background image

 

 

ELECTRIC FIREPLACE 

INSTALLATION INSTRUCTIONS 

Models: (V)E32L, (V)E32LB, (V)E32LH, (V)E32LBH 

(V)E36L, (V)E36LB, (V)E36LH and (V)E36LBH

 

 

 

 

Servicing Flame Pennants 

 

If the flame pennants should become tangled or detached they may 

be reattaching or replacing as follows: 

 

1.  Locate the affected flame pennant and slip the hem at the base 

of the flame pennant over the proper hanger bracket position. 

See 

Figure 38

 for proper location. 

 

2.  Pull the flame cord up to the proper hook location, use a slip 

knot to adjust the cord length and attach the cord to the hook. 

See 

Figure 38

 for proper cord length. 

 

3.  Tie another knot over the slip knot and trim away access cord. 

 

Note

: The flame pennant should not be twisted or tangled and 

should hang slightly loose to allow free movement. If the cord is 

too short or the pennant is torn you must obtain a replacement 

flame assembly, See 

Replacement Parts

, page 

19

.   

 

4.  After connecting and adjusting the flame cords, soak each knot 

with a drop of white wood glue or clear nail polish to prevent 

them from unraveling. 

 

   

Replacing Lamp Fixtures 

 

Lamp fixtures may be replaced as follows: 

 

1.  Turn off all power to the appliance at the circuit breaker or fuse. 

 

2.  Locate any of 3 defective lamp fixtures and trace the wiring to 

the crimp connections. See 

Figure 39

 

3.  Remove the 2 crimp connectors in the harness and disconnect 

the 

white

 and 

black

 wires on the defective fixture. See 

Wiring 

Diagram

Figure 28,

 page 

12

 for proper locations. 

 

4.  Remove the 2 Phillips screws at the base of the defective fixture 

(see 

Figure 39

). 

 

5.  Remove the old fixture and remount the new fixture with the 2 

Phillips screws removed prior.  

 

6. Twist the bare ends of the 

white

 and 

black

 wires to the 

corresponding wires in the main harness and secure them with 

the 2 crimp connectors provided. 

 

Note

: There should be no exposed bare wire at any connection. 

Wiring should be secured with wire ties, as short as possible and 

kept away from the fan blades. If additional parts are required, see 

Replacement Parts

, page 

19

 

6.  Replace each light bulb with the proper color, see 

Replacing 

Light Bulbs

, page 

13

 

7. Restore power and check the lamp circuit operation, before 

reassembling the imaging unit. 

 

8.  Reassemble the imager. See 

Accessing Imaging Unit

, page 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 

IMPORTANT:

 Be sure to inspect the components and wiring 

for damage before connecting power to the unit. If any 

components are found damaged, contact an authorized dealer 

for original DESA replacement part(s) or call DESA at 1-866-

872-6040 for referral. 

 

 

 

 

3 1/2"

CORD

FLAME

PENNANT

FLAME

8"

7"

1 1/2"

SPACER

FLAME

 

Figure 38 - Locating the Flame Pennants 

17 

RIBBON

REFLECTIVE

HANGER
SCREWS

LAMP
FIXTURE

(2) SCREWS

CRIMP
CONNECTORS

SCREWS &
WASHERS

Figure 39 - Replacing Fixtures 

Make sure the power is turned off at the 
supply prior to disassembling this unit.

 

F

F

o

o

r

r

 

 

m

m

o

o

r

r

e

e

 

 

i

i

n

n

f

f

o

o

r

r

m

m

a

a

t

t

i

i

o

o

n

n

,

,

 

 

v

v

i

i

s

s

i

i

t

t

 

 

w

w

w

w

w

w

.

.

d

d

e

e

s

s

a

a

t

t

e

e

c

c

h

h

.

.

c

c

o

o

m

m

 

 

111076-01C

 

Summary of Contents for E32, VE36, VE32

Page 1: ...E READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE ____________________________________ WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT C...

Page 2: ...osed space where exposed to the elements 10 To disconnect this appliance it must be turned off at the branch circuit breaker 11 This appliance when installed must be electrically grounded in accordanc...

Page 3: ...on an existing finished wall Corner installations make use of space that may not normally be used and provides wider and more efficient heat distribution Internal wall installations provide a discree...

Page 4: ...re inserting firebox into opening See instructions included with the trim kit If installing a mantel above the firebox you must follow clearance instructions see Installation Clearances page 3 4 7 0 E...

Page 5: ...versal strain relief bushing in the remaining cover 10 Strip back the outer Romex to about 4 and connect the black white and green wires accordingly using approved connectors 11 Tuck the tailing wires...

Page 6: ...n added circulating heater rated at 1100 W In addition to a heater the models E36 32LB and E36 32LBH include a hand detailed textured red brick lining Models VE36 32LB and VE36 32LBH come standard wit...

Page 7: ...eserving the noted gap at each edge 10 Repeat the process until both doors are evenly joined spaced and working freely Removing Bi Fold Glass Doors Bi fold doors may be removed for replacing or cleani...

Page 8: ...he brick panel and secure with 2 pan screws provided 7 Replace the face extension using the 2 screws removed prior 8 Repeat steps 5 through 7 for the opposite panel assembly 9 Replace each screen asse...

Page 9: ...n blower mount and attach with 4 pan head screws provided See Figures 21 or 22 9 With the discharge pointing towards you guide the assembled blower mount into the firebox and center the rear mounting...

Page 10: ...l locked into position See Figure 20 page 9 21 Tuck any excess slack in harnesses into control cover swing cover down to line up mounting holes on control panel and replace the 2 Phillips screws remov...

Page 11: ...ctive switch See Servicing Control Panel page 14 3 Check connections from main power harnesses to terminals on control panel See Servicing Control Panel page 14 1 Inspect flame pennants untangle or re...

Page 12: ...PLOYER DES FILS D ALIMENTATION AD QUATS POUR 105 C OU QUIVALENT CAUTION DISCONNECT APPLIANCE FROM THE ELECTRICAL SUPPLY BEFORE REMOVING THIS COVER ATTENTION D CONNECTER L APPAREIL DU CIRCUIT D ALIMENT...

Page 13: ...l cleaning and or vacuuming around the heater and fan unit is recommended Removing Replacing Control Door The upper control door may be removed for service or replacement when necessary 1 Open the upp...

Page 14: ...sses free from the control cover See Figure 30 6 Remove the magnet assemblies discharge deflector and control door See Removing Replacing Control Door page 13 7 Tilt entire control assembly forward un...

Page 15: ...ening See Figure 33 5 Remove the 4 Phillips screws holding the face extensions at the top refractory clips See Figure 34 6 Remove the viewing screen from the cabinet face The viewing screen is attache...

Page 16: ...t it out of the unit 5 Remove the 4 nut and bolt combinations from the fan housing 6 Remount the new fan to the blower mount in reverse order 7 Slide the blower assembly with spacers over the mounting...

Page 17: ...k wires on the defective fixture See Wiring Diagram Figure 28 page 12 for proper locations 4 Remove the 2 Phillips screws at the base of the defective fixture see Figure 39 5 Remove the old fixture an...

Page 18: ...tive ribbon 8 If replacing the reflective ribbons located in the base remove the screws and washers at the damaged ends of the ribbon 9 Cut a 9 inch long strip of ribbon and apply across each ribbon s...

Page 19: ...out installation operation or troubleshooting If so contact DESA Technical Service Department at 1 866 672 6040 When calling please have your model and serial numbers of your fireplace ready You can a...

Page 20: ...RUCTIONS Models V E32L V E32LB V E32LH V E32LBH V E36L V E36LB V E36LH and V E36LBH ILLUSTRATED PARTS BREAKDOWN Models E36L E36LB E36LH and E36LBH E32L E32LB E32LH and E32LBH VE36L VE36LB VE36LH and V...

Page 21: ...hing Strain Relief Universal 1 20 112075 01 112075 01 112075 01 112075 01 Retainer Refractory 2 21 110794 01 110794 01 110794 01 110794 01 Junction Box 1 22 11102 11102 11102 11102 Screw 8 32 x 3 8 Ph...

Page 22: ...RUCTIONS Models V E32L V E32LB V E32LH V E32LBH V E36L V E36LB V E36LH and V E36LBH ILLUSTRATED PARTS BREAKDOWN Models E36L E36LB E36LH and E36LBH E32L E32LB E32LH and E32LBH VE36L VE36LB VE36LH and V...

Page 23: ...279 01 Washer M4 22 5mm Flat 4 21 114266 01 114266 01 114266 01 114266 01 Screw M4 12mm Phillips Pan 3 22 114267 01 114267 01 114267 01 114267 01 Washer M4 9mm Flat 4 23 114268 01 114268 01 114268 01...

Page 24: ...ss BD36P 36 Bi Fold Glass Doors Platinum BD32 32 Bi Fold Glass Doors Black BD32B 32 Bi Fold Glass Doors Brushed Brass BD32PB 32 Bi Fold Glass Doors Polished Brass BD32P 32 Bi Fold Glass Doors Platinum...

Page 25: ...TRUCTIONS Models V E32L V E32LB V E32LH V E32LBH V E36L V E36LB V E36LH and V E36LBH INSTALLATION NOTES 25 F Fo or r m mo or re e i in nf fo or rm ma at ti io on n v vi is si it t w ww ww w d de es sa...

Page 26: ...THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO ONE 1 YEAR ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE AND DESA S...

Reviews: