background image

3

598-1275-00

SPECIFICATIONS

Range  . . . . . . . . . . . . . .  Up  to  70  ft.  (21  m);  100  ft.

(30.5 m) with Range Boost. 
[varies with surrounding 
temperature]

Sensing Angle . . . . . . . .  Up to 240°
Electrical Load . . . . . . . .  Up to 300 Watt Maximum In-

candescent [Up to 150 Maxi-
mum each lamp holder].

Power Requirements . . .  120 VAC, 60 Hz
Operating Modes . . . . . .  TEST, AUTO, and MANUAL 

MODE

Time Delay  . . . . . . . . . .  1, 5, 20 minutes
Replacement lamp . . . . .  T3, 150W halogen maximum 

120 VAC

2-Level Lighting Timer . .  Off,  3,  6  hours, Dusk-to-

Dawn

DESA Specialty Products reserves the right to dis-
continue products and to change specifi cations at any 
time without incurring any obligation to incorporate new 
features in products previously sold.

Motion

Motion

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

NOTE:

  Sensor has a 1 

1

/

2

 minute warm up period be-

fore it will detect motion. When fi rst turned on 
or when switching modes wait 1 

1

/

2

 minutes. 

Bottom of Sensor

Avoid aiming the sensor at:

•  Objects that change temperature rapidly, such as 

heating vents and air conditioners.

 These heat 

sources could cause false triggering.

•  Areas where 

pets or traffi c

 may trigger the control.

•  

Nearby large, light-colored objects

 refl ecting light 

may trigger the shut-off feature. Do not point other 
lights at the sensor.

Maximum Range

8 ft. 

(2.4 m)

Maximum

Coverage Angle

 

70 ft. 

100 ft. 

 

(21 m)  (30.5 m)

  

Boosted

  Least Sensitive 

Most Sensitive

Sensor

The detector is less sensitive to motion directly towards it.

240°

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME

DUAL BRITE

TEST 1  5  2 0

MINUTES

OFF  3  6   DUSK TO

HOUR   DAWN

  Turn the RANGE control to the mid position, 2-Level 

Lighting to OFF and the ON-TIME control to the 
TEST position.

  Loosen the clamp screw in the 

sensor ball joint and gently 
rotate the sensor.

  Walk through the coverage 

area noting where you are 
when the lights turn on. Move 
the sensor head up, down, or 
sideways to change the cover-
age area. 

Keep the sensor at 

least 1" (2.5 cm) away from 
the lamps.

  Adjust the RANGE as needed. 

RANGE set too high may 
increase false triggering.

 

Secure the sensor head's 
aim by tightening the clamp 
screw.

 Do not overtighten the 

screw.

  Set the amount of TIME you 

want the lights to stay on after 
motion is detected (1, 5, or 20 minutes).

  Set the 2-Level Lighting switch to the amount of 

time after dusk you want the lights on at low level 
(Off, 3, 6 Hrs., Dusk-to-Dawn).

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

Summary of Contents for Twin Halogen Motion Sensing Light with 2-Level Lighting 5512

Page 1: ...ighting switch OFF MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then 2 LEVEL LIGHTING TIMER Light comes on half bright for selected time after dusk Off 3 hr 6 hr until dawn If motion is sensed the light turns on full bright for the ON TIME 1 5 or 20 minutes then returns to dim mode Move ON TIME Switch to 1 5 or 20 minutes Mode Switching Summary Flip light switch off for one second the...

Page 2: ...box using screws appropriate for your junction box The plastic hanger can be used to hold the fixture while wiring The small end of the plastic hanger can be threaded through the hole in the center of the cover plate The small end then goes into one of the slots on the mounting strap Thread all fixture wires through the large holes in the gasket as shown Connect the junction box wires to the light...

Page 3: ...gger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor Maximum Range 8 ft 2 4 m Maximum Coverage Angle 70 ft 100 ft 21 m 30 5 m Boosted Least Sensitive Most Sensitive Sensor The detector is less sensitive to motion directly towards it 240 B O O S T MAX MIN RANGE ON TIME DUAL BRITE TEST 1 5 2 0 MINUTES OFF 3 6 DU...

Page 4: ...istance at 1 800 858 8501 7 30 AM to 4 30 PM CST M F You may also write to DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Specialty Products If contacting Technical Service please have the following information available Model Number Date of Pur chase and Place of Purchase No Service Parts Available for this Product 90 DAY LIMITED WARRANTY This is a Limite...

Page 5: ... electricidad por un minuto y préndala de nuevo Después del tiempo de calibración el control estará en fase AUTO MATICA TEMPORIZADOR DEL ALUMBRADO DE 2 NIVELES Laluzseprendeconmediabrillantezporeltiempoescogido después del atardecer apagado 3 hr 6 hrs hasta el amanecer Si detecta movimiento la luz se prende con todosuresplandorporeltiempodeduraciónodeON TIME 1 5 ó 20 minutos y luego regresa a medi...

Page 6: ...ornillo sujetador y empuje el detector hacia dentro de la unión esférica Apriete el tornillo sujetador cuando termine Controles Controles Apertura del protector de lámpara Blanco a blanco Negro a negro Empaquetadura lámina de montaje Perno de montaje Conecte los alambres del aparato propuestos para conexio n a tierra a la conexio n a tierra de la caja de enpalme Enchufe de caucho Mantenga las lámp...

Page 7: ...es como ductos de calefacción y acondiciona dores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales domésticos o el tráfico puedan activar el control Los objetos grandes cercanos y de colores re splandecientes que reflejan la luz del día pueden hacer que el detector se apague No apunte otras luces hacia el detector Angulo de Cobertura Máxima Alcance Máximo Gire el co...

Page 8: ...DE INVESTIGACION DE AVERIAS SERVICIO TÉCNICO No enviar los productos Si tiene algún problema por favor siga esta guía Lo sentimos pero no podemos contestar preguntas en español por teléfono Usted puede también escribir a DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y...