Safety
•
Safety Labels and Their Locations
SAMPLE
DETROIT RADIANT PRODUCTS COMPANY
21400 HOOVER ROAD - WARREN, MI
ELECTRIC INFRARED HEATER
FOR COMMERCIAL, INDUSTRIAL, AND OUTDOOR RESIDENTIAL USE.
FOR INDOOR OR OUTDOOR USE.
MADE IN USA.
(586) 756-0950
- www.drp-co.com
MODEL NO.
MW2-33S3-C12
INFRAROUGE A CHAUFFE AU ELECTRIQUE
SERIAL NUMBER
1902DETRXXXXXX 0001
VERSION
VOLTAGE
FREQUENCY
PHASE
MINIMUM MOUNTING HEIGHT
AMPERES (FLA)
MIN. MOUNTING ANGLE
MAX. MOUNTING ANGLE
REPLACEMENT LAMP(S):
THIS DESIGN COMPLIES WITH STANDARD(S):
TOTAL WATTAGE
09/18
240 VAC
50/60 Hz
Single or Three
8’
EL - 1082
STANDARD
ALTERNATE
N/A
0°
45°
UL 2021 - Edition 6 (revision 2018)
CSA C22.2 46-13 (R2018)
13.5
3750
Clearances to combustibles must be maintained at
all times in order to prevent the ignition of
combustible materials. In locations used for the
storage of combustible materials, signs must be
posted to specify the maximum permissible stacking height to
maintain the required clearances from the heater to the
combustibles. Signs must either be posted adjacent to the
heater’s thermostats or, in the absence of such thermostats, in a
conspicuous location. Clearances are provided on the heater’s
safety label and in the heater’s Installation, Operation, and
Maintenance manual. Product installation and operation must
comply with applicable standards, codes, and regulations. Post
this tag adjacent to the heater’s thermostat or controls before
operating the heater.
- INSTALLER: READ AND POST THIS NOTICE -
LL001-XM-07/18 (CDS)
This product can
expose you to
chemicals including
lead and carbon
monoxide, which are known to the
State of California to cause birth
defects or other reproductive harm.
For more information go to
www.P65Warnings.ca.gov.
WARNING
!
Avoid Serious Injury, Death, or Property Damage.
Maintain Clearances to Combustible to Prevent the Risk of Fire.
California Proposition 65
Safety Labels and Their Locations
It is important to provide warnings to alert individuals to potential hazards and safety actions. Signs
should state the hazards for the particular application and be legible to the building occupants. Consult
the factory or a factory representative for additional information on signage compliance.
Safety warning labels must be maintained on the infrared heater. Illustrations of the safety labels and
their locations are pictured below. When no longer legible, they must be replaced. Contact either your
local distributor or the product manufacturer for obtaining replacement signs or labels.
Top View
Rating Plate
F/N: LL001 - Clearance Safety Tag
(Affix adjacent to heater’s controller)
0°
45°
28 (712)
98 (2490)
28 (712)
4 (102)
30 (762)
30 (762)
9 (229)
10 (254)
98 (2490)
98 (2490)
CLEARANCES TO COMBUSTIBLES - Inches (Millimeters)
LLECL001b-xM-11/18 (CDS)
AVOID EQUIPMENT
FAILURE. Use 10AWG
supply wires suitable for
105°C or equivalent.
ÉVITEZ LES PANNES
D'ÉQUIPEMENT. Employer
10AWG des fils d'alimentation
adéquats pour 105°C.
Apply proper voltage.
Read and understand the installation, operating, and maintenance
instructions thoroughly before installing or servicing this equipment. Failure
to properly apply product may result in property damage, injury, or death.
SHOCK HAZARD. Disconnect all
supplies before working on any
circuit.
RISQUE D’ÉLECTROCUTION. Débrancher
toutes les alimentations avant d'exécuter des
travaux sur un circuit quelconque.
Heater
MUST be properly
grounded prior to operation.
HOT. Do not touch any part of
the heater while in operation.
Length Angle Front Behind End
Top
Below
FIRE HAZARD. Always maintain published clearances to
combustibles. In locations used for the storage of combustible
materials, signs must be posted.
DANGER D’INCENDIE. Toujours maintenir un dégagement
publié à combustibles. Dans les endroits utilisés pour le stockage
de matériaux combustibles, panneaux doivent être installés.
Mounting
Side
SIDE VIEW - 0°
END VIEW - 0°
End
End
END VIEW - 45°
Below
Front
Top
Behind
Side
Top
Side
Below
Heaters mounted on an angle between 0° and 45° must maintain clearances posted for 0° or 45°, whichever is greater.
MW2 Triple Element
24”
33”
46”
0°
45°
22 (559)
81 (2058)
22 (559)
4 (102)
22 (559)
22 (559)
6 (153)
10 (254)
81 (2058)
81 (2058)
MW2 Double Element
24”
33”
46”
0°
45°
9 (229)
29 (737)
9 (229)
4 (102)
6 (153)
6 (153)
6 (153)
10 (254)
42 (1067)
29 (737)
MW2 Single Element
24”
33”
46”
F/N: LLECL001b - Clearances to Combustibles Label
Electrical Label
(Located inside raceway)
F/N: LLECL004
Caution Label
NOTE: USE COPPER CONDUCTORS ONLY
CAUTION
- VERIFY SUPPLY VOLTAGE -
-VÉRIFIEZ LA TENSION D’ALIMENTATION-
DISCONNECT FROM ELECTRICAL SUPPLY
BEFORE SERVICING THIS HEATER.
THIS APPLIANCE MUST BE PROPERLY
GROUNDED TO THE ELECTRICAL SOURCE.
DÉBRANCHEZ DE L’ALIMENTATION ÉLECTRIQUE
AVANT L’ENTRETIEN DE CET APPAREIL DE CHAUFFAGE.
LLWEL02-1M-06/18 (CDS)
CET APPAREIL DOIT ÊTRE CORRECTEMENT
MIS À LA TERRE À LA SOURCE ÉLECTRIQUE.
ATTENTION: UTILISER DES CONDUCTEURS EN CUIVRE
LAMP NO. 1
L1
L2
LAMP NO. 2