background image

Programming Manual 

Touch conditioner 

Broken tool detector type 404

 

 

 

www.detector-france.com 

English 

PROG404CDT-404-2-EN  – Index B 

 

Summary of Contents for CDT-404-2

Page 1: ...Programming Manual Touchscreen conditioner Broken tool detector type 404 www detector france com English PROG404CDT 404 2 EN Index B...

Page 2: ...ETC1 English Page 1 24 PROG404CDT 404 2 EN Index B 1 Introduction page 2 2 Identification of the conditioner page 3 3 Parameterization of the detector page 6 4 Reference by teaching page 11 5 Addition...

Page 3: ...nctioning of the latter throughout its use The conditioner will make it possible to control the detectors and also to carry out controls of different positions The first control is Broken tool control...

Page 4: ...ch screen The first Step is to identify the conditioner CDT 404 2 Note The blue light on the conditioner flashes it means that it is not recognized and can not be operated Flashing blue light the cond...

Page 5: ...tion page appears The settings on this page are empty because the identification has not yet been made To identify the conditioner on the touch screen simply open this page and press the ID button on...

Page 6: ...hat the detector is properly connected the needle must be moved from side to side to see the sensor value Detector input number Software version of the conditioner Identification number of detector in...

Page 7: ...w PRESS ICON The home page appears PRESS ICON Here is the setting page of the detector 1st Level Detector input number Each detector can be set differently This setting is present for each level Direc...

Page 8: ...he next cycle continues without stopping the machine The needle will touch the part that is present the Good Control output NO stays open and the Shutdown Machine output NC opens the machine stops at...

Page 9: ...erform the first control on the left and return to the origin to wait a second top control that will make the second control on the right with return to the origin at the end Note This parameter only...

Page 10: ...er affects the Control 1 Control 2 and Chip only alarms but not the Origin alarm The choice of the level is made using a drop down list Position The drop down list allows you to define where the detec...

Page 11: ...ting is used to lighten the display when a detector is not connected Activation This parameter also makes it possible not to make appear the second detector on the control page but in addition it will...

Page 12: ...t the reference procedure each time the machine is switched on again Note It is possible to set the system so that it does not require a reference every time the power is restored see paragraph Additi...

Page 13: ...tes at idle speed to the tool thus enabling the system to know the angular position of the tool tool reference When touching the tool the needle returns to its original position The reference procedur...

Page 14: ...PRESS ICON The home page appears PRESS ICON The configuration page General tab appears Language This setting is used to change the text language of the touch screen French English German Italian and...

Page 15: ...makes it possible to configure the state maintained or not of the output Good control between 2 top Control Stored When the control is OK the output Good Control closes and remains closed until the ne...

Page 16: ...The home page appears PRESS ICON The Datas page appears Type This parameter defines the communication protocol with the connected element via the SUB D9 COM on the back of the display Speed This param...

Page 17: ...tion of the settings LOCKING PRESS ICON The home page appears PRESS ICON The locking page appears Locking Locking limits access to all parameters Once locked only access to the control page is possibl...

Page 18: ...Conditioner CDT 404 2 Touchscreen ETC1 English Page 17 24 PROG404CDT 404 2 EN Index B Here is lock code change procedure PRESS ICON PRESS THE BOX This message appears PRESS THE BUTTON This message app...

Page 19: ...1 English Page 18 24 PROG404CDT 404 2 EN Index B PRESS THE BUTTON This message appears This message appears PRESS THE BUTTON Enter the original code 0000 with the num ric keypad Validate by Enter Ente...

Page 20: ...ETC1 English Page 19 24 PROG404CDT 404 2 EN Index B This message appears PRESS THE BUTTON This message appears PRESS THE BUTTON The lock code has been changed Confirm the new code by entering it a se...

Page 21: ...Conditioner CDT 404 2 Touchscreen ETC1 English Page 20 24 PROG404CDT 404 2 EN Index B Here is the lock procedure PRESS ICON PRESS THE BOX This message appears PRESS THE BUTTON PRESS THE BUTTON Press t...

Page 22: ...tioner CDT 404 2 Touchscreen ETC1 English Page 21 24 PROG404CDT 404 2 EN Index B The screen is now locked When you want to enter in the menu the code will be requested Enter the code with the numeric...

Page 23: ...the menu the code is requested By entering the code you access the menu but in any case you unlock the screen permanently When you return to the control page and want to enter in the menu again the co...

Page 24: ...Programming Manual Conditioner CDT 404 2 Touchscreen ETC1 English Page 23 24 PROG404CDT 404 2 EN Index B The screen is now unlocked Enter the code with the numeric keypad Validate by Enter...

Page 25: ...s the following parameters Detector Rotation direction Anticlockwise default value Control Mode Presence of tool default value Number of control 1 default value Micro Tool No default value Tolerance l...

Page 26: ...r france com Manufacturer Detector France 36 route des lacs PAE des Jourdies 74800 Saint Pierre en Faucigny T l 33 0 450 037 998 Fax 33 0 450 036 792 Email commercial detector france com PROGCDT 404 2...

Reviews: