background image

www.desatech.com

901267-01E

5

INSTALLATION

  CAUTION:  Do  not  remove 

the data plates attached to the 

burner  pan.  The  data  plates 

contain  important  warranty  in

-

formation.

 WARNING: Before installing 

in a solid fuel burning fireplace, 

the  chimney  flue  and  firebox 

must be cleaned of soot, creo

-

sote, ashes and loose paint by 

a  qualified  chimney  cleaner. 

Creosote  will  ignite  if  highly 

heated. A dirty chimney flue may 

create and distribute soot within 

the house. Inspect chimney flue 

and firebox for damage. If dam

-

aged, repair flue before operat

-

ing heater.

NOTICE:  Installation,  service 

and repair of this appliance must 

be performed by a qualified in

-

staller, service agency, company 

or gas supplier experienced with 

this type of gas appliance. Only 

factory authorized components 

listed in these instructions may 

be used in accordance with the 

manufacturer’s  instructions 

and all codes and requirements 

of  the  authority  having  juris

-

diction.  Any  modifications  to 

this kit or use of unauthorized 

components or accessory items 

will  void  the  manufacturer’s 

warranty  and  may  result  in  a 

hazardous condition.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed 
only  in  a  solid-fuel  burning  fireplace  with  a 
working flue and constructed of noncombus-
tible material.

The  charts  in  Figure  2  indicate  technical 
information regarding the installation of your 
gas log set. Please make sure that all of the 
specifications  shown  are  applicable  before 
installation is attempted.
The fireplace must include a working flue and 
venting system with the minimum openings 
shown in the Figure 2.

MODEL

Btu/Hr 

Input 

Natural 

Gas

Btu/Hr 

Input 

Propane/

LP Gas

Minimum 

Vent 

Opening

VVMR18

FVMR18

18" Multi-Side

55,000

45,000

8" dia.

VVMR24

FVMR24

24" Multi-Side

65,000

55,000

8" dia.

MINIMUM FIREBOX SIZES

LOG 
SIZE

FRONT 

WIDTH*

BACk 

WIDTH**

DEPTH

HEIGHT

18"

28"

28"

16"

18"

24"

29 

3

/

4

"

29 

3

/

4

"

16"

18"

**At depth indicated

FUEL INLET PRESSURE

SPECIFICATIONS (W.C.)

Min.

Max.

NG

5.5"

10.5"

LP

11"

13"

Figure 2 - Technical Information Charts

BURNER ORIFICE

Log 

Size

Natural

Propane/LP

In.

Num.

In.

Num.

18"

0.111

34

0.073

49

24"

0.129

30

0.086

 44

f i r e - p a r t s . c o m

Summary of Contents for VMLR18

Page 1: ...lammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your...

Page 2: ...ad and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Improper instal lation adjustment alteration service or maintenance...

Page 3: ...wish to add more ventilation by opening a window safety Continued 7 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 13 8 Do not allow fans to blow directly int...

Page 4: ...______ Serial Number _ ______________________ Log Set Model ______________________ ON OFF Safety Valve Pilot kit and Propane lp conversion An optional valve safety pilot kit with a piezo ignitor is av...

Page 5: ...use of unauthorized componentsoraccessoryitems will void the manufacturer s warranty and may result in a hazardous condition FLUE OPENING SPECIFICATIONS Note This vented appliance must be installed o...

Page 6: ...n Continued Figure 3 Attaching Damper Clamp CONNECTING TO GAS SUPPLY WARNING A qualified ser vice person must connect log set to gas supply Follow all local codes Installation Items Needed Before inst...

Page 7: ...ce with its appliance main gas valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pip...

Page 8: ...Figure 7 Adjust to most convenient position 4 Install gas connector tube to gas supply fitting Carefully shape tube to attach to adapter fitting Be careful not to cause kinks in tube 5 Using 1 4 x 8...

Page 9: ...pipe Adjust to most convenient position 6 Install gas connector tube to gas supply fitting Carefully shape tube to attach to adapter fitting Be careful not to cause kinks in tube 7 Test for leaks fol...

Page 10: ...pane LP burner inlet fitting Choose the correct orifice for your log set size and install in place of orifice you just removed 4 Using thread sealant resistant to action of propane LP gas on larger en...

Page 11: ...aming ports with a modi fied paper clip or other suitable tool 5 When finished testing turn gas shutoff valve OFF to extinguish all flames Adding Pan Material 1 Open bags of ash bed material vermicu l...

Page 12: ...n material about 2 from end of supply side of pan 5 Slowly turn gas shutoff valve ON until burner ignites If burner does not ignite within 10 seconds with match burning turn shutoff valve OFF and repe...

Page 13: ...r should light If burner does not light call a quali fied service person 9 To shut off burner only leaving pilot lit turn control knob clockwise to the POLOT position OPERATIon Continued Pilot Thermoc...

Page 14: ...arbon soot where flames contact the logs This is especially true with pro pane LP gas Burner is excessively noisy Note The movement and combustion of gas will cre ate low unavoidable levels of noise B...

Page 15: ...d tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Reconnect leads 1 Adjust pilot...

Page 16: ...ntracting while cooling 1 Log Set burning vapors from paint hair spray glues cleaners chemi cals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1 Gas leak...

Page 17: ...ve ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty C...

Page 18: ...www desatech com 901267 01E 18 Parts Burner Models VVMR18 VVMR24 FVMR18 and FVMR24 3 1 8 6 12 10 11 10 4 2 7 9 5 fire parts com...

Page 19: ...r 1 901064 03 Natural Gas Injector 1 5 901763 02 Burner Manifold 1 901763 01 Burner Manifold 1 6 901767 02 Burner Pan 1 901767 01 Burner Pan 1 7 901242 01 Damper Clamp Std Assembly 1 8 901232 01 Gas L...

Page 20: ...s on page 17 of this manual 1 5 6 3 4 7 2 Kingston Split Oak Logs KEY NO PART NO DESCRIPTION QTY 1 901123 01 Bottom Log VCB 13 2 901123 02 Bottom Log VCB 14 2 2 901122 01 Bottom Log VCB 11 2 901122 02...

Page 21: ...arts on page 17 of this manual 3 1 6 7 5 4 2 Manchester Split Oak Logs KEY NO PART NO DESCRIPTION QTY 1 901472 01 Bottom Log FC 8 2 901472 02 Bottom Log FC 10 2 2 901473 01 Bottom Log FC 9 2 901473 02...

Page 22: ...models For decorative purposes only Not to be used as additional logs on unit Individual Split Log GA9550A For decorative purposes only Not to be used as additional logs on unit Purchase these access...

Page 23: ..._________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 24: ...DESA Heating LLC Authorized Service Center or a provider approved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will prov...

Reviews: