Table 8: Airflow data, models with 1/3 HP PSC motors
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
HIGH
1230
1185
1150
1095
1050
990
920
810
595
MED-HIGH
1090
1055
1005
970
925
875
810
700
550
MED-LOW
865
860
860
845
795
740
695
600
460
LOW
675
680
690
680
665
640
565
480
390
External Static Pressure ("W .C.)
Speed
Table 9: Minimum clearances from combustible materials
UPFLO W
HORIZONTAL
DOWNFLO W
FURNACE
1
2. 54 cm (1")
N/ A
2. 54 cm (1")
PLENUM AND WARM-AIR DUCT WI THI N 6 f t. O F FURNACE
1
5. 08 cm (2")
2.54 cm (1")
5. 08 cm (2")
BOTTOM FURNACE
2
Ø
2. 54 cm (1")
3
5.08 cm (2")
4
BACK
FURNACE (OPPOSI TE SIDE O F THE BURNER)
1
7. 62 cm (3")
2.54 cm (1")
7. 62 cm (3")
PLENUM OR HORIZONTAL WARM-AIR DUCT WI THI N 6 f t. O F FURNACE
2
5. 08 cm (2")
5.08 cm (2")
5. 08 cm (2")
FURNACE
2
N/A
5.08 cm (2")
N/A
FLUE PIPE AROUND FLUE PIPE
22.86 cm (9")
22.86 cm (9")
22.86 cm (9")
FRO NT
FURNACE (BURNER SI DE)
1
45. 72 cm (18")
45.72 cm (18")
45. 72 cm (18")
1
These are horizontal dimensions
2
These are vertical dimensions
3
This dimension can be obt ained by using Horizontal Flow Base # HFB-101 or KLASB0701DET
4
This dimension can be obt ained by using Downflow Base # DFB-102 or KLASB0801DET
LOCATI ON
SIDES
TOP
16
Summary of Contents for AMP098SD
Page 17: ...Figure 9 Furnace dimensions 17 ...
Page 18: ...Figure 10 Wiring diagram 4 speed motor PSC 18 ...
Page 19: ...Figure 11 Wiring diagram variable speed motor ECM 19 ...
Page 20: ...Figure 12 Parts list with 4 speed motor PSC 20 B50064H ...
Page 22: ...Figure 13 Parts list with variable speed motor ECM 22 B50074H ...