8
Blade Clamp Operation
Assembly:
•
Using the spanner provided, remove the clamp nut on the end of the oscillating
shaft in an anti clockwise direction.
•
Insert the blade onto the oscillating shaft, and locate the splined hole in the blade
over the spline on the shaft.
•
Replace the clamp nut and tighten
Removal:
•
Using the spanners provided, remove the clamp nut on the end of the oscillating
shaft in an anti clockwise direction.
•
Remove the blade.
•
Replace the clamp nut.
Refer to the diagram below.
Conditions for Transport & Storage
Temperature:
-20ºC to +40ºC
Relative Humidity:
90% maximum.
Atmospheric Pressure:
1.5 atmospheres maximum
.