE20* Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
EBE23*/EUE23* Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . .  14

LIST OF TABLES

Duct Connector for Electric Furnaces   . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wiring Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

EBE/EUE Series Blower Performance  . . . . . . . . . . . . . . . . . . . . . . . .  6
Physical and Electrical Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7

SECTION I: GENERAL

The following list includes important facts and information regarding the
EBE/EUE furnace and its packaging inclusions:

1.

Furnace is rated at 240 volts, 60 Hz, single phase.

2.

Filters are furnished with EBE model, and are the same for all EBE
models - 16 x 20 x 1 in top and 20 x 20 x 1 in the louvered door. No
filters are furnished with EUE models. External filter base and/or
filter rack is needed for field installation.

3.

Furnace size is the same for all models. See Figure 1.

4.

Four-wire thermostat operation for heating and cooling.

5.

Coil cavity built into furnace (coil shelf accessory required for EBE
model). 

6.

All furnaces are equipped with an air conditioner blower and is A/C
or Heat Pump ready (coil shelf accessory required for EBE model).

7.

Holding strap furnished on top rear of furnace.

8.

The EBE furnace is designed for downflow application, and the
EUE furnace is designed for upflow application. 

9.

This furnace must not be operated without the front panel
installed.

NOTICE

This furnace and its components listed on the A/C and Heat Pump
equipment sticker are listed in combination as a system by Under-
writer's Laboratories for the United States and Canada.

 FIGURE 1:  

Furnace Dimensions

51-5/8”

19-5/8”

OPTIONAL BOTTOM FIELD
WIRING ENTRY

A

B

C

D

E

F

H

G

J

K

L

M

N

1-7/8”

2-5/8”

3-1/2”

1”

5-1/16”

5-1/2”

1”

5-13/16”

1-3/4”

7-13/16”

8-5/8”

9-7/16”

16-1/2”

J
H

C B

A

D

E F

G

N

M

L

K

SUB-BASE, IF
USED, ADDS
7/8” MORE TO
TOTAL HEIGHT
AND 3/8” TO
WIDTH.

THERMOSTAT
WIRING
ENTRY

FIELD
WIRING
ENTRY

A0552-001

24”

Summary of Contents for EBE Series

Page 1: ...furnace and its packaging inclusions 1 Furnace is rated at 240 volts 60 Hz single phase 2 Filters are furnished with EBE model and are the same for all EBE models 16 x 20 x 1 in top and 20 x 20 x 1 i...

Page 2: ...8 Installing and servicing heating cooling equipment can be hazard ous due to the electrical components Only trained and qualified personnel should install repair or service heating cooling equip ment...

Page 3: ...led below furnace The return air opening can be located in a closet front door or a side wall above the furnace casing or in a louvered door on the furnace If opening for the return air is located in...

Page 4: ...rnace to an under the floor supply duct system The furnace may be installed on combustible flooring without a separate sub base TABLE 1 Duct Connector for Electric Furnaces FLOOR TO DUCT DIMENSIONS FI...

Page 5: ...ough and back up under the supply duct 8 Secure the duct connector to the floor with nails flat head screws or staples The duct connector is designed for use on ducts down to 12 in width When using th...

Page 6: ...reaker panel General wire and breaker sizes are shown in Table 2 If sheathed cable is used refer to National Electrical Code Canadian Electrical Code and local codes for additional requirements concer...

Page 7: ...other applicable codes 2 Does Not require a Jumper 3 Approved for Single Branch Circuit Service Only 4 Jumper provided for Single Branch Circuit Only 5 Requires Jumper Bars P N 3500 378P WARNING For p...

Page 8: ...n 19 1 2 no wider than 18 1 4 and no deeper than 20 1 2 EUE Furnace Models No extension cabinet and coil shelf are needed for the EUE upflow fur nace The coil shelf is already installed in the EUE mod...

Page 9: ...OCK SERVICE CONNECTION COVER MUST BE INSTALLED IF FILTERS ARE USED CLEAN REPLACE EACH SEASON OR MORE OFTEN AS NEEDED CAUTION IMPORTANT HIGH VOLTAGE WARNING 5395383 UWD B 1017 LINE LOAD XFMR 3A FUSE RE...

Page 10: ...ER MUST BE INSTALLED IF FILTERS ARE USED CLEAN REPLACE EACH SEASON OR MORE OFTEN AS NEEDED CAUTION IMPORTANT HIGH VOLTAGE WARNING 5395384 UWD B 1017 LINE LOAD XFMR 3A FUSE RED 8 RED 9 Y G W HEAT COOL...

Page 11: ...ED CAUTION IMPORTANT HIGH VOLTAGE WARNING 5395385 UWD B 1017 60 AMP CIRCUIT 1 BREAKER 60 AMP 240 VAC 60Hz 1 PHASE CIRCUIT 2 BREAKER GND LUG SINGLE BRANCH CIRCUIT SERVICE 240 VAC 60 Hz 1 PHASE REQUIRES...

Page 12: ...OR OTHER PROPER INSTRUMENT HAZARD OF ELECTRICAL SHOCK SERVICE CONNECTION COVER MUST BE INSTALLED IF FILTERS ARE USED CLEAN REPLACE EACH SEASON OR MORE OFTEN AS NEEDED CAUTION IMPORTANT HIGH VOLTAGE W...

Page 13: ...REPLACE EACH SEASON OR MORE OFTEN AS NEEDED CAUTION IMPORTANT HIGH VOLTAGE WARNING 5395388 UWD A 0717 LINE LOAD XFMR 3A FUSE RED 8 RED 9 Y G W HEAT COOL T STAT BLK 1 M3 M1 M2 H2 M5 M6 H4 H3 WHT BLK S...

Page 14: ...CH CIRCUIT SERVICE GND ECM ELECTRIC FURNACE 23kW CONDENSING UNIT CONTACTOR 240 VAC 60 Hz 1 PHASE REQUIRES JUMPER BARS P N 3500 378 YEL 13 WHT 11 M4 H1 RED SHOCK HAZARD THIS FURNACE MAY BE CONNECTED TO...