Operation

WRIST STRAP TEST

1.  While wearing a wrist strap, plug the wrist cord 

into the wrist strap jack located on the face of the 

Combo Tester. 

2.  Toggle the rocker switch to the right toward WRIST 

STRAP. 

3.  Push down and hold the test switch until the test 

results are displayed.  Ensure that your finger 

also makes contact with the metal ring around the 

pushbutton when performing a test. 

 

DO NOT touch any other metal while performing 

your test as this will affect your results. 

4.  A “PASS” test result is indicated by illumination 

of the green LED.  A “FAIL LOW” test result is 

indicated by illumination of the red LED.  A “FAIL 

HIGH” test result is indicated by illumination of the 

yellow LED. 

 

If your ESD test fails, check your wrist strap and 

ensure that it is being worn correctly and/or needs 

to be replaced.

NOTE 1: The Combo Tester may briefly display “FAIL 

HIGH” once the test button is released at the conclusion 

of a test.  Residual voltage in the circuit’s capacitors 

causes the test to continue for a split second after the 

button is released. 
NOTE 2: Failures may be caused by dry skin or minimal 

sweat layer.  For wrist straps, try using an approved 

dissipative hand lotion such as 

Menda Reztore™ ESD 

Hand Lotion

 to your wrist prior to use.

FOOTWEAR TEST

1.  Toggle the rocker switch to the left toward FOOT 

PLATE. 

2.  While wearing ESD footwear, place one foot on 

the foot plate, and lift the second foot off the floor.  

Make sure there is no wrist cord plugged into the 

WRIST STRAP jack. 

3.  Push down and hold the test switch until the test 

results are displayed.  Ensure that your finger 

also makes contact with the metal ring around the 

pushbutton when performing a test. 

 

DO NOT touch any other metal while performing 

your test as this will affect your results. 

Figure 12.  Completed Combo Tester with Stand and 

Foot Plate assembly

Figure 13.  Performing a wrist strap test

Figure 14.  Performing a footwear test with the 

19282

 

Combo Tester with Stand and Foot Plate

Summary of Contents for 19280

Page 1: ...fillment of the technical requirements of the ESD Control Program Plan Process monitoring measurements shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verified the measurement limits and the frequency at which those verifications shall occur The Compliance Verification Plan shall document the test methods and equipment used for ...

Page 2: ...ton Head Screws 1 4 20 x 3 4 1 Allen Wrench 5 32 1 Flat Head Screw 8 32 x 5 8 1 Knurled Nut 8 32 1 Black Cap 1 Poster 1 Certificate of Calibration 19283 COMBO TESTER WITH STAINLESS STEEL FOOT PLATE 1 Combo Tester 1 Foot Plate Cord 5 inches 1 9V Battery 1 Stainless Steel Foot Plate 1 Foot Plate Cord 6 feet 1 Certificate of Calibration Figure 2 Desco 19282 Combo Tester with Stand and Foot Plate Figu...

Page 3: ...l foot plate 19283 98273 D Rocker Switch Toggle to the left when performing a footwear test Toggle to the right when performing a wrist strap test E Single Wire Wrist Strap Jack Insert your single wire wrist cord here to test your wrist strap F Test Switch Push down and hold your finger here to perform a test G Low Battery LED Illuminates when the battery power is low and needs to be replaced 9825...

Page 4: ... plate using the 3 included button head screws and allen wrench Figure 8 Combo Tester keyhole slots 4 Mount the Combo Tester onto the screws and pull it down to secure it into place 5 Set the Stainless Steel Foot Plate below the tester if applicable 6 Insert the 6 long foot plate cord s banana plug into the Combo Tester s foot plate jack Figure 9 Inserting the foot plate cord s banana jack into th...

Page 5: ... and or needs to be replaced NOTE 1 The Combo Tester may briefly display FAIL HIGH once the test button is released at the conclusion of a test Residual voltage in the circuit s capacitors causes the test to continue for a split second after the button is released NOTE 2 Failures may be caused by dry skin or minimal sweat layer For wrist straps try using an approved dissipative hand lotion such as...

Page 6: ... There are no user serviceable parts If your meter requires service beyond cleaning the test switch or foot plate please contact the factory Use a minimum of 80 isopropyl alcohol to clean the test switch Other cleaners are susceptible to leaving residue BATTERY REPLACMENT The low battery indicator flashes briefly every time the unit is used Replace the battery once the indicator becomes constant d...

Page 7: ...Desco Terms and Conditions Specifications COMBO TESTER Power Supply 9V Alkaline Battery or optional AC power adapter Operating Temperature 32 F to 104 F 0 to 40 C Wrist Strap Test Limit 750 kilohms to 10 megohms Footwear Test Limit 750 kilohms to 100 megohms Test Accuracy 20 Test Voltage 4 VDC Dimensions 3 3 x 5 6 x 1 5 Weight 0 5 lbs STAND AND FOOT PLATE Stand Height 36 Foot Plate Dimensions 18 x...