The hearth extension must be made of non-combustible, 
inorganic material having an effective thermal conductivity 
“K” of 0.84 BTU IN/FT.HR.F (or less) at 1 inch thick. 
 
Thermal conductivity “K” of materials can be obtained from 
the manufacturer of the non-combustible material.  The 
minimum required thickness for any material could be 
obtained by the following formula: 
 

K factor at 1 inch  = thickness required 

                              0.84 
For example, if the material selected has a K factor of 0.25, 
such as a glass fiber, the following formula would apply: 
 

0.25 = 0.30 thickness required 

                          0.84 
If the hearth extension is to be covered, use non-combustible 
material such as tile, slate, brick, concrete, metal, glass, 
marble, stone etc.  Provide a means to prevent the hearth 
extension from shifting and seal the gap between the fireplace 
frame and hearth extension with a non-combustible material 
(see figure 4). 

 

OPTIONAL OUTSIDE AIR KIT (MODELS AK4 OR 
AK4F): 
 

The outside air kit must be installed during the rough framing 
of the fireplace due to the nature of its location.  Outside 
combustion air can be accessed through an exterior wall 
(Model AK4) or a vented crawl space (Model AK4F).  See 
figure 5 and Accessories on page 11. 
 
Avoid installing outside air eyebrow in areas where inlet 
opening may be blocked by snow, bushes or other obstacles.  
It should also be located beyond the reach of children.  The 
maximum height of air inlet above platform of fireplace is 3 ft. 
below the termination flue gas outlet. 
 
 

 

 
For further details on the installation of the outside air kit, 
please refer to the instructions included with the air kit.  For 
operating instructions please refer to your owner’s manual. 
 
The outside air handle is located at the left-hand side of the 
fireplace refractory (see figure 6, Model V(I)36NCR shown).  
To close, pull down; to open, push up.  Always open the 
mechanism when starting a fire to provide adequate outside 
combustion air.  Close the mechanism when not in use to 
prevent cold air from entering the room.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
GAS LINE INSTALLATION (OPTIONAL): 

 
Gas line hook up should be done by your supplier or a 
qualified service person. 

NOTE:

 Before you proceed, make sure your gas supply is 

turned off. 
 

 WARNING:

 HEARTH EXTENSION IS TO BE 

INSTALLED ONLY AS DESCRIBED. 

 

Figure 5           AIR KIT INSTALLATION 

 CAUTION:

AIR DUCTS MUST NOT TERMINATE 

IN ATTIC SPACE OR GARAGE. 

 

Figure 4          HEARTH EXTENSIONS 

Figure 6              AIR KIT DAMPER ROD 

f i r e - p a r t s . c o m

Summary of Contents for VANGUARD V36NCL

Page 1: ...ted VI36NCL Left Side Opening Fully Insulated INSTALLATION INSTRUCTIONS This Fireplace is approved for use as a Wood Burning Fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 or...

Page 2: ...HE FIREPLACE PG 3 8 HEARTH EXTENSION PG 3 9 OUTSIDE AIR KIT PG 4 10 GAS LINE INSTALLATION PG 4 11 VENT FREE GAS LOG INSTALLATION PG 5 12 COLD CLIMATE INSTALLATIONS PG 5 13 CHIMNEY PIPE PG 6 7 14 PENET...

Page 3: ...ON is the most important step in ensuring safe and continuous operation of this fireplace SELECTING LOCATION To determine the safest and most efficient location for your fireplace consider the followi...

Page 4: ...n hearth extensions not supplied and under the bottom front edge of the fireplace to protect against glowing embers falling through If the fireplace is to be installed on a raised platform a Z type em...

Page 5: ...ssed through an exterior wall Model AK4 or a vented crawl space Model AK4F See figure 5 and Accessories on page 11 Avoid installing outside air eyebrow in areas where inlet opening may be blocked by s...

Page 6: ...talled when using an unvented gas log set see accessories on page 11 VENTED GAS LOG INSTALLATION If you install a decorative gas appliance vented gas log the decorative gas appliance must comply with...

Page 7: ...ipe segments planned for maximum adaptability to individual site requirements Actual lengths gained lineal gain after fitting overlaps must be taken into consideration see figure 11 Each double wall c...

Page 8: ...c space as required by most codes When the double wall pipe passes through a framed opening into an attic space the firestop must be place into the attic floor as in figure 15 When the pipe passes thr...

Page 9: ...he correct opening length and flashing required STEP 4 Remove the shingles around the opening measured and cut out this section STEP 5 Add the next sections of the pipe until the end penetrates the ro...

Page 10: ...r chase and ETL 8DM for chase style termination only Figure 21 shows an RTL 8DM round top termination FOLLOW THE INSTALLATION INSTRUCTIONS PROVIDED WITH THE TERMINATION BEING USED CHASE INSTALLATIONS...

Page 11: ...t 9 inches above the opening of the fireplace see figure 24 Combustible materials above 9 inches and projecting more than 1 inches from the front face of the fireplace must be place at least 12 inches...

Page 12: ...www desatech com Desa International 2701 Industrial Drive P O Box 90024 Bowling Green KY 42102 9004 www desatech com 800 323 5190 ACCESSORY PARTS REPLACEMENT PARTS CONTACT YOUR LOCAL DEALER CONTACT YO...

Reviews: