OPTIMIZED IDLE INTEGRATION WITH
ParkSmart™
Optimized Idle Integration with ParkSmart™
When the driver initiates the O/I, the ParkSmart will operate in O/I mode as
follows:
• The ParkSmart runs unless the ParkSmart fan speed control knob is turned to the
"OFF" position. The fan speed control knob must be set at "1" or higher.
• The engine will periodically start and run for at least two hours to maintain
battery voltage then shut off. The ParkSmart will continue to operate during this
time.
• If O/I shuts down due to a fault in the O/I system, ParkSmart will continue to
operate until it is shut off by the driver or one of the automated fail-safes.
• The ParkSmart ON/OFF button and LED indicator on the parked HVAC control
module do not function when the vehicle is in O/I mode. When the vehicle is not
in O/I mode, the ParkSmart ON/OFF button and LED indicator operate
normally.
NOTE:
Vehicles equipped only with the ParkSmart Auxiliary HVAC System
have an additional bank of batteries separate and dedicated to the HVAC. If
Optimized Idle is also installed then all batteries are combined.
For more information see the Climate Control section of the Freightliner
Cascadia® Driver's Manual.
Optimized Idle User Manual
All information subject to change without notice.
25
DDC-SVC-MAN-0019
Copyright © 2016 DETROIT DIESEL CORPORATION