Installation

The Combo Tester is portable when powered by a 9V 

alkaline battery, but it also has the flexibility of being 

permanently installed at a location.  Use the three 

keyhole slots located on the back of the Combo Tester 

to mount it to a wall or stand.

INSTALLING THE 

19280

 / 

19283

 COMBO TESTER

1.  Install the 9V alkaline battery into the Combo 

Tester. 

2.  Select a location to mount the Combo Tester. 
3.  Install three #6 or #8 screws into a wall or other 

vertical surface as shown in the figure below.  Make 

sure that the screw heads do not project out more 

than 1/4" from mounting surface. 

INSTALLING THE 

19282

 COMBO TESTER WITH 

STAND AND FOOT PLATE

1.  Position the pedestal on top of the foot plate with 

the mounting bracket sloping toward the operator.  

Secure the pedestal to the foot plate using the 3 

included button head screws and allen wrench. 

Figure 8.  Combo Tester keyhole slots

4.  Mount the Combo Tester onto the screws, and pull 

it down to secure it into place. 

5.  Set the Stainless Steel Foot Plate below the tester 

(if applicable). 

6.  Insert the 6' long foot plate cord’s banana plug into 

the Combo Tester’s foot plate jack. 

Figure 9.  Inserting the foot plate cord’s banana jack into 

the Combo Tester

7.  Snap the opposite end of the foot plate cord onto 

the Stainless Steel Foot Plate.

Figure 10.  Securing the pedestal to the foot plate

2.  Install the 9V alkaline battery into the Combo 

Tester. 

3.  Mount the Combo Tester onto the pedestal’s 

mounting bracket and flat head screw, and screw 

down to secure it into place. 

4.  Insert the 5" long foot plate cord’s banana plug into 

the Combo Tester’s foot plate jack. 

5.  Attach the foot plate cord’s ring terminal to the flat 

head screw located at the back of the pedestal’s 

mounting bracket, and tighten the knurled nut to 

secure. 

Figure 11.  Installing the Combo Tester to the pedestal

6.  Cover the knurled nut and flat head screw with 

included insulative vinyl cap. 

7.  Install the included poster at eye level nearby the 

test station.

Summary of Contents for 19280

Page 1: ...fillment of the technical requirements of the ESD Control Program Plan Process monitoring measurements shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verified the measurement limits and the frequency at which those verifications shall occur The Compliance Verification Plan shall document the test methods and equipment used for ...

Page 2: ...ton Head Screws 1 4 20 x 3 4 1 Allen Wrench 5 32 1 Flat Head Screw 8 32 x 5 8 1 Knurled Nut 8 32 1 Black Cap 1 Poster 1 Certificate of Calibration 19283 COMBO TESTER WITH STAINLESS STEEL FOOT PLATE 1 Combo Tester 1 Foot Plate Cord 5 inches 1 9V Battery 1 Stainless Steel Foot Plate 1 Foot Plate Cord 6 feet 1 Certificate of Calibration Figure 2 Desco 19282 Combo Tester with Stand and Foot Plate Figu...

Page 3: ...l foot plate 19283 98273 D Rocker Switch Toggle to the left when performing a footwear test Toggle to the right when performing a wrist strap test E Single Wire Wrist Strap Jack Insert your single wire wrist cord here to test your wrist strap F Test Switch Push down and hold your finger here to perform a test G Low Battery LED Illuminates when the battery power is low and needs to be replaced 9825...

Page 4: ... plate using the 3 included button head screws and allen wrench Figure 8 Combo Tester keyhole slots 4 Mount the Combo Tester onto the screws and pull it down to secure it into place 5 Set the Stainless Steel Foot Plate below the tester if applicable 6 Insert the 6 long foot plate cord s banana plug into the Combo Tester s foot plate jack Figure 9 Inserting the foot plate cord s banana jack into th...

Page 5: ... and or needs to be replaced NOTE 1 The Combo Tester may briefly display FAIL HIGH once the test button is released at the conclusion of a test Residual voltage in the circuit s capacitors causes the test to continue for a split second after the button is released NOTE 2 Failures may be caused by dry skin or minimal sweat layer For wrist straps try using an approved dissipative hand lotion such as...

Page 6: ... There are no user serviceable parts If your meter requires service beyond cleaning the test switch or foot plate please contact the factory Use a minimum of 80 isopropyl alcohol to clean the test switch Other cleaners are susceptible to leaving residue BATTERY REPLACMENT The low battery indicator flashes briefly every time the unit is used Replace the battery once the indicator becomes constant d...

Page 7: ...Desco Terms and Conditions Specifications COMBO TESTER Power Supply 9V Alkaline Battery or optional AC power adapter Operating Temperature 32 F to 104 F 0 to 40 C Wrist Strap Test Limit 750 kilohms to 10 megohms Footwear Test Limit 750 kilohms to 100 megohms Test Accuracy 20 Test Voltage 4 VDC Dimensions 3 3 x 5 6 x 1 5 Weight 0 5 lbs STAND AND FOOT PLATE Stand Height 36 Foot Plate Dimensions 18 x...

Reviews: