Right hand thread
When reassembling:
Apply the recommended glue.
Tighten to the required torque.
Lubricate with the required grease or oil. Do not apply too much grease on gears or bearings; a thin coat shall be
sufficient.
Instructions for transducerized tools
• Do not damage the wires when pulling out the connectors.
• Do not pull out the torque transducer wires.
• Ensure that wires are not crushed.
Preventive Maintenance
Recommendations
Overhaul and preventive maintenance are recommended at regular intervals once per year or after a maximum num-
ber of tightenings (refer to the table below) depending on which occurs sooner.
Maintenance frequency
500,000 tightenings
Service alarm on tool display
An alarm can be displayed when service is required.
This icon is displayed.
One of the service levels is displayed (see below). When no service is required, "none" is displayed.
A sound is heard.
It is possible to set 3 service levels:
Level
Number of tightenings
Service level
1
25 000
Calibration
2
250 000
Intermediate
(for heavy duty applications only)
3
500 000
Standard
Go to the main screen.
Press this button during 2 seconds.
Press this button to reach
Maintenance
.
Go to
Tool
, then
Service alarm
, select a level, save and validate.
Once the service is performed, reset the indicators.
Go to the "Maintenance/Service alarm" menu and press OK.