MINIMUM CLEARANCES TO COMBUSTIBLES: 

 

 

Back and sides of fireplace …………………….. ¾” min. 

 

Top spacers ……………………………………..  0” min. 

 

Perpendicular side wall to opening of unit ……. 18” min. 

 

Bottom of fireplace to floor 
(see step 2 under installing a fireplace) ………....  0” min. 

 

Mantel clearances …………………………   see page 10 

 

Chimney outer pipe surfaces ………………….     2” min. 

 

Chase inside dimension ……………………  16-1/2” min. 

 
 

 
 

INSTALLING THE FIREPLACE: 

 
STEP 1: Frame the opening for the fireplace using the 
dimensions shown in figures 1 & 2. 
 
STEP 2: If the fireplace is to be installed directly on carpeting, 
tile (other than ceramic), or any combustible material other 
than wood flooring; the fireplace must be installed upon a 
metal or wood panel extending the full width and depth of the 
fireplace. 
  
STEP 3: Set the fireplace directly in front of this opening and 
slide the unit back until the nailing flanges touch the side 
framing. 
 
STEP 4: Check the level of the fireplace and shim with sheet 
metal if necessary. 
 
STEP 5: Before securing fireplace to prepared framing, the 
ember protector (provided), must be placed between hearth 
extensions (not supplied), and under the bottom front edge of 
the fireplace to protect against glowing embers falling 
through.  If the fireplace is to be installed on a raised platform, 
a Z-type ember protector (not supplied) must be fabricated to 
fit your required platform height.  The ember protector should 
extend under the fireplace a minimum of 1”.  The ember 
protector should be made of galvanized sheet metal (28 Ga. 
minimum) to prevent corrosion (see figure 4). 
 
STEP 6: Secure the fireplace to the framing through flanges 
located on the sides of the fireplace (see figure 3). 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

HEARTH EXTENSION: 

 
A hearth extension is required to protect the combustible floor 
constructed in front of the fireplace.  The hearth extension is 
not included and must be fabricated.  The hearth extension 
must project at least 12 inches one side and 20 inches on the 
other side of the fireplace opening (see drawing on front 
cover). 
 

 WARNING:

 Do not pack air spaces with insulation or 

any other material.  Do not obstruct fireplace openings (ie. 
louvers, etc.) with any type of facing material. 
Combustible material must not be in contact with the back 
front face of the fireplace. 

Figure 1  

FRAMING DIMENSIONS 

Figure 2                CORNER INSTALLATION 

Figure 3  

NAILING FLANGES 

f i r e - p a r t s . c o m

Summary of Contents for VANGUARD V36NCL

Page 1: ...ted VI36NCL Left Side Opening Fully Insulated INSTALLATION INSTRUCTIONS This Fireplace is approved for use as a Wood Burning Fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 or...

Page 2: ...HE FIREPLACE PG 3 8 HEARTH EXTENSION PG 3 9 OUTSIDE AIR KIT PG 4 10 GAS LINE INSTALLATION PG 4 11 VENT FREE GAS LOG INSTALLATION PG 5 12 COLD CLIMATE INSTALLATIONS PG 5 13 CHIMNEY PIPE PG 6 7 14 PENET...

Page 3: ...ON is the most important step in ensuring safe and continuous operation of this fireplace SELECTING LOCATION To determine the safest and most efficient location for your fireplace consider the followi...

Page 4: ...n hearth extensions not supplied and under the bottom front edge of the fireplace to protect against glowing embers falling through If the fireplace is to be installed on a raised platform a Z type em...

Page 5: ...ssed through an exterior wall Model AK4 or a vented crawl space Model AK4F See figure 5 and Accessories on page 11 Avoid installing outside air eyebrow in areas where inlet opening may be blocked by s...

Page 6: ...talled when using an unvented gas log set see accessories on page 11 VENTED GAS LOG INSTALLATION If you install a decorative gas appliance vented gas log the decorative gas appliance must comply with...

Page 7: ...ipe segments planned for maximum adaptability to individual site requirements Actual lengths gained lineal gain after fitting overlaps must be taken into consideration see figure 11 Each double wall c...

Page 8: ...c space as required by most codes When the double wall pipe passes through a framed opening into an attic space the firestop must be place into the attic floor as in figure 15 When the pipe passes thr...

Page 9: ...he correct opening length and flashing required STEP 4 Remove the shingles around the opening measured and cut out this section STEP 5 Add the next sections of the pipe until the end penetrates the ro...

Page 10: ...r chase and ETL 8DM for chase style termination only Figure 21 shows an RTL 8DM round top termination FOLLOW THE INSTALLATION INSTRUCTIONS PROVIDED WITH THE TERMINATION BEING USED CHASE INSTALLATIONS...

Page 11: ...t 9 inches above the opening of the fireplace see figure 24 Combustible materials above 9 inches and projecting more than 1 inches from the front face of the fireplace must be place at least 12 inches...

Page 12: ...www desatech com Desa International 2701 Industrial Drive P O Box 90024 Bowling Green KY 42102 9004 www desatech com 800 323 5190 ACCESSORY PARTS REPLACEMENT PARTS CONTACT YOUR LOCAL DEALER CONTACT YO...

Reviews: