background image

2

598-1275-00

INSTALLATION

For easy installation, select an existing light operated 
by a wall switch for replacement.

For best performance, mount the fi xture about 8 ft. (2.4 m) 
above the ground.

CAUTION: Keep the sensor at least 1" (2.5 cm) 
away from the lamps.

  Place the Mounting Bolt through the front of the 

junction box cover. Push the small gasket hole over 
the Mounting Screw.

  Make sure the wire connectors and wires are inside 

the junction box. Align the Mounting Screw with the 
center hole in the Mounting Strap. Secure the fi xture 
to the Mounting Strap.

M

OUNT

 

THE

 L

IGHT

 C

ONTROL

  Push the Rubber Plug fi rmly into place.

  If not installed on a weatherproof box, 

caulk the 

wall plate and mounting surface

 with silicone 

❒ 

Adjust the lamp holders by loosening the lock nuts 
but do not rotate the lamp holders more than 180° 
from the factory setting.

Keep lamps at least 1" (2.5 
cm) from the sensor. 

Black

 to 

Black

White

 to 

White

Gasket

Connect any fi xture ground wire(s) and the cover plate 
ground screw to the junction box ground wire.

CAUTION: To Avoid Fire Or Burn Hazards:

• Allow fi xture to cool before touching. The bulb and the 

fi xture operate at high temperatures.

•  Keep fi xture at least 2" (5 cm) from combustible materi-

als. Do not aim at objects closer than 3 feet. (1 m).

• Use only T3, 150W (max.) tungsten halogen 120 

VAC lamps.

W

IRE

 

THE

 L

IGHT

 C

ONTROL

 WARNING: Turn power off at circuit breaker.

❒ 

Remove the existing light fi xture.

❒ 

Install mounting strap to junction box using screws 
appropriate for your junction box.

  The plastic hanger can be used to hold the fi xture 

while wiring. The small end of the plastic hanger 
can be threaded through the hole in the center of 
the cover plate. The small end then goes into one 
of the slots on the mounting strap.

  Thread all fi xture wires through the large holes in 

the gasket as shown.

  Connect the junction box wires to the light fi xture 

wires as shown. Twist together and secure with 
wire connectors.

Rubber Plug

Mounting 

Bolt

For eave mount only:

  Swing the sensor head towards the clamp screw 

joint.

If the sensor pops out of the ball joint, loosen the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.

  Then rotate the sensor head clockwise 180° so 

the controls face down.

Controls

For under eave installation, the sensor head must 
be rotated

 as shown in the next two steps for proper 

operation and to avoid the risk of electrical shock. 
Also 

for proper under eave operation,

 remove the 

protective backing from the Light Shield and stick on 
as shown below.

Controls

Controls

Clamp Screw

Light Shield 

Opening

B

ULB

 I

NSTALLATION

NOTE:

 Lamps are included, but you will need to 

install them

NOTE:

 When re-lamping, 

turn power off

 and let the 

fi xture cool.

  Open glass covers. To remove the old bulb push the 

bulb towards the right (with fi xture as shown) until 
the left side of the bulb is clear of the left socket.

  To install a bulb, push the bulb into the right socket 

so the bulb fi ts completely into the left socket.

  Check that the bulb is seated properly.

  Close the glass covers.

Push the Rubber Plug 
over the mounting screw.

Summary of Contents for Twin Halogen Motion Sensing Light with 2-Level Lighting 5512

Page 1: ...ighting switch OFF MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then 2 LEVEL LIGHTING TIMER Light comes on half bright for selected time after dusk Off 3 hr 6 hr until dawn If motion is sensed the light turns on full bright for the ON TIME 1 5 or 20 minutes then returns to dim mode Move ON TIME Switch to 1 5 or 20 minutes Mode Switching Summary Flip light switch off for one second the...

Page 2: ...box using screws appropriate for your junction box The plastic hanger can be used to hold the fixture while wiring The small end of the plastic hanger can be threaded through the hole in the center of the cover plate The small end then goes into one of the slots on the mounting strap Thread all fixture wires through the large holes in the gasket as shown Connect the junction box wires to the light...

Page 3: ...gger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor Maximum Range 8 ft 2 4 m Maximum Coverage Angle 70 ft 100 ft 21 m 30 5 m Boosted Least Sensitive Most Sensitive Sensor The detector is less sensitive to motion directly towards it 240 B O O S T MAX MIN RANGE ON TIME DUAL BRITE TEST 1 5 2 0 MINUTES OFF 3 6 DU...

Page 4: ...istance at 1 800 858 8501 7 30 AM to 4 30 PM CST M F You may also write to DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Specialty Products If contacting Technical Service please have the following information available Model Number Date of Pur chase and Place of Purchase No Service Parts Available for this Product 90 DAY LIMITED WARRANTY This is a Limite...

Page 5: ... electricidad por un minuto y préndala de nuevo Después del tiempo de calibración el control estará en fase AUTO MATICA TEMPORIZADOR DEL ALUMBRADO DE 2 NIVELES Laluzseprendeconmediabrillantezporeltiempoescogido después del atardecer apagado 3 hr 6 hrs hasta el amanecer Si detecta movimiento la luz se prende con todosuresplandorporeltiempodeduraciónodeON TIME 1 5 ó 20 minutos y luego regresa a medi...

Page 6: ...ornillo sujetador y empuje el detector hacia dentro de la unión esférica Apriete el tornillo sujetador cuando termine Controles Controles Apertura del protector de lámpara Blanco a blanco Negro a negro Empaquetadura lámina de montaje Perno de montaje Conecte los alambres del aparato propuestos para conexio n a tierra a la conexio n a tierra de la caja de enpalme Enchufe de caucho Mantenga las lámp...

Page 7: ...es como ductos de calefacción y acondiciona dores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales domésticos o el tráfico puedan activar el control Los objetos grandes cercanos y de colores re splandecientes que reflejan la luz del día pueden hacer que el detector se apague No apunte otras luces hacia el detector Angulo de Cobertura Máxima Alcance Máximo Gire el co...

Page 8: ...DE INVESTIGACION DE AVERIAS SERVICIO TÉCNICO No enviar los productos Si tiene algún problema por favor siga esta guía Lo sentimos pero no podemos contestar preguntas en español por teléfono Usted puede también escribir a DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y...

Reviews: