![Design Aeris Reference Manual Download Page 23](http://html1.mh-extra.com/html/design/aeris/aeris_reference-manual_2486768023.webp)
23
Delayed Violation # 2
- Deco Stop between 60 FT (18 M) and 70 FT (21 M) is required.
Upon being alerted of this condition, you would need to ascend to just deeper than 60 FT
(18 M), staying as close to 60 FT (18 M) as possible without causing the Total Ascent Time
display to flash. When the required Stop Depth indicates 50 FT (15 M), etc., you can then
ascend to, but no shallower than those depths and continue decompressing.
The Dive computer cannot accurately calculate Deco times for Stop Depths much greater
than 60 FT (18M) and offers no indication of how much time spent underwater would re-
sult in the need for a greater Stop Depth.
Delayed Violation # 3
- exceeding Max Operating Depth (MOD).
Upon being alerted of this condition, Current Depth will not be displayed until ascent is
made to a depth shallower than the MOD. Max Depth will not be displayed for the re-
mainder of that dive.
Violation Gauge Mode (VGM)
Five minutes after reaching the surface from a dive in which a Delayed Violation occurred,
operation will enter VGM.
It will also enter VGM during a dive, if a Deco Stop of 70 FT (21M) or greater is required.
This situation would be preceded by entering Delayed Violation. The Dive computer
would then operate only as a digital depth gauge/timer without any nitrogen or oxygen
calculations or displays.
(continued on page 24)