NOTE
Sensor cross sensitivity has not been verified by FMRC.
NOTE
FMRC Approval of the 4 to 20 ma input does not include or imply approval of the gas detection apparatus such
as sensors, transmitters, or devices connected to the system. In order to maintain FMRC Approval of the
system, all 4 to 20 ma gas detection instruments connected to the input must also be FMRC Approved.
MODEL EQ2200DCUEX SERIES DIGITAL COMMUNICATION UNIT
WITH MODEL CGS SERIES COMBUSTIBLE GAS SENSOR
• Explosion-proof for Class I, Division 1, Groups B, C, and D Hazardous (Classified) Locations per FM 3615.
• Dust ignition-proof for Class II, Division 1, Groups E, F, and G, Class III Hazardous (Classified) Locations per FM
3615. (For use with Sensor Separation Kit)
• Non-incendive for Class I, Div. 2, Groups A, B, C, and D; Temperature Code T4A Hazardous (Classified) Locations
per FM 3611.
• Non-incendive for Class II, Div. 2, Groups F and G; Class III; Temperature Code T4A Hazardous (Classified)
Locations per FM 3611. (For use with sensor separation kit.)
• EQ22EMDCUEX non-incendive for Class I, Div. 2, Groups A, B, C and D; Temperature Code T4A Hazardous
(Classified) Locations per FM 3611.
• Enclosure Rating NEMA Type 4X per ANSI/NEMA 250 (For use with Sensor Separation Kit).
• Operating Temperature Limits –40°C to +75°C.
• Storage Temperature Limits –55°C to +85°C.
• Relative Humidity Range: 5 to 95% RH.
• Performance verified for 0 to 100% LFL methane-in-air atmospheres per FM 6310/6320. Accuracy: ±3% LFL from
0 to 50% LFL, ±5% LFL from 51% to 100% LFL.
NOTE
The high temperature characteristic has NOT been FMRC verified above 75°C.
NOTE
Detector Electronics combustible gas detection K factors are not FMRC verified.
SENSOR SEPARATION KIT
226365-106
Combustible, Aluminum, 3/4 inch NPT, 4 Position Connector
226365-113
Combustible, Aluminum, 3/4 inch NPT, Wiring Harness
226365-104
Toxic, Aluminum, 3/4 inch NPT
• Explosion-proof for Class I, Division 1, Groups B, C, and D Hazardous (Classified) Locations per FM 3615.
NOTE
Ensure sensor hazardous (classified) location rating is applicable for the intended use.
95-8470
A-7