background image

901267-01

Rev. E
08/08

901267 01

NOT A UPC

DESA Heating, LLC
2701 Industrial Drive
Bowling Green, KY 42101
www.desatech.com

1-866-672-6040

WARRANTy

kEEP ThIS WARRANTy

DESA hEATING, LLC LIMITED WARRANTIES

New Products

Standard Warranty:

 DESA Heating, LLC warrants this new product and any parts thereof to be free from 

defects in material and workmanship for a period of two (2) years from the date of first purchase from an 
authorized dealer provided the product has been installed, maintained and operated in accordance with 
DESA Heating, LLC’s warnings and instructions. When installed in a listed outdoor solid fuel burning fire

-

place, the warranty is limited to one (1) year for the burner system and logs.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from 
the date of first purchase.

Factory Reconditioned Products

Limited Warranty:

 DESA Heating, LLC warrants factory reconditioned products and any parts thereof 

to be free from defects in material and workmanship for 30 days from the date of first purchase from an 
authorized dealer provided the product has been installed, maintained and operated in accordance with 
DESA Heating, LLC’s warnings and instructions.

Terms Common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under 
this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, 
and only when installed by a qualified installer in accordance with all local codes and instructions furnished 
with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and 
an allowance for labor when provided by a DESA Heating, LLC Authorized Service Center or a provider 
approved by DESA Heating, LLC. Warranty parts must be obtained through authorized dealers of this prod

-

uct and/or DESA Heating, LLC who will provide original factory replacement parts. Failure to use original 
factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty 
repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the 
responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, 
improper installation, lack of proper maintenance, tampering, or alteration(s).
This is DESA Heating, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty 
excludes any and all other warranties, express or implied, written or verbal and limits the duration of any 
and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two 
(2) years on new products and 30 days on factory reconditioned products from the date of first purchase. 
DESA Heating, LLC makes no other warranties regarding this product.
DESA Heating, LLC’s liability is limited to the purchase price of the product, and DESA Heating, LLC shall 
not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or 
consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 
For information about this warranty contact:

Model (

located on product or identification tag)

 _____________________________

Serial No. (located on product or identification tag)

 __________________________

Date Purchased 

 __________________________

Keep receipt for warranty verification.

f i r e - p a r t s . c o m

Summary of Contents for VMLR18

Page 1: ...lammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your...

Page 2: ...ad and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Improper instal lation adjustment alteration service or maintenance...

Page 3: ...wish to add more ventilation by opening a window safety Continued 7 To reduce the creation of soot follow the instructions in Cleaning and Maintenance page 13 8 Do not allow fans to blow directly int...

Page 4: ...______ Serial Number _ ______________________ Log Set Model ______________________ ON OFF Safety Valve Pilot kit and Propane lp conversion An optional valve safety pilot kit with a piezo ignitor is av...

Page 5: ...use of unauthorized componentsoraccessoryitems will void the manufacturer s warranty and may result in a hazardous condition FLUE OPENING SPECIFICATIONS Note This vented appliance must be installed o...

Page 6: ...n Continued Figure 3 Attaching Damper Clamp CONNECTING TO GAS SUPPLY WARNING A qualified ser vice person must connect log set to gas supply Follow all local codes Installation Items Needed Before inst...

Page 7: ...ce with its appliance main gas valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pip...

Page 8: ...Figure 7 Adjust to most convenient position 4 Install gas connector tube to gas supply fitting Carefully shape tube to attach to adapter fitting Be careful not to cause kinks in tube 5 Using 1 4 x 8...

Page 9: ...pipe Adjust to most convenient position 6 Install gas connector tube to gas supply fitting Carefully shape tube to attach to adapter fitting Be careful not to cause kinks in tube 7 Test for leaks fol...

Page 10: ...pane LP burner inlet fitting Choose the correct orifice for your log set size and install in place of orifice you just removed 4 Using thread sealant resistant to action of propane LP gas on larger en...

Page 11: ...aming ports with a modi fied paper clip or other suitable tool 5 When finished testing turn gas shutoff valve OFF to extinguish all flames Adding Pan Material 1 Open bags of ash bed material vermicu l...

Page 12: ...n material about 2 from end of supply side of pan 5 Slowly turn gas shutoff valve ON until burner ignites If burner does not ignite within 10 seconds with match burning turn shutoff valve OFF and repe...

Page 13: ...r should light If burner does not light call a quali fied service person 9 To shut off burner only leaving pilot lit turn control knob clockwise to the POLOT position OPERATIon Continued Pilot Thermoc...

Page 14: ...arbon soot where flames contact the logs This is especially true with pro pane LP gas Burner is excessively noisy Note The movement and combustion of gas will cre ate low unavoidable levels of noise B...

Page 15: ...d tighten until snug then tighten 1 4 turn more 6 Replace thermocouple 7 Replace control valve 1 Clean burner orifice 2 Contact local natural or propane LP gas company 3 Reconnect leads 1 Adjust pilot...

Page 16: ...ntracting while cooling 1 Log Set burning vapors from paint hair spray glues cleaners chemi cals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1 Gas leak...

Page 17: ...ve ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty C...

Page 18: ...www desatech com 901267 01E 18 Parts Burner Models VVMR18 VVMR24 FVMR18 and FVMR24 3 1 8 6 12 10 11 10 4 2 7 9 5 fire parts com...

Page 19: ...r 1 901064 03 Natural Gas Injector 1 5 901763 02 Burner Manifold 1 901763 01 Burner Manifold 1 6 901767 02 Burner Pan 1 901767 01 Burner Pan 1 7 901242 01 Damper Clamp Std Assembly 1 8 901232 01 Gas L...

Page 20: ...s on page 17 of this manual 1 5 6 3 4 7 2 Kingston Split Oak Logs KEY NO PART NO DESCRIPTION QTY 1 901123 01 Bottom Log VCB 13 2 901123 02 Bottom Log VCB 14 2 2 901122 01 Bottom Log VCB 11 2 901122 02...

Page 21: ...arts on page 17 of this manual 3 1 6 7 5 4 2 Manchester Split Oak Logs KEY NO PART NO DESCRIPTION QTY 1 901472 01 Bottom Log FC 8 2 901472 02 Bottom Log FC 10 2 2 901473 01 Bottom Log FC 9 2 901473 02...

Page 22: ...models For decorative purposes only Not to be used as additional logs on unit Individual Split Log GA9550A For decorative purposes only Not to be used as additional logs on unit Purchase these access...

Page 23: ..._________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 24: ...DESA Heating LLC Authorized Service Center or a provider approved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will prov...

Reviews: