www.desatech.com
112108-01C
3
Modles (V)DVF36TCRE, (V)DVF36TCRPE,
(V)DVF36TCLE and (V)DVF36TCLPE use a
direct spark ignition with a 24 VAC control mod-
ule. All models have HI/LO valve that controls
the flame height.
Fan Kit models DVFFBK and DVFFBKT are
available for these units as an option. If you are
uncertain as to what gas your unit is equipped for,
please check the rating plate located in the interior
of the appliance opening or consult your local
distributor of DESA products.
Carbon Monoxide Poisoning:
Early signs of
carbon monoxide poisoning resemble the flu, with
headaches, dizziness or nausea. If you have these
signs, the fireplace may not be working properly.
Get fresh air at once!
Have fireplace serviced.
Some people are more affected by carbon monoxide
than others. These include pregnant women, people
with heart or lung disease or anemia, those under the
influence of alcohol and those at high altitudes.
Natural and Propane/LP Gas:
Natural and propane/
LP gas are odorless. An odor-making agent is added
to the gas. The odor helps you detect a gas leak.
However, the odor added to the gas can fade. Gas
may be present even though no odor exists.
Make certain you read and understand all warnings.
Keep this manual for reference. It is your guide to
safe and proper operation of this fireplace.
WARNING: Any change to
this fireplace or it’s controls can
be dangerous. Do not modify
this fireplace under any circum
-
stances. Any parts removed for
servicing must be replaced prior
to operating fireplace.
WARNING: Do not use a blow
-
er insert, heat exchanger insert or
other accessory not approved for
use with this fireplace.
WARNING: This appliance
is only for use with the type of
gas indicated on the rating plate.
This appliance is not convertible
for use with other gases unless
a certified kit is used.
DANGER: Carbon monoxide
poisoning may lead to death!
Before beginning the installation of the fireplace,
read these instructions through completely.
• This DESA fireplace and its components are
safe when installed according to this installation
manual. Unless you use DESA components,
which have been designed and tested for the
fireplace system, you may cause a fire hazard.
• The DESA warranty will be voided by and
DESA disclaims any responsibility for the fol-
lowing actions:
a) Modification of the fireplace, components,
doors, air inlet system and damper control.
b) Use of any component part not manufactured
or approved by DESA in combination with
a DESA fireplace system.
c) Installation and/or operation in a manner
other than instructed in this manual.
d) Burning of anything other than the type of
gas approved for use in this gas appliance.
This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the
National Electri-
cal Code, ANSI/NFPA 70
or
CSA C22.1 Canadian
Electrical Code for Canada
.
The installation must conform to local codes,
or in the absence of local codes, with the
Na-
tional Fuel Gas Code ANSI Z223.1
(
CAN B149
.
in CANADA)
This appliance complies with ANSI Z21.50, and
CSA 2.22-2000 as a VENTED GAS FIREPLACE
and is listed and tested by the Canadian Standards
Association.
Proper installation is the most important step in
ensuring safe and continuous operation of the
fireplace. Consult the local building codes as to
the particular requirements concerned with the
installation of all factory built fireplaces.
This fireplace must be installed by a qualified (cer-
tified or licensed) service person. It has a sealed
gas combustion chamber that uses a millivolt gas
control valve with a millivolt ignition system.
Models (V)DVF36TCR, (V)DVF36TCRP,
(V)DVF36TCL and (V)DVF36TCLP are direct-
vent fireplaces with sealed combustion chambers
that use a millivolt gas control valve with a mil-
livolt ignition system.
SAFETy INFORMATION
Continued