background image

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-3069

 Page 3 of 7

© 2016 DESCO INDUSTRIES, INC.

Employee Owned

Features and Components

B

Figure 7.  Combo Tester features and components

A

C

D E

F

G

A.  6-9VDC Power Jack:

 Connect the 

98256

 or 

98257

 

power adapter (sold separately) here to power the 

Combo Tester.

B.  Test Result LEDs:

 Displays the test results.

C.  Foot Plate Jack:

 Connect the banana plug terminal 

of the foot plate cord here and the other end to the 

pedestal (

19282

) or stainless steel foot plate (

19283

98273

).

D.  Rocker Switch:

 Toggle to the left when performing 

a footwear test.  Toggle to the right when performing a 

wrist strap test.

E.  Single-Wire Wrist Strap Jack:

 Insert your 

single-wire wrist cord here to test your wrist strap.

F.  Test Switch:

 Push down and hold your finger here 

to perform a test.

G.  Low Battery LED:

 Illuminates when the battery 

power is low and needs to be replaced.

98254

 STAND AND FOOT PLATE

1  Foot Plate

1 Pedestal

1  Foot Plate Cord, 5 inches

3  Button Head Screws, 1/4-20 x 3/4”

1  Allen Wrench, 5/32”

1  Flat Head Screw, 8-32 x 5/8”

1  Knurled Nut, 8-32

1  Black Cap

1 Poster

Figure 5.  Desco 

98254

 Stand and Foot Plate

98273

 STAINLESS STEEL FOOT PLATE

1  Stainless Steel Foot Plate

1  Foot Plate Cord, 6 feet

Figure 6.  Desco 

98273

 Stainless Steel Foot Plate

Summary of Contents for 19280

Page 1: ...fillment of the technical requirements of the ESD Control Program Plan Process monitoring measurements shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verified the measurement limits and the frequency at which those verifications shall occur The Compliance Verification Plan shall document the test methods and equipment used for ...

Page 2: ...ton Head Screws 1 4 20 x 3 4 1 Allen Wrench 5 32 1 Flat Head Screw 8 32 x 5 8 1 Knurled Nut 8 32 1 Black Cap 1 Poster 1 Certificate of Calibration 19283 COMBO TESTER WITH STAINLESS STEEL FOOT PLATE 1 Combo Tester 1 Foot Plate Cord 5 inches 1 9V Battery 1 Stainless Steel Foot Plate 1 Foot Plate Cord 6 feet 1 Certificate of Calibration Figure 2 Desco 19282 Combo Tester with Stand and Foot Plate Figu...

Page 3: ...l foot plate 19283 98273 D Rocker Switch Toggle to the left when performing a footwear test Toggle to the right when performing a wrist strap test E Single Wire Wrist Strap Jack Insert your single wire wrist cord here to test your wrist strap F Test Switch Push down and hold your finger here to perform a test G Low Battery LED Illuminates when the battery power is low and needs to be replaced 9825...

Page 4: ... plate using the 3 included button head screws and allen wrench Figure 8 Combo Tester keyhole slots 4 Mount the Combo Tester onto the screws and pull it down to secure it into place 5 Set the Stainless Steel Foot Plate below the tester if applicable 6 Insert the 6 long foot plate cord s banana plug into the Combo Tester s foot plate jack Figure 9 Inserting the foot plate cord s banana jack into th...

Page 5: ... and or needs to be replaced NOTE 1 The Combo Tester may briefly display FAIL HIGH once the test button is released at the conclusion of a test Residual voltage in the circuit s capacitors causes the test to continue for a split second after the button is released NOTE 2 Failures may be caused by dry skin or minimal sweat layer For wrist straps try using an approved dissipative hand lotion such as...

Page 6: ... There are no user serviceable parts If your meter requires service beyond cleaning the test switch or foot plate please contact the factory Use a minimum of 80 isopropyl alcohol to clean the test switch Other cleaners are susceptible to leaving residue BATTERY REPLACMENT The low battery indicator flashes briefly every time the unit is used Replace the battery once the indicator becomes constant d...

Page 7: ...Desco Terms and Conditions Specifications COMBO TESTER Power Supply 9V Alkaline Battery or optional AC power adapter Operating Temperature 32 F to 104 F 0 to 40 C Wrist Strap Test Limit 750 kilohms to 10 megohms Footwear Test Limit 750 kilohms to 100 megohms Test Accuracy 20 Test Voltage 4 VDC Dimensions 3 3 x 5 6 x 1 5 Weight 0 5 lbs STAND AND FOOT PLATE Stand Height 36 Foot Plate Dimensions 18 x...

Reviews: