background image

7

107340

OWNER’S MANUAL

36"

16.75"

FLOOR

CEILING

Minimum

Minimum to Top 
of Carpeting, Tile,
or Other Combustible 
Material

6"

Minimum
From
Sides of
Heater

Left
Side

Right
Side

INSTALLATION

Continued

CHECK GAS TYPE

Use only natural gas. If your gas supply is not
natural, do not install heater. Call dealer where
you bought heater for proper type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below:

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• ground joint union

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional CSA design-certified
equipment shutoff valve from your dealer.
See Accessories, page 20.

 WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

 WARNING: Maintain the mini-

mum clearances shown in Figure
4. If you can, provide greater clear-
ances from floor, ceiling, and join-
ing wall.

 CAUTION: If you install the

heater in a home garage
• heater pilot and burner must be

at least 18 inches above floor

• locate heater where moving ve-

hicle will not hit it

IMPORTANT: 

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, 
pages 4 through 6.

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

 WARNING: Never install the

heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

You can locate heater on floor, away from a
wall. An optional floor mounting stand is
needed. Purchase the floor mounting stand
from your dealer. See Accessories, page 20.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

LOCATING HEATER

This heater is designed to be mounted on a wall.

Figure 4 - Mounting Clearances As Viewed
From Front of Heater

For convenience and efficiency, install heater

• where there is easy access for operation,

inspection, and service

• in coldest part of room

An optional fan kit is available from your
dealer. See Accessories, page 20. If planning to
use fan, locate heater near an electrical outlet.

Summary of Contents for Glo-Warm FGHS30NGB

Page 1: ...rformed by a qualified installer service agency or the gas supplier Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This is an unvented gas fired heater It uses...

Page 2: ...ilation to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation...

Page 3: ...If heater is damaged promptly inform dealer where you bought heater Figure 1 Vent Free Natural Gas Heater Ignitor Button Control Knob Heater Cabinet Front Panel PRODUCT FEATURES SAFETY DEVICE This he...

Page 4: ...ion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings expos...

Page 5: ...include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr use...

Page 6: ...atticwillactivatethepowervent AIR FOR COMBUSTION AND VENTILATION Continued Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 12 12 Ventilation Grills into Adj...

Page 7: ...n and Ventilation pages 4 through 6 CAUTION This heater cre ates warm air currents These currents move heat to wall sur faces next to heater Installing heater next to vinyl or cloth wall coverings or...

Page 8: ...et Removing Front Panel Of Heater 1 Remove two screws near bottom cor ners of front panel 2 Liftstraightupongrillguarduntilitstops Grill guard will slide up about 1 4 3 Pull bottom of front panel forw...

Page 9: ...acket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Figure 12 Installing Bottom Mounting Screws Figure 10 Popping Open Anchor Wings For Thin Walls Figure 11...

Page 10: ...alled wrong heater may not run properly IMPORTANT Holdpressureregulatorwith wrench when connecting it to gas piping and or fittings CAUTION Use only new black iron or steel pipe Inter nally tinned cop...

Page 11: ...ent shutoff valve see Figure 14 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to thermost...

Page 12: ...theequip ment shutoff valve Figure 17 Pilot LIGHTING INSTRUCTIONS 1 STOP Read the safety information column 3 page 11 2 Make sure equipment shutoff valve is fully open 3 Turn control knob clockwise Cl...

Page 13: ...ol areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent clea...

Page 14: ...llowing A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cab...

Page 15: ...em will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas c...

Page 16: ...g statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED P...

Page 17: ...2 0724 www tarantin com Heater and Fireplace Store 58 Halbe Lane Cape May Court NJ 08210 1110 609 390 9774 Parts Department Dayton Hardware P O Box 275 North Dayton Station Dayton OH 45404 0275 All St...

Page 18: ...BLUE FLAME NATURAL GAS HEATER ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODEL FGHS30NGB 7 7 5 2 5 27 22 26 23 19 17 24 25 12 26 21 20 18 9 8 18 16 10 16 13 1 14 14 15 7 6 11 3 7 4 7 7 24 1 24 2 ODS Pilot...

Page 19: ...1 097159 04 Ignitor 1 12 L98411 01 Ignitor Line 1 13 L99029 03 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98115 03 Main Inlet Tube Assembly 1 17 L98123 06 ODS Lin...

Page 20: ...produce specified heat When Gas Quality Is Bad pilot will not stay lit burner will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so c...

Page 21: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 22: ...oids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not...

Reviews: