9
www.detandt.com
GENERAL REMARKS
A careful reading is recommended in order to achieve the best performance of the product.
The installation is in charge of the customer, the manufacturer is not responsible for the damages
caused by wrong installation and for not following instructions contained within this manual, in
particular:
•
the electric connection has to be in compliance with the relative paragraph
•
the safety valve supplied with the appliance has not to be tempered with or substituted
•
the installation has to be carried out by qualified professional
The device can be used by children aged over 8 years old and persons with reduced physical,
sensory or mental capabilities, or lack of experience or knowledge required, provided under
supervision or after the same has received instructions relating to ‘ensure safe operation and
understanding of the dangers inherent in it. The cleaning and maintenance intended to be
performed by the user should not be carried out by children without supervision.
The children must be supervised in order to avoid they play with the appliance.
This appliance complies with the provisions of EEC Directives.
1.
INSTALLATION INSTRUCTIONS (for the installer)
WARNING : Follow the general warnings and the safety norms listed at the beginning of
the text and keep all the instructions given under all circumstances.
The range of the water heaters includes models designed for being fitted IN A VERTICAL
OR HORIZONTAL POSITION (fig.1).
1.1
Fasten to the wall
The appliance is fixed to a wall via the mounting bracket attached to the unit’s body. Two hook are
used for suspending the appliance. We recommend to use hooks of suitable dimensions for the type of
wall (not included in the mounting set). Hook the water heater to the bracket and pull it downwards
to make sure it has been fastened correctly.
1.2
Water connection
-
Water inlet: marked with blue ring.
-
Water outlet: market with red ring.
The appliance is equipped with a safety valve against overpressure adjusted at the value of 0,8 MPa
(8 bar) (fig. 3).
Connect inlet tube with blue collar a “T” piece union, hence, connect on one side a tap for draining the
appliance that can only be operated with the use of a tool ; on the other side screw the safety valve .
Don’t force the safety valve otherwise you can damage it. Connect the safety valve to the cold main
tube by flexible pipe.
WARNING:
for those nations that have taken on European norm EN1487:2000, the pressure
safety device provided with the product does not comply with national norms.
According to the norm, the device must have a maximum pressure of 0.7MPa (7 bar) and have at least:
a cut-off valve, a control mechanism for the non-return valve, a safety valve and a water pressure shut-
Summary of Contents for BAMEMA150-D
Page 13: ...13 www detandt com...