![Desmi NSL 100-215 Operation And Maintenance Instruction Download Page 100](http://html1.mh-extra.com/html/desmi/nsl-100-215/nsl-100-215_operation-and-maintenance-instruction_2487038100.webp)
ASSEMBLING PUMP SET
DESMI Pumping Technology A/S
Tagholm 1
9400 Nørresundby
– Denmark
Tlf. nr.: +45 96 32 81 11
Fax +45 98 17 54 99
E-mail: [email protected]m
98
3. For Ø330/415/418/465/525, fix the rear cover to
the motor bracket mounted with electric motor.
Assembly the shaft seal (10) .
4. Fit the sunk key in the shaft and lead the
impeller towards the shoulder of the shaft.
Secure the impeller with washers (7 and 8) and
a nut (Ø215/265/418) or a set screw
(Ø330/415/465/525).
NOTE: Take care that the ring at the end of the shaft seal spring locates in the recess of the
impeller.
Summary of Contents for NSL 100-215