SYMPTOM

Pilot fails to light.

Pilot lights but goes out when automatic
control valve button is released.

Maximum burn rate is low.

Soot forming inside heater, flame 100%
yellow.

Burn rate too high. Flames coming out of
emitter.

POSSIBLE CAUSE

1. Natural gas supply valve closed.
2. Air in gas line.

3. Blockage in pilot orifice.
4. Piezo ignition system not sparking.

1. Not enough warm-up time.

2. Low gas pressure.
3. Thermocouple loose or needs to be re-

placed.

4. Automatic control valve needs to be re-

placed.

1. Main burner valve not fully open.

2. Plugged gas orifices.
3. Low gas pressure.

4. Low fuel supply.

1. Main burner valve not open enough.

2. Low fuel supply

1. Pressure too high.

2. Unit connected to LP.

REMEDY

1. Open natural gas supply valve slowly.
2. Allow several minutes to purge air with

automatic control valve button de-
pressed.

3. Replace pilot orifice.
4. Adjust ignitor electrode gap to .120".

Check wire lead for damage. Replace
piezo ignitor and/or ignitor electrode as
necessary.

1. Relight, hold automatic control valve

button in 45 seconds.

2. Check for proper gas supply.
3. Tighten connection or replace thermo-

couple.

4. Replace automatic control valve.

1. Fully open main burner valve by turn-

ing the valve handle towards ON posi-
tion until it stops.

2. Replace gas orifice.
3. Check gas supply; check regulator out-

put.

4. Consult natural gas supplier.

1. Adjust amin burner valve slowly toward

ON postition until flame has more blue
color.

2. Consult natural gas supplier.

1. Check inlet pressure. If over 4 psi ad-

just or install regulator.

2. Verify gas source. If connected to LP gas,

disconnect. Connect to natural gas.

TROUBLESHOOTING

You may have further questions about this
heater. If so, contact DESA International’s
Technical Service Department at 1-800-
323-5190.

 WARNING: Never attempt to service heater while it is connected

to natural gas supply, operating, or hot. Severe burns can occur.

Summary of Contents for TC250RNG

Page 1: ...ARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CANRESULTINDEATH SERIOUSBODILYINJURYANDPROPERTYLOSSORDAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISON ING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN I...

Page 2: ...e heater serviced Natural Gas Natural gas has a distinctive odor This odor helps you detect a natural gasleak However theodormayfade Natu ral gas may be present even though no odor exists Make certain you read and understand all Warnings Keep this manual for reference It is your guide to safe and proper operation of this heater Install and use heater with care Follow all local ordinances and codes...

Page 3: ...re Feet Opening 7 5 WARNING Provide at least a 7 5 square foot opening of fresh outside air while running heater If proper fresh outside air venti lation is not provided carbon monoxide poisoning can occur Provide proper fresh outside air ventilationbeforerunningheater Theusermustfurnishthenaturalgassupply and the connections to the heater Regulate the natural gas supply down to 4 psi If over 4 ps...

Page 4: ...des when using this heater gas at 4 psi pressure for each heater connected to the system 2 Mount regulator to heater base below piezo ignitor button see Figure 2 Use 1 4 20 screws from hardware bag to at tach regulator to heater Mount regula tor so the outlet with male connector points toward the heater inlet 3 Attach the 1 2 copper fuel tube sup plied to male connector on regulator Attach other e...

Page 5: ... ignitor button see Figure 3 You may need to push the piezo ignitor button 3 8 times until the pilot lights Note Hose may be filled with air If so keep automatic control valve button pressed and wait 20 seconds for gas to clear before pressing ignitor button again When pilot lights keep automatic con trol valve button pushed in Release button after 30 seconds 5 If pilot light goes out repeat step ...

Page 6: ...ton de pressed 3 Replace pilot orifice 4 Adjust ignitor electrode gap to 120 Check wire lead for damage Replace piezo ignitor and or ignitor electrode as necessary 1 Relight hold automatic control valve button in 45 seconds 2 Check for proper gas supply 3 Tighten connection or replace thermo couple 4 Replace automatic control valve 1 Fully open main burner valve by turn ing the valve handle toward...

Page 7: ...er from natural gas supply Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s either contact your nearest Parts Central or call DESA International s Tech nical Service Department at 1 800 323 5190 When calling DESA International have ready your name how heater was malfunctioning your address purchase date model number of your heater In ...

Page 8: ...8 104133 NATURAL GAS CONSTRUCTION HEATER MODEL TC250RNG ILLUSTRATED PARTS ON OFF 4 29 5 1 3 2 6 9 10 11 12 13 14 15 16 17 18 19 21 22 23 24 26 28 27 20 25 30 7 31 8 ...

Page 9: ...lectrode 1 13 097163 07 Pilot Burner Assembly 1 14 099237 01 Thermocouple Clip 1 15 097161 01 Pilot Burner Orifice 1 16 M5788 Sleeve 1 17 M5787 Hex Nut 1 18 103028 02 Pilot Tube 1 19 097152 01 Manual Control Valve 1 20 103901 01 Burner Support 1 21 099461 01 Tee Compression Gauge 1 22 099460 01 Brass Hex Cap 1 23 097155 01 Automatic Control Valve 1 24 097157 03 Female Connector 1 25 104142 01 Fuel...

Page 10: ...____________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________...

Page 11: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Page 12: ...RRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE DESA International assumes no responsibility for indirect incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you This Limited Warranty gives you specific legal rights and you may also have other rights which var...