Operation
EN
10 / 24
06/2020
• in.lb
• kg.m
• kg.cm
• oz.in
• dNm
To change the torque unit, go to the main screen.
Press this button during 2 seconds.
Press this button to reach
Configuration
.
Go to
Torque unit
, use the buttons to select the torque unit and validate.
How to set up the reverse mode
Go to the main screen.
Press this button during 2 seconds.
Press this button to reach
Configuration
.
Go to
Reverse
.
Use the buttons to enable or disable the feature.
Select the reverse mode (alternate or once), save and validate.
How to set up the Pset
There are 6 pre-defined Psets in the tool.
Parameters are already configured according to the tool characteristics.
Check that the Pset password is disabled.
The green padlock is displayed on the top line.
Go to the main screen.
Press this button during 2 seconds.
Press this button to reach
Pset
.
Use the buttons to navigate, save and validate.
If no action is done, the display returns to the main screen after 15 seconds and the changes will not be saved.
Pressing the trigger at that stage will cancel all modifications done.
Parameter
Description
Thread
Selection of the thread direction of the screw.
CW: when operating in forward, the tool rotates clockwise.
CCW: when operating in forward, the tool rotates counter-
clockwise.
Tightening strategy
Torque control with angle monitoring
or
Angle control with angle monitoring.
Target torque
The torque value to reach.
Target angle
The angle value to reach.
Min./max. torque
Torque values which define the min./max. torque tolerances.
Min./max. angle
Angle values which define the min./max. angle tolerances.
Abort angle
Safety angle value to stop the tool.
Abort torque
Safety torque value to stop the tool.