keepall the instructions given under all  circumstances. 

3.1

 

Advice for user

 

Avoid positioning any objects and/or appliances that could be damaged by water leaks beneath the 
water heater.

 

Should you not use any water for an extended period of time, you should:

 

 

disconnect the appliance from the electrical supply by switching the external  switch“OFF”.

 

 

turn off the plumbing circuit taps.

 

 

hot water at above 50°C flowing out of the taps at the point of use could cause serious scalds or even 

death from  burns.  Children,  the  disabled and the  elderly  are  more  exposed to  the  risk  of  burns.  It  is 
strictly forbidden for the user to perform any routine or extraordinary  maintenance.

 

3.2

 

Starting

 

To  turn  on  the  appliance  is  enough  to  put  into“ON”  position  the  bipolar  switch  (see  electrical 
connection)

 

3.3

 

Temperature adjustment

 

Models with external thermal regulation are equipped with an adjustment knob situated onto the plastic 
cap.

 

The customer can adjust, as his preference, the temperature in order to get the best pleasure.

 

We  suggest a regulation below the maximal set in order to achieve the best performance with o good  
level of efficiency and good comfort. Models with no thermostat control knobs have automatic water 
temperature preset by the Manufacturer 65°C +/- 5°C 

4.

 

MAINTENANCE INSTRUCTION (for competent persons)

 

WARNING. 

Follow  the  general  warnings and the  safety  norms  listed at  the  beginning  of  the  text  and 

keep all the instructions given under all circumstances.

 

Before execute any type of operation (maintenance, cleaning,…) switch off the    appliance.

 

All  intervention  must  be  performed  by  qualified  personnel  only.  For  operation  on  thermostat 
remove the  plastic cap after electrical disconnection. For operation on resistance drain completely 
the appliance (see respective  paragraph).

 

4.1

 

Periodic  maintenance

 

In order to obtain the best performance from the appliance is advisable to descale the resistance every 
year. The operation can be carried out crumbling the limescale from the cover of the resistance. Take 
care to not damage it.

 

The magnesium anode must be substitute every 2 years (see warrantee conditions). In order to remove 
it  is  necessary  to  remove  the  resistance.  The  pressure-relief  device  is  to  be  operated  regularly  to 
remove lime deposits and to verify that it is not  blocked.

 

4.2

 

Draining of the appliance

 

In order to drain the appliance proceed as follow:

 

1.

 

Switch off the electrical  connection

 

2.

 

Turn on the tap of inlet cold water

 

3.

 

Turn on the tap of hot water

 

4.

 

Turn on the drain tap if equipped during installation, otherwise remove the safety valve for undersink 
models is necessary to overturn the appliance. 

4.3

 

Bipolar safety reactivation

 

The  appliance  is  equipped  with  a  thermostat  with  safety  limiting  device  according  to  IEC-EN 
regulations. In case of abnormal overheating of the water, a thermal safety switch shuts off the  

 

Summary of Contents for BAMEMA150-D

Page 1: ...140 350 180 350 285 130 Manuel d installation et d utilisation Installatie en gebruiksaanwijzing Operation and Installation Manual BAMEMA150 D CHAUFFE EAU LECTRIQUE MURAL MAILL 150L GE MAILLEERD ELEKT...

Page 2: ...personnes de qualification similaire afin d viter un danger Le dispositif limiteur de pression doit tre mis en fonctionnement r guli rement afin de retirer les d p ts de tartre et de v rifier qu il n...

Page 3: ...on III La l gende du sch ma lectrique est rapport e ci dessous R r sistance lectrique S1 S2 contacts thermostats TS dispositif de s curit du thermostat TR contact activ L N ligne d alimentation SP t m...

Page 4: ...tance il faut vidanger le chauffe eau L anode de magn sium doit tre remplac e tous les 2 ans conform ment aux conditions de la garantie Pour l enlever il y a lieu au pr alable de d monter la r sistanc...

Page 5: ...igd is moet deze door de fabrikant de dienst na verkoop of door personen met gelijkaardige kwalificaties worden vervangen om gevaar te vermijden De drukbegrenzer moet regelmatig worden ingeschakeld om...

Page 6: ...of de spanning van het netwerk conform is aan de spanning die is aangeduid op het typeplaatje In het elektrisch voedingscircuit van de boiler moet ook een inrichting worden gemonteerd die de onderbrek...

Page 7: ...erhoudswerken moeten worden uitgevoerd door gekwalificeerd personeel Alvorens onderhoudswerken uit te voeren koppelt u het toestel los van het elektrisch netwerk Om toegang te krijgen tot de elektrisc...

Page 8: ...ls aangeduid in de vorige paragrafen of controleert u op de thermostaat na deze te hebben gedemonteerd de continu teit van de contacten op de terminals en de faston verbindingen Als dit alles in orde...

Page 9: ...at the beginning of the text and keep all the instructions given under all circumstances The range of the water heaters includes models designed for being fitted IN A VERTICAL OR HORIZONTAL POSITION...

Page 10: ...e electrical circuit supplying the appliance must have an in built device ensuring the splitting of allterminals poles under conditions ofsuper voltagecategory III The connection must be done accordin...

Page 11: ...ARNING Follow the general warnings and the safety norms listed at the beginning of the text and keep all the instructions given under all circumstances Before execute any type of operation maintenance...

Page 12: ...he water and electrical connections are as specified in the relative paragraphs or make sure of the continuity of the phases between the clamps and the relative fastons on the thermostat after taking...

Page 13: ...13 www detandt com...

Reviews: