background image

    

  

 
 
 
The 

BANDIT 320

 security fogging system is specifically designed to provide high reliability 

and simple, quick and minimal maintenance requirements.  Each 

BANDIT 320

 system 

consists of a Fog Generator and an associated System Controller which is shown below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Routine service consists of the procedures listed below. 
 

The BANDIT 320 Recommended service schedule

  

 

 

1. 

Annually (Not necessary, but recommended if opportunity arises)

 

(estimated time required 15 

– 20 minutes)

 

 

  Check that the green light is showing on the front of the Fog Generator, which 

indicates the unit is operational. 

 

  Ensure there are no obstructions that may impede the fog output if the Fog 

Generator was to activate. 

 

2. 

Every 2 Years (Required)

 

(estimated time required 25 

– 30 minutes)

 

 

  In addition to the annual requirements, replace the 

Controller’s power supply 

rechargeable battery. 
 

  Press the 

‘Fog Isolation’ button on the Controller, to inhibit fog ejection. 

 

 

‘Activate’ the 

BANDIT 320

 

by conducting a ‘dummy test’ of the intruder alarm 

system.  

Whilst ‘isolated’ a successful activation will be confirmed by the Fog 

Generator providing an audible ‘beep’ of approx. 3 seconds duration. 

 

  Reset your alarm system to normal mode 

 

 

Once completed, press the ‘Fog Isolation’ button on the controller once again, to 
return the system to normal status. 

BANDIT 320 

SERVICE & MAINTENANCE PROCEDURES 