background image

4

598-1275-00

POSSIBLE CAUSE

1.  A lamp is positioned too close to the 

sensor or pointed at nearby objects 
that cause heat to trigger the sensor. 

(Reposition the lamp away from the 
sensor or nearby objects)

.

2.  Sensor is pointed toward a heat 

source like an air vent, dryer vent, or 
brightly-painted heat-refl ective surface. 

(Reposition sensor)

.

3.  Light Control is in Manual Mode. 

(Switch 

to Auto)

.

1.  Heat or light from the lamps may be 

turning the Light Control on and off. 

(Reposition the lamps away from the 
sensor)

.

2.  Heat being refl ected from other objects 

may be affecting the sensor. 

(Reposi-

tion sensor)

.

3.  Light Control is in the Test mode and 

warming up. 

(Flashing is normal under 

these conditions. Turn Boost off)

.

1.  Sensor is detecting its own lights. 

(Re-

position lamps to keep area below the 
sensor relatively dark)

.

SYMPTOM

Lights stay 
on continu-
ously.

Lights fl ash 
on and off.

Lights fl ash 
once, then 
stay off in 
Manual Mode.

SYMPTOM

Lights will 
not come on.

Lights come 
on in day-
light.

Lights come 
on for no 
apparent 
reason.

Lights turn 
off too late 
in Dusk-to-
Dawn setting.

POSSIBLE CAUSE

1.  Light switch is turned off.
2.  Light is loose or burned out.
3.  Fuse is blown or circuit breaker is 

turned off.

4.  Daylight turn-off is in effect 

(Recheck 

after dark)

.

5.  Incorrect circuit wiring, if this is a new 

installation.

6.  Re-aim the sensor to cover desired 

area.

1.  Light Control may be installed in a 

relatively dark location.

2.  Light Control is in Test. 

(Set control 

switch to an ON-TIME position)

.

1.  Light Control may be sensing small 

animals or automobile traffi c. 

(Re-aim 

sensor)

.

2.  Sensitivity is set too high. 

(Reduce 

sensitivity)

.

3.  2-Level Lighting Timer is on.

1.  Sensor is in a relatively dark location. 

(Relocate sensor, or use 3 hr or 6 hr 
setting)

.

TROUBLESHOOTING GUIDE

TECHNICAL SERVICE

(Do Not Send Products)

If you experience a problem, follow this guide. You may also want to visit our Web site at: 

www.desatech.com.

 If the 

problem persists, call* for assistance at 

1-800-858-8501,

 7:30 AM to 4:30 PM CST (M-F). You may also write* to:

DESA Specialty Products
P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service Specialty Products
* If contacting Technical Service, please have the following information available: Model Number, Date of Pur-
chase, and Place of Purchase.

No Service Parts Available for this Product

90 DAY LIMITED WARRANTY

This is a “Limited Warranty” which gives you specifi c legal rights. You may also have other rights which vary from state to state or province 
to province.
For a period of 90 days from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected 
at no charge to you.

Not Covered -

 Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expend-

able items are not covered by this warranty. Unauthorized service or modifi cation of the product or of any furnished component will 
void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, 
unauthorized service, or return shipping charges.
This warranty covers only DESA Specialty Products assembled products and is not extended to other equipment and components that 
a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, 
REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PUR-
POSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON 
THE PART OF DESA SPECIALTY PRODUCTS FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, 
INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states 
or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may 
not apply to you. Proof of purchase is required for warranty claims.

Summary of Contents for Twin Halogen Motion Sensing Light with 2-Level Lighting 5512

Page 1: ...ighting switch OFF MANUAL MODE ON TIME TEST 1 5 20 back on AUTO 1 Second OFF then 2 LEVEL LIGHTING TIMER Light comes on half bright for selected time after dusk Off 3 hr 6 hr until dawn If motion is sensed the light turns on full bright for the ON TIME 1 5 or 20 minutes then returns to dim mode Move ON TIME Switch to 1 5 or 20 minutes Mode Switching Summary Flip light switch off for one second the...

Page 2: ...box using screws appropriate for your junction box The plastic hanger can be used to hold the fixture while wiring The small end of the plastic hanger can be threaded through the hole in the center of the cover plate The small end then goes into one of the slots on the mounting strap Thread all fixture wires through the large holes in the gasket as shown Connect the junction box wires to the light...

Page 3: ...gger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor Maximum Range 8 ft 2 4 m Maximum Coverage Angle 70 ft 100 ft 21 m 30 5 m Boosted Least Sensitive Most Sensitive Sensor The detector is less sensitive to motion directly towards it 240 B O O S T MAX MIN RANGE ON TIME DUAL BRITE TEST 1 5 2 0 MINUTES OFF 3 6 DU...

Page 4: ...istance at 1 800 858 8501 7 30 AM to 4 30 PM CST M F You may also write to DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Specialty Products If contacting Technical Service please have the following information available Model Number Date of Pur chase and Place of Purchase No Service Parts Available for this Product 90 DAY LIMITED WARRANTY This is a Limite...

Page 5: ... electricidad por un minuto y préndala de nuevo Después del tiempo de calibración el control estará en fase AUTO MATICA TEMPORIZADOR DEL ALUMBRADO DE 2 NIVELES Laluzseprendeconmediabrillantezporeltiempoescogido después del atardecer apagado 3 hr 6 hrs hasta el amanecer Si detecta movimiento la luz se prende con todosuresplandorporeltiempodeduraciónodeON TIME 1 5 ó 20 minutos y luego regresa a medi...

Page 6: ...ornillo sujetador y empuje el detector hacia dentro de la unión esférica Apriete el tornillo sujetador cuando termine Controles Controles Apertura del protector de lámpara Blanco a blanco Negro a negro Empaquetadura lámina de montaje Perno de montaje Conecte los alambres del aparato propuestos para conexio n a tierra a la conexio n a tierra de la caja de enpalme Enchufe de caucho Mantenga las lámp...

Page 7: ...es como ductos de calefacción y acondiciona dores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales domésticos o el tráfico puedan activar el control Los objetos grandes cercanos y de colores re splandecientes que reflejan la luz del día pueden hacer que el detector se apague No apunte otras luces hacia el detector Angulo de Cobertura Máxima Alcance Máximo Gire el co...

Page 8: ...DE INVESTIGACION DE AVERIAS SERVICIO TÉCNICO No enviar los productos Si tiene algún problema por favor siga esta guía Lo sentimos pero no podemos contestar preguntas en español por teléfono Usted puede también escribir a DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 Si se llama al Servicio Técnico por favor tener lista la siguiente información Número de Modelo Fecha de compra y...