background image

OPERATION AND INSTALLATION

Sealed unvented (pressurised) small water heater

 

» SHC 10 AU

 

» SHC 15 AU

Содержание SHC 10 AU

Страница 1: ...OPERATION AND INSTALLATION Sealed unvented pressurised small water heater SHC 10 AU SHC 15 AU ...

Страница 2: ... 14 2 Wiring diagram 9 14 3 Heat up diagram 9 14 4 Country specific approvals and certifications 9 SPECIAL INFORMATION The appliance may be used by children aged 8 and older and persons with reduced physical sensory or mental capabilities or a lack of ex perience and know how provided that they are supervised or they have been instructed on how to use the appliance safely and have understood the r...

Страница 3: ...lt in non seri ous or minor injury 1 2 Other symbols in this documentation Note General information is identified by the adjacent symbol f f Read these texts carefully Symbol Meaning Material losses appliance damage consequential losses and environmen tal pollution Appliance disposal f f This symbol indicates that you have to do something The ac tion you need to take is described step by step 1 3 ...

Страница 4: ...the safety valve This is a necessary and normal process 4 Cleaning care and maintenance f f Never use abrasive or corrosive cleaning agents A damp cloth is sufficient for cleaning the appliance f f Check the taps regularly Limescale deposits at the tap out lets can be removed using commercially available descaling agents f f Regularly activate the safety valve to prevent it from becom ing blocked ...

Страница 5: ...st unaccept able excess pressure The maximum allowed opening pressure is 700 kPa If the water supply pressure exceeds 550 kPa a pressure reducing valve set to a maximum of 550 kPa and compliant with AS 1357 2 and installed in accordance with AS 3500 4 2 must be fitted in the installation The enamelled internal steel cylinder is equipped with a protective anode The protective anode protects the inn...

Страница 6: ...ordance with AS NZS 3500 4 f f Install either a tempering valve or thermostatic mixing valve in all systems intended for personal hygiene With this the delivery temperature for per sonal hygiene outlets must be limited to 50 C Material losses Carry out all water connection and installation work in accordance with regulations Material losses f f Never interchange the water connections f f Observe t...

Страница 7: ... from the power supply by removing the plug or by tripping the MCB in the fuse box f f Drain the appliance see chapter Installation Maintenance Draining the appliance 12 Troubleshooting Fault Cause Remedy The appliance does not supply hot water The high limit safety cut out has tripped Remedy the cause of the fault If necessary replace the com bined temperature controller high limit safety cut out...

Страница 8: ...ng the protective anode D0000050296 1 1 Protective anode f f Remove the protective anode 13 6 Fitting the flanged immersion heater and temperature controller high limit safety cut out D0000050294 f f Insert the flanged immersion heater into the cylinder aper ture well as far as it will go f f Push the combined temperature controller high limit safety cut out into the flanged immersion heater as fa...

Страница 9: ...10 AU SHC 15 AU a10 Appliance Height mm 498 523 a20 Appliance Width mm 280 320 a30 Appliance Depth mm 270 318 c01 Cold water Inlet Male thread G 1 2 A G 1 2 A Top clearance mm 26 5 23 c06 DHW outlet Male thread G 1 2 A G 1 2 A i13 Wall mounting bracket Height mm 320 342 Horizontal hole spacing mm 140 200 14 2 Wiring diagram 1 N PE 220 240 V L A B N PE 1 2 D0000035810 14 3 Heat up diagram The heat ...

Страница 10: ...PE Frequency Hz 50 60 50 60 Application limits Max permissible pressure MPa 0 7 0 7 Min water inlet pressure MPa 0 1 0 1 Max water inlet pressure MPa 0 6 0 6 Max flow rate l min 10 10 Energy data Standby energy consumption 24 h at 65 C kWh 0 5 0 53 Versions IP rating IP24 D IP24 D Type of installation Undersink Undersink Type Pressurised Pressurised Internal cylinder material Steel enamelled Steel...

Страница 11: ... operate in accordance with its specifications during the warranty period 4 If we repair or replace a faulty component to your unit under this warranty the warranty period is not extended from the time of the repair or replacement 5 The warranty period commences on the date of completion of the installation of the unit Where the date of comple tion of installation is not known then the warranty pe...

Страница 12: ...ve elements in the water supply h accidental damage i act of God including damage by flood storm fire lightning strike and the like j excessive water pressure negative water pressure par tial vacuum or water pressure pulsation 12 6 The unit was damaged before it was installed e g it was damaged in transit 12 7 An unauthorised person has modified serviced repaired or attempted to repair the unit wi...

Страница 13: ...ENGLISH www stiebel eltron com SHC 10 AU SHC 15 AU 13 NOTES ...

Страница 14: ...14 SHC 10 AU SHC 15 AU www stiebel eltron com NOTES ...

Страница 15: ...ENGLISH www stiebel eltron com SHC 10 AU SHC 15 AU 15 NOTES ...

Страница 16: ...el eltron cz Finland STIEBEL ELTRON OY Kapinakuja 1 04600 Mäntsälä Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz Cédex 3 Tel 0387 7438 88 Fax 0387 7468 26 info stiebel eltron fr www stiebel eltron fr Hungary STIEBEL ELTRON Kft Gyár u 2 2040 Budaörs Tel 01 250 6055 Fax 01 368 8097 info stiebel eltron hu www stiebel ...

Отзывы: