Table 11: Parts list with variable speed motor (ECM) 

ITEM

PART #

DESCRIPTION

COMMENTS

1

B03409

HEAT EXCHANGER

Heat exchanger only 

2

J06L002

SEAL STRIP, 1/4 x 1/8 x 25'

3

B03429

WIRE CHANNEL, INT.

4

B03420-01

FRONT PANEL ASSEMBLY

Panel, insulation and labels included

5

B03444

FRONT PANEL INSULATION

6

B03450-01

BAFFLE, LATERAL

7

B03426-01

SIDE PANEL ASSEMBLY (RIGHT)

Panel, insulation and baffle included

8

B03473

SIDE PANEL INSULATION

9

L04J001

CABLE CLAMP, 9/16" WHITE

10

F06F015

WASHER, ZINC 1 7/16"

11

Z99F061

OBSERVATION PORT

12

L04I013

STRAIN RELIEF BUSHING

13

B03447

WIRE CHANNEL

14

B03455-01

ELECTRICAL KIT, BVSO INT.

15

R02R006

HIGH LIMIT 36T01B7 150-20F, 7"

16

B03454

ELECTRICAL KIT, BURNER

17

B03453

ELECTRICAL KIT, TT

18

B03630-01

BAFFLE

One baffle included

19

B03416

RADIATOR BAFFLE

Item #49 included

20

F07O001

FLANGE NUT, HEXAGONAL 3/8-16NC BRASS

21

F07F011

HEX NUT 3/8-16NC ZINC  

22

Z99F050

HANDLE , RECESSED BLACK

23

B03419

BLOWER DOOR ASSEMBLY

Door and labels included

24

B03439

COVER, ELECTRICAL BOX

25

B03535-02

REPLACEMENT BLOWER ASSEMBLY

Blower, motor and capacitor included

26

Z06G001

BLOCKED VENT SHUT-OFF BVSO-225

27

B03118-01

ELECTRICAL KIT, BVSO EXT.

28

B03470

FLOOR

29

B03426-02

SIDE PANEL ASSEMBLY (LEFT)

Panel, insulation and baffle included

30

B03298

FILTER RACK ACCESS

31

B03450-02

LATERAL BAFFLE

32

B30513

BLOWER SLIDE

One slide included

33

B03441

BLOWER DIVIDER

34

B03451

REAR BAFFLE

35

B03427

REAR PANEL ASSEMBLY

Panel, insulation and baffle included

36

B03471

REAR PANEL INSULATION

37

B03242

ELECTRONIC KIT, BLOWER

38

B03243

ELECTRICAL KIT, BLOWER

39

B03456

ELECTRICAL KIT, BOARD

40

R99G003

ELECTRONIC BOARD, UTEC 1168

41

B03440

ELECTRICAL BOX

42

L01F009

TRANSFORMER, 120-24Volt, 40VA

43

B03438

SUPPORT, ELECTRONICS BOX

44

R02R007

HIGH LIMIT, 120-20F, 1.75''

45

B03437

BLOWER SLIDE

One slide included

46

B03720-02

BLOWER ASSEMBLY WITH LABEL

Housing, wheel and label included

47

B01888

MOTOR MOUNT ASSEMBLY

Legs, band and hardware included

48

L06H010

MOTOR, 1/2 HP ECM

49

B03428

SMOKE OUTLET GASKET

50

B03299

FILTER RACK FRAME

51

L01G009

CONTROL CARD FUSE - 3 AMPS

DOWNFLOW BASE

B03464-01

HORIZONTAL FLOW BASE

B00488-01

FILTER ADAPTOR

B03482-01

VENT TERMINAL KIT 4''

For sealed combustion

4" INSULATED FLEX VENT 10ft

For sealed combustion

4" INSULATED FLEX VENT 15ft

For sealed combustion

4" INSULATED FLEX VENT 20ft

For sealed combustion

BURNER BECKETT AFG (0,50-60A NOZZLE)

BECKETT NX BURNER (0.50-60W NOZZLE)

RIELLO 40-F3 BURNER (0.50-70A NOZZLE)

RIELLO 40-BF3 BURNER (0.50-70A NOZZLE)

For sealed combustion

PROTECTION PLATE BURNER NX

For down flow instalation only

IFV-410

IFV098-10

KLAFV0101DET

DFB-102

KLASB0801DET

HFB-101

KLASB0701DET

FRB-101

KLARB0101DET

VTK-54

VTK-098

KLAVT0101DET

N01F054 

KLABR101RLO

IFV-420

IFV098-20

KLAFV0201DET

IFV-415

N01F055 

KLABR201RLO

ACCESSORIES

B03789

N01J054
N01J050 

KLABR0101BEC

B50074K

 

 23

 

Summary of Contents for AMP098SD

Page 1: ...ard Sherbrooke Qc Canada J1L 1V8 Manufactured by Dettson Industries Inc Attention Do not tamper with the unit or its controls Call a qualified service technician INSTALLER SERVICE TECHNICIAN Use the information in this manual for the installation servicing of the furnace and keep the document near the unit for future reference HOMEOWNER Please keep this manual near the furnace for future reference...

Page 2: ...1 3 3 9 Restart after Burner Failure 11 4 MAINTENANCE 12 4 1 CLEANING THE HEAT EXCHANGER 12 4 2 CLEANING THE BLOCKED VENT SHUT OFF DEVICE BVSO 12 4 3 CLEANING OF THE BURNER HEAD 12 4 4 CHANGING THE NOZZLE 12 4 5 CHANGING THE OIL FILTER 12 4 6 CHANGING THE AIR FILTER 12 5 FURNACE INFORMATION 13 TABLES Table 1 Blower speed adjustments 4 speed motors 8 Table 2 Supply air adjustments ECM variable spee...

Page 3: ...hould be installed in your residence and properly maintained to warn early on of a potentially dangerous fire Also the house should be equipped with approved and properly maintained fire extinguishers Non observance of the safety regulations outlined in this manual will potentially lead to consequences resulting in death serious bodily injury and or property damage a It is the homeowner s responsi...

Page 4: ...n code for oil burning equipment ANSI NFPA 31 Installation of oil burning equipment ANSI NFPA 90B Warm air heating and air conditioning systems ANSI NFPA 211 Chimneys Fireplaces Vents and solid fuel burning appliances ANSI NFPA 70 National Electrical Code CSA C22 1 Canadian Electrical Code or CSA C22 10 Only the latest issues of these codes may be used 2 1 POSITIONING THE FURNACE WARNING Fire and ...

Page 5: ...e manner regardless of the discharge position of the furnace Refer to Figure 4 for additional details 2 3 ELECTRICAL SYSTEM CAUTION The exterior of the unit must have an uninterrupted ground to minimize the risk of bodily harm if ever an electrical problem develops A green ground screw is supplied with the control box for that purpose The appliance must be installed in accordance with the current ...

Page 6: ...instructions in this section Failure to properly vent this furnace can result in in death bodily injury and or property damage To ensure the safe and proper functioning of an oil furnace it must always be connected to a flue with sufficient draft or to an approved side wall venting system In addition it is strongly recommended to perform a complete inspection of all the existing venting systems No...

Page 7: ...FF DEVICE BVSO FOR CHIMNEY VENTING Refer to oil furnace installation codes relative to combustion and ventilation air requirements Consult Section 2 1 in this manual specifically for units installed in an enclosed space CAUTION It is imperative that this device be installed by a qualified service technician Home air exhausters are common Bathroom and kitchen fans power vented clothes dryers and wa...

Page 8: ...table as well as the air flow tables 7 and 8 based on static pressure finer filter must be installed on the oil supply line to the furnace inside the building where the unit is located This is a requirement in order for the heat exchanger warranty to remain in force Check your local codes for the installation of the oil tank and accessories Table 1 Blower speed adjustments 4 speed motors At the be...

Page 9: ... 1 2 POSITION USGPH OFF OFF A 0 70 ON OFF B 0 60 OFF ON C 0 50 ON ON D ALL 2 13 INSTALLATION OF ACCESSORIES WARNING Electrical shock hazard Turn OFF electrical power at the fuse box or service panel before making any electrical connections and ensure a proper ground connection is made before connecting line voltage Failure to do so can result in death or bodily injury 2 13 1 Humidifier HUM The 120...

Page 10: ...depends on the adjustments that were made on the electronic board that controls the blower Refer to Sections 2 11 and 2 12 as well as the CFM tables 7 and 8 for more details Note A detailed operating sequence of the oil burner is outlined in the instructions provided with the burner 3 3 CHECKS AND ADJUSTMENTS 3 OPERATION 3 3 1 Purging the oil line 3 1 START UP Open the bleed port screw and start t...

Page 11: ...s taken and make note of it Example 13 8 of CO or 2 5 of O 2 2 5 Adjust the burner air setting to obtain a CO2 reading 1 5 lower or a O2 reading 2 0 higher than the reading associated with the trace of smoke Example 12 3 of CO or 4 5 of O 2 2 3 3 8 Limit Control Check 6 This method of adjusting the burner will result in clean combustion Bacharach smoke scale between 0 and a trace and ensure the pr...

Page 12: ...o the unit 5 If ignition does not occur turn off the disconnect switch and call a qualified service technician 4 3 CLEANING OF THE BURNER HEAD When ordering replacement parts please specify the complete furnace model number and serial number Once annually remove the retention head and electrodes from the drawer assembly and remove all foreign matter if necessary Also clean the extremity of the bur...

Page 13: ...rvice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure Lb in 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Ambient temperature F Chimney draft W C Overfire draft W C Test performed by ...

Page 14: ...PSIG 155 145 135 155 145 Combustion air adjustment turbulator damper 0 1 50 0 2 1 2 25 0 1 50 0 2 AFUE From CSA B212 standard and Canadian regulation 85 6 85 3 84 0 85 6 85 3 AFUE From ASHRAE 103 standard and US regulation 85 1 85 0 83 3 85 1 85 0 Volts Hertz Phase Rated current Amps Minimum ampacity for wire sizing Amps Max fuse size Amps Control transformer VA External control power available He...

Page 15: ...2 ON 0 50 13 60 sec 13 60 sec 38 3 min D 1 ON 2 ON All 13 30 sec 100 30 sec 100 2 min No adjustment required A C size PreRun On Delay CFM Level Time ShortRun On Delay CFM Level Time Off Delay CFM Level Time All No delay No delay 100 90 sec PreRun and ShortRun are the periods of time when the blower starts at very low CFM to minimize the distribution of cool air in the system and then runs up to no...

Page 16: ...F FURNACE 1 5 08 cm 2 2 54 cm 1 5 08 cm 2 BOTTOM FURNACE 2 Ø 2 54 cm 1 3 5 08 cm 2 4 BACK FURNACE OPPOSITE SIDE OF THE BURNER 1 7 62 cm 3 2 54 cm 1 7 62 cm 3 PLENUM OR HORIZONTAL WARM AIR DUCT WITHIN 6 ft OF FURNACE 2 5 08 cm 2 5 08 cm 2 5 08 cm 2 FURNACE 2 N A 5 08 cm 2 N A FLUE PIPE AROUND FLUE PIPE 22 86 cm 9 22 86 cm 9 22 86 cm 9 FRONT FURNACE BURNER SIDE 1 45 72 cm 18 45 72 cm 18 45 72 cm 18 ...

Page 17: ...Figure 9 Furnace dimensions 17 ...

Page 18: ...Figure 10 Wiring diagram 4 speed motor PSC 18 ...

Page 19: ...Figure 11 Wiring diagram variable speed motor ECM 19 ...

Page 20: ...Figure 12 Parts list with 4 speed motor PSC 20 B50064H ...

Page 21: ...LOWER SLIDE One slide included 34 B03441 BLOWER DIVIDER 35 B03451 REAR BAFFLE 36 B03427 REAR PANEL ASSEMBLY Panel insulation and baffles included 37 B03471 REAR PANEL INSULATION 38 B03457 01 ELECTRICAL KIT BLOWER 39 L01I001 CAPACITOR 5MF 40 B01024 CAPACITOR HOLDER 41 B03456 ELECTRICAL KIT BOARD 42 R99G004 ELECTRONIC BOARD UTEC 1158 110 43 B03440 ELECTRICAL BOX 44 L01F009 TRANSFORMER 120 24Volt 40V...

Page 22: ...Figure 13 Parts list with variable speed motor ECM 22 B50074H ...

Page 23: ...0513 BLOWER SLIDE One slide included 33 B03441 BLOWER DIVIDER 34 B03451 REAR BAFFLE 35 B03427 REAR PANEL ASSEMBLY Panel insulation and baffle included 36 B03471 REAR PANEL INSULATION 37 B03242 ELECTRONIC KIT BLOWER 38 B03243 ELECTRICAL KIT BLOWER 39 B03456 ELECTRICAL KIT BOARD 40 R99G003 ELECTRONIC BOARD UTEC 1168 41 B03440 ELECTRICAL BOX 42 L01F009 TRANSFORMER 120 24Volt 40VA 43 B03438 SUPPORT EL...

Reviews: