Desoutter EABC15-900-eLINK Product Instructions Download Page 23

EN

Service

07/2020

23 / 28

Calibration via tool display

The calibration procedure is recommended to compensate for any possible drift of the tool torque or after each
change of tool element.

This function is set in the "Maintenance" menu.

1.

Enter the Maintenance password in the "Configuration" menu.

2.

Insert a torque transducer in line with the tool and connect it to any measuring unit from the Desoutter range.

3.

Go to "Maintenance/Calibration".
Select the number of tightenings required to execute the calibration and press OK.
Run a Pset the number of times already configured (at max. torque and with an angle above 180° (at low
speed)).
Go on with other tightenings by pressing the trigger.

4.

The average torque value is displayed in white.
On the line below, enter the average torque value measured by the measuring unit (± 20 % vs the tool nominal
torque are allowed).

5.

Use the left/right buttons to increase or decrease the value.

Press OK and save your data.

Calibration with eDOCK and CVIMONITOR

The calibration procedure is recommended to compensate for any possible drift of the tool torque or after any change
of tool element.

In the manual mode, the standard procedure is executed.
Measurements and values are typed manually by the operator.

The equipment required is as follows:

• Tool equipped with a torque transducer in line

• CVIMONITOR

• Delta measuring unit

Click this icon.

Click 

Tool calibration

.

The standard procedure is as follows:

1.

Select the Pset to execute.

2.

Select the number of tightenings to perform (5 by default, 50 as a maximum).
According to the test bench use, the tightening may be preceeded by a loosening.

3.

Click "Start calibration".

4.

Start performing the first loosening / tightening operation. The operation must be successful.

5.

At the end of each operation, enter the torque value on the measuring unit.

6.

When all operations are performed, a new calibration value is displayed.

Checking before putting back into service

Prior to putting the equipment back into service, check that its main settings have not been modified and that the
safety devices work properly.

Advanced tool maintenance with ACCESS KEY

Launch CVIMONITOR.

To activate the screens, you need to have an ACCESS KEY USB stick with the right profile (configured with the
Desoutter CVIKEY software).
If not, contact your CVIKEY manager for support.

Summary of Contents for EABC15-900-eLINK

Page 1: ...NK 6151660500 EABC26 560 eLINK 6151660510 EABC32 410 eLINK 6151660520 EABC45 330 eLINK 6151660530 EABC50 450 eLINK 6151660540 EABC60 370 eLINK 6151660550 EABC75 300 eLINK 6151660560 EABC95 240 eLINK 6...

Page 2: ...e the tool 13 How to change network parameters 16 How to set up Psets and Assembly Processes 17 Operating Instructions 17 How to use the tool 17 Service 21 Tool information from tool display 21 Firmwa...

Page 3: ...07 2020 3 28 What if the tool is locked 25 List of user infos related to the tools 25...

Page 4: ...pressed in time operation hours or otherwise The product warranty relies on the correct use maintenance and repair of the tool and its component parts Damage to parts that occurs as a result of inadeq...

Page 5: ...2 46 45 330 3 8 35 12 51 50 450 3 8 35 12 51 60 370 1 2 40 12 57 75 300 1 2 45 18 60 95 240 1 2 45 18 60 EABC e LINK mm Model L A B 15 900 496 46 46 26 560 496 46 46 32 410 496 46 46 45 330 506 46 46...

Page 6: ...nutrunners e LINK models can be equipped with a barcode reader or a tracker They are hand held by the operator and powered by a Desoutter battery pack On delivery the tool display is protected by a p...

Page 7: ...tery footprint 5 Display 6 Programming buttons 7 Reverse button 8 Communication module 1 eLINK module 2 Front light Technical data Voltage V 36 V Output drive Model Type EABx 15 900 Sq 1 4 EABx 26 560...

Page 8: ...ge ft lb Model Min Nominal Max EABx 15 900 3 69 9 59 11 06 EABx 26 560 3 69 17 70 19 18 EABx 32 410 5 16 22 13 23 60 EABx 45 330 6 64 29 50 33 19 EABx 50 450 6 64 33 19 36 88 EABx 60 370 7 37 40 57 44...

Page 9: ...s given without the battery pack Storage and use conditions Storage temperature 20 to 70 C 4 to 158 F Operating temperature 0 to 45 C 32 to 113 F Storage humidity 0 95 RH non condensing Operating humi...

Page 10: ...bit 9 Mbit 11 Mbit 12 Mbit 18 Mbit 24 Mbit 36 Mbit 48 Mbit 13 Mbit MCS1 19 5 Mbit MCS2 26 Mbit MCS3 39 Mbit MCS4 52 Mbit MCS5 58 5 Mbit MCS6 65 Mbit MCS7 6 5 Mbit MCS0 Link adaptation True RSSI Receiv...

Page 11: ...x x x 104 x x x x 108 x x x x 112 x x x x 116 x x x x 120 N A x x N A 124 N A x x N A 128 N A x x N A 132 x x x x 136 x x x x 140 x x x x 149 U NII 3 x x N A N A 153 x x N A N A 157 x x N A N A 161 x...

Page 12: ...re a longer service life of the battery pack Unplug the battery pack when the tool is not used Do not leave the battery pack on the charger when the charger power supply is off How to connect the tool...

Page 13: ...utton Left button Validate Save Quit Pset The sound is disabled The sound is enabled The battery pack is full The battery pack is low Additional icons and buttons Results and curves are stored in the...

Page 14: ...displayed Go to the main screen Press this button during 2 seconds Press this button to reach Configuration Go to Set password then Pset password use the buttons to enter a figure from 0 to 999 save a...

Page 15: ...l delivery the Reverse function is disabled Go to CVI CONFIG to set up reverse settings How to visualize network parameters Go to the tool display Press this button during 2 seconds Press this button...

Page 16: ...CONFIG Configuration manual available at https www desouttertools com resource centre Instructions for use The tool behaviour is the same as an EABA or EPBA tool 6 Psets are available Refer to the Pro...

Page 17: ...be changed at any time The minimum to run the tool is 1 Pset containing 1 step An Assembly Process is commonly called AP and is shown by this icon The Assembly Process available in products and syste...

Page 18: ...ect the displayed Assembly Process The number is now in blue Once the Assembly Process is selected and the tool ready the Pset number turns green Press the trigger to start the process Starting the to...

Page 19: ...process is done results are displayed Torque and angle values Batch count Ellipse The ellipse represents the batches In this example 3 tightenings out of 4 are completed How to interact on the Assembl...

Page 20: ...he torque reaction on the operator On tool delivery this feature is disabled Go to CVI CONFIG to enable the feature How to wake up the tool The tool display switches off automatically after 2 minutes...

Page 21: ...k indicates the reading is successful Tool test with CVIMONITOR Click this icon Click Tool test Click Start tool test LEDs start blinking Press the triggers the reverse button Click Start audio test T...

Page 22: ...tightenings refer to the table below depending on which occurs sooner Maintenance frequency 500 000 tightenings Service alarm on tool display An alarm can be displayed when service is required This i...

Page 23: ...le drift of the tool torque or after any change of tool element In the manual mode the standard procedure is executed Measurements and values are typed manually by the operator The equipment required...

Page 24: ...un during around 1 minute and will stop automatically Click Stop motor align to stop the process before the end Release the trigger Declaring fixed accessories A fixed accessory mounted on a tool must...

Page 25: ...tart the tool with no mechanical constraints If the problem occurs again contact your Desoutter representative for support I026 Tool maintenance alarm n1 1 The tool tightening counter has been reached...

Page 26: ...que 1 Overload of the torque could be a rehit 2 Check the tool cable is not damaged W212 Result not stored 1 It is not possible to store the tightening result in the system 2 Contact your Desoutter re...

Page 27: ...45 Abnormal battery voltage 1 Check the battery pack 2 This error can be due to charger malfunction or end of life battery E047 Battery is too low 1 Check the battery pack 2 If the problem occurs agai...

Page 28: ...cles Off Road General Industry Desoutter offers a comprehensive range of Solutions tools service and projects to meet the specific demands of local and global customers in over 170 countries The compa...

Reviews: