background image

 
 

www.detandt.com 

 

 
 
   GENERAL REMARKS 

A careful reading is recommended in order to achieve the best performance of the   product.

 

The  installation  is  in  charge  of  the  customer,  the  manufacturer  is  not  responsible  for  the  damages 
caused  by  wrong  installation  and  for  not  following  instructions  contained  within  this  manual,  in 
particular:

 

 

the electric connection has to be in compliance with the relative paragraph

 

 

the safety valve supplied with the appliance has not to be tempered with or substituted

 

 

the installation has to be carried out by qualified professional

 

The  device  can  be  used  by  children  aged  over  8  years  old  and  persons  with  reduced  physical, 
sensory  or  mental  capabilities,  or  lack  of  experience  or  knowledge  required,  provided  under 
supervision  or  after  the  same  has  received  instructions  relating  to  ‘ensure  safe  operation  and 
understanding  of  the  dangers  inherent  in  it.  The  cleaning  and  maintenance  intended  to  be 
performed by the user should not be carried out by children without supervision.

 

    

The children must be supervised in order to avoid they play with the appliance. 
This appliance complies with the provisions of EEC Directives.

 

 

1.

 

INSTALLATION INSTRUCTIONS (for the installer)

 

WARNING : Follow the general warnings and the safety norms listed at the beginning  of 
the text and keep all the instructions given under all   circumstances.

 

The range of the water heaters includes models designed for being fitted IN A VERTICAL 
OR HORIZONTAL POSITION  (fig.1).

 

1.1

 

Fasten to the wall

 

The appliance is fixed to a wall via the mounting bracket attached to the unit’s body. Two hook are 
used for suspending the appliance. We recommend to use hooks of suitable dimensions for the type of 
wall (not included in the mounting set). Hook the water heater to the bracket and pull it downwards 
to make sure it has been fastened correctly.

 

1.2

 

Water connection

 

-

 

Water inlet: marked with blue  ring.

 

-

 

Water outlet: market with red ring.

 

The  appliance  is equipped with a safety  valve  against  overpressure  adjusted at  the  value  of  0,8  MPa  
(8  bar) (fig. 3).

 

Connect inlet tube with blue collar a “T” piece union, hence, connect on one side a tap for draining the 
appliance that can only be operated with the use of a tool ; on the other side screw the safety valve . 
Don’t force the safety valve  otherwise  you can damage it. Connect the safety valve to the  cold main 
tube by flexible pipe.

 

 

WARNING: 

for  those  nations  that  have  taken  on  European  norm  EN1487:2000,  the  pressure 

safety device provided with the product does not comply with national    norms.

 

According to the norm, the device must have a maximum pressure of 0.7MPa (7 bar) and have at least: 
a cut-off valve, a control mechanism for the non-return valve, a safety valve and a water pressure shut- 
 

Summary of Contents for BAMEMA150-D

Page 1: ...140 350 180 350 285 130 Manuel d installation et d utilisation Installatie en gebruiksaanwijzing Operation and Installation Manual BAMEMA150 D CHAUFFE EAU LECTRIQUE MURAL MAILL 150L GE MAILLEERD ELEKT...

Page 2: ...personnes de qualification similaire afin d viter un danger Le dispositif limiteur de pression doit tre mis en fonctionnement r guli rement afin de retirer les d p ts de tartre et de v rifier qu il n...

Page 3: ...on III La l gende du sch ma lectrique est rapport e ci dessous R r sistance lectrique S1 S2 contacts thermostats TS dispositif de s curit du thermostat TR contact activ L N ligne d alimentation SP t m...

Page 4: ...tance il faut vidanger le chauffe eau L anode de magn sium doit tre remplac e tous les 2 ans conform ment aux conditions de la garantie Pour l enlever il y a lieu au pr alable de d monter la r sistanc...

Page 5: ...igd is moet deze door de fabrikant de dienst na verkoop of door personen met gelijkaardige kwalificaties worden vervangen om gevaar te vermijden De drukbegrenzer moet regelmatig worden ingeschakeld om...

Page 6: ...of de spanning van het netwerk conform is aan de spanning die is aangeduid op het typeplaatje In het elektrisch voedingscircuit van de boiler moet ook een inrichting worden gemonteerd die de onderbrek...

Page 7: ...erhoudswerken moeten worden uitgevoerd door gekwalificeerd personeel Alvorens onderhoudswerken uit te voeren koppelt u het toestel los van het elektrisch netwerk Om toegang te krijgen tot de elektrisc...

Page 8: ...ls aangeduid in de vorige paragrafen of controleert u op de thermostaat na deze te hebben gedemonteerd de continu teit van de contacten op de terminals en de faston verbindingen Als dit alles in orde...

Page 9: ...at the beginning of the text and keep all the instructions given under all circumstances The range of the water heaters includes models designed for being fitted IN A VERTICAL OR HORIZONTAL POSITION...

Page 10: ...e electrical circuit supplying the appliance must have an in built device ensuring the splitting of allterminals poles under conditions ofsuper voltagecategory III The connection must be done accordin...

Page 11: ...ARNING Follow the general warnings and the safety norms listed at the beginning of the text and keep all the instructions given under all circumstances Before execute any type of operation maintenance...

Page 12: ...he water and electrical connections are as specified in the relative paragraphs or make sure of the continuity of the phases between the clamps and the relative fastons on the thermostat after taking...

Page 13: ...13 www detandt com...