www.fmiproducts.com
111826-04E
19
OPERATION
Continued
MANUAL OPERATION
Lighting with Piezo Ignitor
1. Disconnect ignitor cable from receiver and
connect to Piezo Ignitor Tab (see Figure
18 and
Wiring Diagram
on page 27).
2. STOP! Read safety information on page 16.
3. Make sure equipment shutoff valve is fully
open.
4. Turn motor knob clockwise
to the
OFF position.
5. Wait (5) minutes to clear any gas and
then smell for gas around heater and
near floor. If you smell gas, STOP! follow
"B" on page 16.
6. ON/OFF switch in "—" ON position.
7. MAN-knob on valve is in MAN position
(see Figure 18), When in MAN position
you can see a metallic core.
8. Push and hold down metal core fully with
a pen while the pilot gas flows.
9. Press and release piezo ignitor button until
pilot lights.
10. Continue holding down metal core for
about 10 seconds and then release the
metal core. Pilot should stay lit. If not,
repeat steps one through 4.
11. Turn MAN knob to ON position - main gas
flows.
12. Turn Motor-knob to adjust flame. Knob
has a slipping clutch that allows manual
flame height adjustment.
Figure 18 - PJD Control Valve
Piezo
Ignitor
Tab
Metalic
Core for
Manual
Ignition
Piezo Ignitor
ON/OFF Switch
Microswitch
MAN Knob
in Manual
Position
Motor
Knob
in ON
Position
Figure 19 - Pilot
TO TURN GAS OFF
TO APPLIANCE
Shutting Off Heater
Press OFF button on remote control to switch
off main gas and pilot gas or manually turn
Motor-Knob clockwise
to the "O" OFF
position.
Shutting Off Burner Only (pilot stays lit)
Press to decrease the flame height and shut
off main burner.