manualshive.com logo in svg
background image

1

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

WARNING

FOR YOUR SAFETY - READ BEFORE OPERATING

This product must be installed and serviced by a professional service technician qualified in pool/spa heater installation and
maintenance. Some jurisdictions require that installers be licensed. Check with your local building authority about contractor
licensing requirements. Improper installation and/or operation could create carbon monoxide gas and flue gases which could
cause serious injury or death. Improper installation and/or operation will void the warranty. Call 1.800. 664. 266 for additional
free copies of these instructions.

WARNING

Failure to follow instructions could result in fire or explosion with serious personal injury or property damage. This orifice
replacement kit or this fuel gas conversion kit is to be installed by a Pentair distributor or other qualified agency in accordance
with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. The information in
these instructions must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury,
or death. The qualified service agency performing this work is responsible for the proper installation of this kit and assumes
responsibility for this replacement.

Pentair Water Pool and Spa, Inc. EMEA

 – 

Head Office: Industriepark,

 

Wolfstee, Toekomstlaan 30, 2200 Herentals - Belgium.

Pentair Water Pool and Spa, Inc. AU/NZ

 – 

Head Office: 1-21 Monash Drive, Dandenong South, Victoria 3175

– Australia • +61 (0)400.825.002 • 1300.137.344

Pentair Water Pool and Spa, Inc. USA 

 –

 1620 Hawkins Ave., Sanford, NC 27330, USA • (919) 566-8000 • (800) 831-7133

10951 W. Los Angeles Ave., Moorpark, CA 93021, USA • (805) 553-5000 • (800) 831-7133

www. pentaireurope.com - www.pentairwater.com.au - www.pentairpool.com - www.staritepool.com

DANGER

CARBON MONOXIDE GAS IS DEADLY – 

Exhaust from this pool heater contains carbon monoxide, a dangerous,

poisonous gas you cannot see or smell. Symptoms of carbon monoxide exposure or poisoning include dizziness,
headache, nausea, weakness, sleepiness, muscular twitching, vomiting and inability to think clearly. IF YOU EXPERIENCE
ANY OF THE ABOVE SYMPTOMS, IMMEDIATELY TURN OFF THE POOL HEATER, LEAVE THE VICINITY OF THE
POOL OR SPA AND GET INTO FRESH AIR IMMEDIATELY. THE POOL HEATER MUST BE THOROUGHLY TESTED
BY A GAS PROFESSIONAL BEFORE RESUMING OPERATION.

EXCESSIVE CARBON MONOXIDE EXPOSURE CAN CAUSE BRAIN DAMAGE OR DEATH.

Pentair strongly recommends that all vents, pipes and exhaust systems be initially and periodically tested for proper
operation. This testing can be accomplished by using a hand-held carbon monoxide meter and/or by consulting with a gas
professional.

Pool heaters must be used in conjunction with carbon monoxide detectors installed near the pool heater. The carbon monoxide
detectors must be periodically inspected for proper operation so as to insure continued safety. Broken or malfunctioning
carbon monoxide detectors must be replaced immediately.

This fuel gas conversion kit is for the purpose of converting a Pentair Water Pool and Spa

®

 MasterTemp

™ 

 heater from Natural Gas (NG) to Propane

(LP). It is not designed to alter the input to the appliance and must not be used to attempt to alter the input from the original nameplate rating. The term
“qualified agency” means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible
for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such
work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction. A Pentair distributor with
service personnel trained to install or repair gas heaters is a qualified agency.

P/N 474229 Rev B 12-5-14

GAS ORIFICE REPLACEMENT KIT & FUEL GAS CONVERSTION KIT (NG TO LP) - (LP TO NG)
INSTALLATION INSTRUCTIONS

MASTERTEMP™  HEATER

Содержание MASTERTEMP

Страница 1: ...ater contains carbon monoxide a dangerous poisonous gas you cannot see or smell Symptoms of carbon monoxide exposure or poisoning include dizziness headache nausea weakness sleepiness musculartwitching vomitingandinabilitytothinkclearly IFYOUEXPERIENCE ANY OF THE ABOVE SYMPTOMS IMMEDIATELY TURN OFF THE POOL HEATER LEAVE THE VICINITY OF THE POOL OR SPA AND GET INTO FRESH AIR IMMEDIATELY THE POOL HE...

Страница 2: ...ves and a negative pressure regulator For proper operation the regulated pressure at the outlet manifold of the valve must be 110 50 mbar 11 5 kPa below the reference pressure at the blower mixer inlet and the gas valve VENT tap must be connected to the end cap air orifice as shown in Figure 1 DO NOT attempt to adjust the gas input by adjusting the regulator setting The correct gas regulator setti...

Страница 3: ...e tap 11 Open the gas supply to the heater 12 Verify that the seal connection in the pressure tap is closed by testing for leaks with soapy water Note If the pressure reading is out of range regulate the incoming gas pressure see Table below Table 1 Inlet Gas Pressure Requirements e r u s s e r P s a G m u m i n i M m u m i x a M s a G l a r u t a N r a b m 0 1 a P k 0 1 r a b m 0 6 a P k 0 6 s a ...

Страница 4: ...bel from Step 11 Remove Orifice 2 5X Install O Ring and new Orifice then Reconnect the Gas Line Union Figure 3 Install new Orifice and Reconnect Union Kit No Model No ID Stamp 474142 200HD Convert NG to LP LQ 474141 300HD Convert NG to LP LN 474140 400HD Convert NG to LP LK 474145 200HD Convert LP to NG NH 474144 300HD Convert LP to NG NE 474143 400HD Convert LP to NG NB Fuel Gas Conversion Kits N...

Страница 5: ... backing strip and apply the label with uniform pressure over the entire surface see Figure 4 APPELER LE SERVICE A LA CLIE POUR VALIDER VOTRE GARA FOR CUSTOMER SERVIC CALL OU POUR 1 800 831 7133 COMPOSEZ LE 1 800 831 7133 OR ge MOORPARK CA 93021 FOR YOUR SAFETY Specifications Inlet Pressure Natural Gas Propane Gas Max 60 mbar 6 0 kPa 60 mbar 6 0 kPa Min 10 mbar 1 0 kPa 25 mbar 2 5 kPa Manifold Pre...

Страница 6: ...6 Blank Page ...

Страница 7: ...7 Blank Page ...

Страница 8: ...s that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those third parties Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice...

Отзывы: