background image

17

107340

OWNER’S MANUAL

Baltimore Electric

1348 Dixwell Avenue
Hamden, CT 06514-0322
1-800-397-7553
203-248-7553
Parts Department

Portable Heater Parts

342 N. County Rd. 400 East
Valparaiso, IN 46383-9704
All States
219-462-7441
1-800-362-6951
[email protected]
[email protected]

FBD

1349 Adams Street
Bowling Green, KY 42103-3414
270-846-1199
1-800-654-8534
Fax: 1-800-846-0090
[email protected]

Master Parts Dist.

1251 Mound Ave. NW
Grand Rapids, MI 49504-2672
616-791-0505
1-800-446-1446
Fax: 616-791-8270
www.nbmc.com

Washer Equipment Co.

1715 Main Street
Kansas City, MO 64108-2195
KS, MO, AR
816-842-3911
www.washerparts.com

East Coast Energy Products

707 Broadway
W. Long Branch, NJ 07764-1542
732-870-8809
1-800-755-8809
www.njplaza.com/ecep

Tarantin Tank Co.

P.O. Box 6129
Freehold, NJ 07728-6129
908-780-9340
1-800-922-0724
www.tarantin.com

Heater and Fireplace Store

58 Halbe Lane
Cape May Court, NJ 08210-1110
609-390-9774
Parts Department

Dayton Hardware

P.O. Box 275
North Dayton Station
Dayton, OH 45404-0275
All States
937-258-3721
OH 1-800-762-3426

Halco Enterprises

208 Carter Drive, Unit 21
West Chester, PA 19382-4500
610-430-7717
1-800-368-0803
www.halcoenterprises.com

Laportes Parts & Service

2444 N. 5th Street
Hartsville, SC 29550-7704
803-332-0191
Parts Department

Cans Unlimited, Inc.

P.O. Box 645
Taylor, SC 29687-0013
All States
803-879-3009
1-800-845-5301
[email protected]

PARTS CENTRALS

These Parts Centrals are privately owned businesses. They have agreed to support our
customer's needs by providing original replacement parts and accessories.

SPECIFICATIONS

FGHS30NGB

Btu (Variable)

30,000/15,000

Type Gas

Natural Only

Ignition

Piezo

Pressure Regulator Setting

3" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

Minimum

4"

Dimensions, Inches (H x W x D)

Heater  (Includes knobs & grill)

23 x 26 x 7

Carton

26 x 28.5 x 9

Weight (pounds)

Heater

28.1

Shipping

34.1

Summary of Contents for Glo-Warm FGHS30NGB

Page 1: ...rformed by a qualified installer service agency or the gas supplier Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This is an unvented gas fired heater It uses...

Page 2: ...ilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation...

Page 3: ...If heater is damaged promptly inform dealer where you bought heater Figure 1 Vent Free Natural Gas Heater Ignitor Button Control Knob Heater Cabinet Front Panel PRODUCT FEATURES SAFETY DEVICE This he...

Page 4: ...ion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings expos...

Page 5: ...include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr use...

Page 6: ...atticwillactivatethepowervent AIR FOR COMBUSTION AND VENTILATION Continued Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 12 12 Ventilation Grills into Adj...

Page 7: ...n and Ventilation pages 4 through 6 CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or...

Page 8: ...et Removing Front Panel Of Heater 1 Remove two screws near bottom cor ners of front panel 2 Liftstraightupongrillguarduntilitstops Grill guard will slide up about 1 4 3 Pull bottom of front panel forw...

Page 9: ...acket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Figure 12 Installing Bottom Mounting Screws Figure 10 Popping Open Anchor Wings For Thin Walls Figure 11...

Page 10: ...alled wrong heater may not run properly IMPORTANT Holdpressureregulatorwith wrench when connecting it to gas piping and or fittings CAUTION Use only new black iron or steel pipe Inter nally tinned cop...

Page 11: ...ent shutoff valve see Figure 14 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to thermost...

Page 12: ...theequip ment shutoff valve Figure 17 Pilot LIGHTING INSTRUCTIONS 1 STOP Read the safety information column 3 page 11 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise Cl...

Page 13: ...ol areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent clea...

Page 14: ...llowing A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cab...

Page 15: ...em will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas c...

Page 16: ...g statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED P...

Page 17: ...2 0724 www tarantin com Heater and Fireplace Store 58 Halbe Lane Cape May Court NJ 08210 1110 609 390 9774 Parts Department Dayton Hardware P O Box 275 North Dayton Station Dayton OH 45404 0275 All St...

Page 18: ...BLUE FLAME NATURAL GAS HEATER ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODEL FGHS30NGB 7 7 5 2 5 27 22 26 23 19 17 24 25 12 26 21 20 18 9 8 18 16 10 16 13 1 14 14 15 7 6 11 3 7 4 7 7 24 1 24 2 ODS Pilot...

Page 19: ...1 097159 04 Ignitor 1 12 L98411 01 Ignitor Line 1 13 L99029 03 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98115 03 Main Inlet Tube Assembly 1 17 L98123 06 ODS Lin...

Page 20: ...produce specified heat When Gas Quality Is Bad pilot will not stay lit burner will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so c...

Page 21: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 22: ...oids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not...

Reviews: