SAFETY  INFORMATION

1.

This appliance is only for use with the type of gas indicated on
the rating plate. This appliance is not convertible for use with
other gases unless a certified kit is used.

2.

For propane/LP burner system, do not place propane/LP supply
tank(s) inside any structure. Locate propane/LP supply tank(s)
outdoors. To prevent performance problems, do not use pro-
pane/LP fuel tank of less than 100 lbs. capacity.

3.

If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in

your building

• immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions

• if you cannot reach you gas supplier, call the fire department.

4.

Never install the stove
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable ob-

jects are less than 42" from the front, top, or sides of the
stove with burner system

• in high traffic areas
• in windy or drafty areas

IMPORTANT: Read this owner’s manual carefully
and completely before trying to assemble, operate, or
service this stove and burner system. Improper use
of this stove and burner system can cause serious
injury or death from burns, fire, explosions, electrical
shock, and carbon monoxide poisoning.

 WARNINGS

 DANGER: Carbon monoxide poisoning may lead

to death!

This stove with burner system is a vented product. This stove with
burner system will not produce any gas leakage into your home if
properly installed. This unit must be properly installed by a qualified
service person. The glass door must be properly seated and sealed. If
this unit is not properly installed by a qualified service person with glass
door properly seated and sealed, gas leakage can occur.

Carbon Monoxide Poisoning:

 Early signs of carbon monoxide

poisoning resemble the flu, with headaches, dizziness, or nausea. If
you have these signs, the burner system may not have been installed
properly.  Get fresh air at once! Have stove with burner system
inspected and serviced by a qualified service person. Some people are
more affected by carbon monoxide than others. These include preg-
nant women, people with heart or lung disease or anemia, those under
the influence of alcohol, and those at high altitudes.

 WARNING: Any change to this stove or burner

system or its controls can be dangerous.

 WARNING: This product contains and/or generates

chemicals known to the State of California to cause
cancer or birth defects, or other reproductive harm.

Natural and Propane/LP Gas:

 Natural and propane/LP gases are

both odorless. An odor-making agent is added to each of these gases.
The odor helps you detect a gas leak. However, the odor added to these
gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this
manual for reference. It is your guide to safe and proper operation
of this stove with B-vent burner system.

TABLE OF CONTENTS

SAFETY  INFORMATION ........................................................... 2

PRODUCT IDENTIFICATION ..................................................... 3

LOCAL CODES ........................................................................... 4

PRODUCT FEATURES .............................................................. 4

PRE-INSTALLATION PREPARATION ........................................ 4

CAST IRON STOVE AND B-VENT BURNER

     SYSTEM ASSEMBLY ............................................................ 5

VENTING INSTALLATION .......................................................... 9

TROUBLESHOOTING VENTING PROBLEMS ........................ 12

CAST IRON STOVE AND B-VENT BURNER

     SYSTEM INSTALLATION .................................................... 12

OPERATING STOVE WITH B-VENT BURNER SYSTEM ........ 19

INSPECTING BURNERS .......................................................... 21

CLEANING AND MAINTENANCE ............................................ 22

TROUBLESHOOTING .............................................................. 23

REPLACEMENT PARTS .......................................................... 26

TECHNICAL SERVICE ............................................................. 26

WIRING DIAGRAM ................................................................... 26

SERVICE HINTS ....................................................................... 26

SPECIFICATIONS .................................................................... 27

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST ....... 28

ACCESSORIES ........................................................................ 32

OWNER’S REGISTRATION FORM .......................................... 33

WARRANTY INFORMATION ...................................... Back Cover

TABLE OF CONTENTS
SAFETY INFORMATION

Summary of Contents for SBVBN

Page 1: ...or any other appliance Installation and service must be performed by a qualified installer service agency or the gas supplier IMPORTANT This B vent burner system must be installed into approved DESA c...

Page 2: ...operlyinstalledbyaqualifiedservicepersonwithglass door properly seated and sealed gas leakage can occur Carbon Monoxide Poisoning Early signs of carbon monoxide poisoning resemble the flu with headach...

Page 3: ...als gasoline and other flammable vapor and liquids Do not run burner system where these are used or stored Do not place items such as clothing or decorations on or around stove 12 Do not use this sto...

Page 4: ...low all local codes In the absence to local codes use the current National Fuel GasCode ANSIZ223 1 NFPA54 USA orthecurrentCAN CGA B149 1 or 2 Installation Codes Canada Available from American National...

Page 5: ...uct Identification Label Back Stove Panel CASTIRONSTOVEANDB VENT BURNER SYSTEM ASSEMBLY Pallet Wood Bolted to Bottom of Stove Body Figure 7 Laying Down Stove On Side Front of Stove Unit Top of Stove U...

Page 6: ...or leveling after stove is in normal stand ing position 12 Carefully lift stove back up on its four attached legs 13 Remove 2 bolts from bottom of stove and discard Remove bolt from the top of the sto...

Page 7: ...ure 16 2 Separate bottom cover from rear cover by loosening the 8 mounting screws see Figure 16 3 Align the holes in the top mounting tabs of blower with the holes in wall of rear cover Using the 4 sc...

Page 8: ...al switch has been properly installed to fit against back of burner system in sert after the rear cover assembly has been reinstalled 11 Make sure all wire connections to terminals on blower motor and...

Page 9: ...etal vents the most common type of vent employ double wall construction enclosing an insulating air space This air space both helps keep flue gases warm and reduce heat transferred to nearby combustib...

Page 10: ...Configuration Through Chimney Figure 24 Venting Through a Side Wall Figure 21 Typical B Vent Installation Round Top Storm Collar Flashing Roof Support 25mm 1 Clearance to Combustible Material Firesto...

Page 11: ...t access may be required NOTICE Consult the authority having jurisdiction in your area regarding listed chimney liner venting applications WARNING Operation of improperly installed and maintained vent...

Page 12: ...ge is suspected SeeChecking Gas Connection pages 14 and 15 CAUSES OF SPILLAGE AND CORRECTIVE ACTION Incorrect Vent Sizing If the vent is too small or too short spillage may occur If the vent is too la...

Page 13: ...AND B VENT BURNER SYSTEM INSTALLATION Continued Installation must include an equipment shutoff valve union and plugged1 8 NPTtap LocateNPTtapwithinreachfortestgaugehook up NPT tap must be upstream fr...

Page 14: ...uipment shutoff valve to gas supply Check reconnected fittings for leaks CHECKING GAS CONNECTIONS WARNING Test all gas piping and connections internal and external to unit for leaks after installing o...

Page 15: ...emaining wire terminal to the TH terminal on the valve Make sure that the wire termi nals are in the positions on the unit as pictured in Figure 34 If wires are not connected as shown the switch will...

Page 16: ...ermo stat no outside wall IMPORTANT The wire must not ex ceed 25 feet in length The thermostat should be mounted 54 above the floor in a location where there is good air circulation Avoid heat sources...

Page 17: ...ithout the glass door panel securely in place For replacement part infor mation see Replacement Parts page 26 1 Remove 2 bolts from bottom of stove if still installed and one from the top of stove to...

Page 18: ...ssary to use all of the lava rock provided WARNING Failure to position the parts in accor dance with these diagrams or failure to use only parts specificallyapprovedwiththisburnersystemmayresult in pr...

Page 19: ...the control system and any gas control which has been under water FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Set ON OFF switch located on re...

Page 20: ...Turns Remote On or Off and Allows You to Choose the Manual Setting Selects Auto Setting Increases Room Temperature in AUTO Mode Locks System to Prevent Accidental Ignition Digital Display Shows Temper...

Page 21: ...GWMT1 WALL MOUNTED THERMOSTAT LighttheburnersystemasinstructedinLightingInstructions on page 19 Set wall thermostat to desired temperature This thermostat has been electronically calibrated at the fac...

Page 22: ...ling Logs Lava Rock and Glowing Embers page 18 to properly replace logs Use a vacuum cleaner to remove any carbon build up on logs Replace log s if broken See Replacement Parts on page 26 Replace embe...

Page 23: ...g enough 3 Equipment shutoff valve not fully open 4 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut h...

Page 24: ...ation 1 Operate burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 2 Clean burner see Cleaning and Maintenance page 22 or replace burner orifice 1...

Page 25: ...ent above 2 Control valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked OBSERVED PROBLEM Burner system prod...

Page 26: ...r servicing REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of thi...

Page 27: ...pply Pressure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Stove and Burner System 27 x 26 1 4 x 20 27 x 26 1 4 x 20 685 8 x 660 4 x 635mm 685 8 x 660 4 x 635mm Carton Insert On...

Page 28: ...more information visit www desatech com 28 ILLUSTRATED PARTS BREAKDOWN MODELS SBVBN C AND SBVBP C 4 4 17 18 19 21 23 1 23 4 23 2 23 3 27 4 22 10 16 11 8 1 25 25 4 13 14 20 20 4 5 3 6 26 2 24 7 12 15...

Page 29: ...l Switch 1 17 106036 01 Burner Natural 1 106036 02 Burner Propane LP 1 18 104506 16 Orifice Natural 1 104506 17 Orifice Propane LP 1 19 14528 Brass Elbow 1 20 901056 01 Brass Elbow 2 21 101628 04 Flex...

Page 30: ...om For more information visit www desatech com 30 ILLUSTRATED PARTS BREAKDOWN AMITY SCIVFC SERIES PSCIVFC SERIES Indicates Color Suffix Designation 2 5 8 7 4 6 5 5 7 1 7 2 5 4 7 3 1R 1C 1L 3 ILLUSTRAT...

Page 31: ...175 05 One Leg Forest Green 4 Total Per Stove 1 104175 06 One Leg Metallic Charcoal 4 Total Per Stove 1 104175 07 One Leg Porcelain Enamel Red 4 Total Per Stove 1 104175 08 One Leg Porcelain Enamel Te...

Page 32: ...L MOUNTED THERMOSTAT CONTROL KIT GWMT1 Not Shown For all models Allows easy wall access to the operation of your burner system This will allow you thermostatic control with the convenience of a wall s...

Page 33: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Page 34: ...106828 01C For more information visit www desatech com For more information visit www desatech com 34 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Page 35: ...________________________________________________________ _______________________________________________________________________________________________ _______________________________________________...

Page 36: ...stic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTIO...

Reviews: