![Desmi NSL 100-215 Operation And Maintenance Instruction Download Page 48](http://html1.mh-extra.com/html/desmi/nsl-100-215/nsl-100-215_operation-and-maintenance-instruction_2487038048.webp)
INSTALLATION
DESMI Pumping Technology A/S
Tagholm 1
9400 Nørresundby
– Denmark
Tlf. nr.: +45 96 32 81 11
Fax +45 98 17 54 99
E-mail: [email protected]m
46
protection of the pump and motor unit.
If the motor weighs more than say two times the pump (often the case for e.g. small vertical DESMI
NSL pumps with 2-pole motor running say 2980 or 3570 rpm) it is normally better to mount the lateral
supports at the motor
’s lifting eye bolt holes (i.e. near the center of gravity for the motor).
Examples of DESMI vertical pumps with lateral supports bolted onto motor mounting flange (i.e. re-
using existing bolt holes) are shown as below:
Figure 5-3: Examples of DESMI vertical pumps with lateral supports
DESMI recommends the following values for protective settings:
Location
Vibration alarm level (mm/s)
Vibration trip level(mm/s)
Pump
>7
>10
Motor (drive end)
>7
>10
Motor (non drive end)
>10
>15