![Detector CDT-404-2 Programming Manual Download Page 3](http://html1.mh-extra.com/html/detector/cdt-404-2/cdt-404-2_programming-manual_2487829003.webp)
Programming Manual
Conditioner CDT-404-2 / Touchscreen ETC1
English
Page 2/24
PROG404CDT-404-2-EN – Index B
1. Introduction
After a short presentation of the system possibilities, this guide will describe all adjustments
and settings of the conditioner
CDT-404-2.
With regard to installation and wiring, please refer to the Electrical installation manual
INSELE-CDT-404-2.
Do not hesitate to contact us for any additional information or in case of persistent
problems, a technician will be present to answer you either by email
:
or by phone +33 450 037 998.
The CDT-404-2 conditioner is designed to control one or two 404 broken tool detectors.
“Double direction” means that in the same cycle the detector can control by rotation in one
direction and then in the other direction.
This system performs several controls during the cycle to ensure the correct functioning of
the latter throughout its use.
The conditioner will make it possible to control the detectors and also to carry out controls
of different positions.
The first control is:
Broken tool control (Control 1 and Control 2)
: This control ensures the presence of the
tools at each cycle.
If the tool is broken, the detector will go further than the reference
position of the tool and the conditioner will then trigger a "Broken Tool" alarm and stop the
machine.
The second control is :
The presence of chips (Chips)
: This control allows to detect any clusters of chips around the
tool.
If the detector can not go to the tool reference position due to the chips, the
conditioner triggers a "Chip" alarm different from that of "Broken Tool".
The third control is :
The return to Origin (Origin):
This control consists in ensuring that the detector has returned
to its starting point at the end of the cycle
.
If the needle is trapped by a possible element (lubrication tube, passage of the needle
behind the tool, chips etc.) which will prevent its return, an alarm "Origin" will trigger and
stop the machine.