Troubleshooting
EN
26 / 28
07/2020
Number
Description
Procedure
I210
Invalid Pset selected
1- The selected Pset does not match the Pset selectable
in the Assembly Process.
I211
Invalid trigger configuration
1- The tool connected to the system is not equipped
with the trigger required by the trigger configuration.
2- Adjust your trigger configuration to the tool or
change the tool according to the trigger configuration.
I224
IGBT too hot
1- Power electronics too warm.
2- Let the system cool down.
I251
No Pset selected
1- No Pset selected.
2- Select a Pset.
I270
Time settings
1-Invalid Time setting|2-Check Pset settings with cor-
rect time value settings
W010
Tool calibration expired
1- The tool calibration date has expired.
2- A tool calibration needs to be done to ensure the
measurement accuracy.
W028
Battery tool version error
1 - Battery tool version and system version are not
compatible.
W030
The battery is low.
1- The battery is low.
2- Recharge the battery.
W033
Tool time error
1- The tool time is not set correctly. The tightening re-
sults will not be time stamped.
2- Connect the tool to the system to set date and time.
W036
Tool memory full
1- The tool memory is full.
2- Connect the tool to the system to empty the mem-
ory.
W062
Overload of torque
1- Overload of the torque (could be a rehit).
2- Check the tool cable is not damaged.
W212
Result not stored
1- It is not possible to store the tightening result in the
system.
2- Contact your Desoutter representative for support.
W216
Current high
1- Maximum current exceeded.
2- Contact your Desoutter representative for support.
W267
Result transfer error
Result transfer error.
E007
Motor too hot
1- Tool is locked because the maximum motor temper-
ature has been reached.
2- Tool will remain locked until the motor temperature
comes back to its normal value.
E008
Tool angle fault
1- Problem detected with the tool angle sensor.
2- The tool needs maintenance.
E009
Tool invalid parameters
1- Check the tool compatiblity.
2- The tool memory cannot be read or is invalid.
3- The tool needs maintenance. If the problem occurs
again, contact your Desoutter representative for sup-
port.
E012
Tool EEPROM error
1- The tool memory cannot be read or is invalid.
2- The tool needs maintenance. If the problem occurs
again, contact your Desoutter representative for sup-
port.
E018
Torque out of range !
1- The target torque value is above the tool maximum
torque.
2- Check Pset settings with tool characteristics.
E029
The battery is empty.
1- The battery back is discharged. The tool cannot
tighten.
2- Recharge the battery pack.
E031
Battery error
1- Abnormal battery voltage. The tool cannot tighten.
2- Recharge the battery pack. If the problem occurs
again, replace the battery pack.