OWNER’S MANUAL

LOCAL CODES

UNPACKING

1.

Remove furnace from carton.

2.

Remove all protective packaging ap-
plied to furnace for shipment.

3.

Remove the following items from carton:
• Hardware package containing four

large screws, two small screws, and
thermostat mounting plate

• Hardware package (thermostat and

two screws)

• Equipment shutoff valve

If any of these items are missing,
promptly inform dealer where you
bought furnace.

4.

Check furnace for any shipping damage.
If furnace is damaged, promptly inform
dealer where you bought furnace.

PRODUCT
FEATURES

HOT SURFACE IGNITOR

This furnace has an electronic ignitor. There
is no standing pilot. No matches or batteries
are required.

THERMOSTATIC HEAT
CONTROL

The thermostat is temperature sensitive. It
automatically turns the furnace on and off.
This results in the greatest heating comfort.
This can also result in lower gas bills.

LIMIT SWITCH

The limit switch shuts off the gas to the main
burner if the furnace becomes too hot to
operate safely.

DNV25PB

DNV40PB

*Rated Heating Input (BTU/Hr)

25,000

40,000

Thermal Output Capacity

(average loss calculation)

18,750 Btu/Hr

30,000 Btu/Hr

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Hot Surface Ignitor

Hot Surface Ignitor

Operating Amps

1.5

2

Volts/Cycles

120/60

120/60

Main Burner

1

2

Pressure Regulator Setting

10" W.C.

10" W.C.

Inlet Connection

3/8 NPT

3/8 NPT

Inlet Gas Pressure (in. of water)*

Maximum

13"

13"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

Furnace

15 

3

/

32

 x 16 

1

/

8

 x 23 

5

/

8

15 

3

/

32

 x 21 

3

/

4

 x 23 

5

/

8

Weight (pounds)

Furnace

53

71

Shipping

65

98

* For purposes of input adjustment.

SPECIFICATIONS

Install and use furnace with care. Follow all
local codes. In the absence of local codes, use
the latest edition of the following:

• National Fuel Gas Code ANS Z223.1,

also known as NFPA 54 * (USA)

• National Electric Code ANS/NFPA 70*

• CAN/CGA-B149[.1 or .2] Installation

Codes** (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA  02269

**Available from:

Standards Council of Canada

350 Sparks Street

Ottawa, Ontario  K1R 7S8

This furnace must be grounded when in-
stalled. Follow all local codes. In the ab-
sence of local codes, refer to the National
Electrical Code ANS/NFPA No. 70
 (U.S.A.)
or  CSA C22.1 Canadian Electrical Code,
Part I 
(Canada).

The installation must conform with local
codes, in the absence of local codes, with the
National Fuel Gas Code, ANS Z223.1/Ca-
nadian Installation Code, CAN/CGA B149.

When installing furnace in a manufactured
(mobile) home, follow the Manufactured
Home Construction and Safety Standard,
Title 24CFR, Part 3280 (formerly the Fed-
eral Standard for Mobile Home Construc-
tion and Safety, Title 24, part 280; 1975)
.
When such a standard is not applicable,
follow the Standard for Manufactured Home
Installations, 1982 (Manufactured Home
Sites, Communities, and Set-Ups), ANS
A225.1/NFPA 501A.

In Canada, install furnace in accordance with
Standard CSA Z240.4 - Gas Equipped Recre-
ational Vehicles and Mobile Housing
 and
any applicable local codes and regulations.

Appliance input ratings are based on sea
level operation and need not be changed for
operation up to 2,000 feet elevation. For
operation at elevations above 2,000 feet,
manufactured to specified deration condi-
tions for Canada and the United States.

Summary of Contents for DYNAVENT DNV25PB

Page 1: ...NING Improperin stallation adjustment alteration service or maintenance can cause injury or property dam age Refertothismanual for correct installation and operational proce dures Forassistanceor addi...

Page 2: ...LP gas is odor less An odor making agent is added to pro pane LP gas The odor helps you detect a propane LPgasleak However theodoradded to propane LP gas can fade Propane LP gas may be present even t...

Page 3: ...For purposes of input adjustment SPECIFICATIONS Install and use furnace with care Follow all localcodes Intheabsenceoflocalcodes use the latest edition of the following National Fuel Gas Code ANS Z223...

Page 4: ...installing thermostat in a wall make sure there are no pipes or wiring in the hollow wallabovethefurnace Thethermostatwires will pass through this wall from the attic Mounting hardware needed to moun...

Page 5: ...000 BTU Hr Model Use a proper sized drill bit Drill holes through wall and into studs at marked locations 40 000 BTU Hr Model Use a proper sized drill bit On wall stud side of opening drill holes thro...

Page 6: ...else that would interfere with install ing thermostat Do not mount thermo stat to stud If there are any obstruc tions choose a new location 3 Provide two 18 gauge insulated stranded wires for the the...

Page 7: ...t Wires to Thermostat Wall Anchors CAUTION Use only new black iron or steel pipe Copper tubing may be acceptable in cer tain areas Check local codes Use pipe large enough in diam eter to allow proper...

Page 8: ...de furnace back into furnace cabi net Make sure exhaust tube gaskets are in place Make sure exhaust and intake vent tubes extend into vent caps on back of cabinet Replace two screws by exhaust vent s...

Page 9: ...0 BTU Hr 15 000 BTU Hr for other gas appliances 55 000 BTU Hr total 55 000 2500 22 Locate 22 or higher on chart below According to the chart below you should use 40 feet or less of 3 8 pipe 125 feet o...

Page 10: ...5 CAUTION Usepipejointseal ant that is resistant to liquid pe troleum LP gas Slab Floor Installation Equipment Shutoff Valve Test Gauge Connection To Gas Supply 3 Min Sediment Trap Gas Piping Entering...

Page 11: ...0 cycle grounded outlet at furnace location 2 The furnace has a three pronged grounded plug Use only a grounded three prong outlet IMPORTANT Some local codes require rigid or semi rigid conduit or met...

Page 12: ...Do not try to light the burner by hand 8 Plug in furnace 9 Set thermostat to desired setting If thermostat is set above room tem perature the blower will come on 10 Allow approximately 45 seconds for...

Page 13: ...forces the combus tion products out of the exhaust tube s The Combustion air blower is sealed so that air does not pass between it and the circulating room air blower 3 When the blower motor reaches...

Page 14: ...r mixture Wipe cabinet and front cover to remove dust Use a vacuum cleaner to remove dust from front cover louvers EXHAUST AND INTAKE VENTS Make sure the exhaust and intake vents are not blocked The i...

Page 15: ...okay check for defective motor 5 Be sure the microswitch is sailing in far enough to open the solenoid valve and to energize the ignition control If the switch is not sailing in clean any dust or dir...

Page 16: ...t it WARNINGS Never connect unit or ignition circuit to 230 volts Never operate unit with glo bar touching burner or any other ground Damage to ignition control will occur Be sure sensor probe never t...

Page 17: ...bar broken 2 A Check for voltage 24 volts A C at valve 40 seconds after glo bar begins to glow If voltage present but valve not opening replace valve B If no voltage at valve check brown wire at igni...

Page 18: ...Be sure probe is positioned in the burner flame and glowing cherry red Check wire and wire connections at probe and ignition control B If wire and wire connections okay check for voltage across brown...

Page 19: ...hite Open WIRING DIAGRAMS Figure 21 Wiring Diagram 40 000 BTU Hr Model Figure 20 Wiring Diagram 25 000 BTU Hr Model Note Use only original replacement parts Thiswillprotectyourwarrantycoveragefor part...

Page 20: ...41 www portableheaterparts com sales portableheaterparts com techservice portableheaterparts com F B D 1349 Adams Street Bowling Green KY 42103 3414 1 800 654 8534 270 846 1199 Fax 1 800 846 0090 fran...

Page 21: ...1244 Operating Instructions Decal English 1 191246 Operating Instructions Decal French 1 531010 Warning Decal 1 191262 Nameplate 1 Parts available not shown You must order nameplate and operating inst...

Page 22: ...8 x 3 8 2 3 191241 Front Cover Trim 1 4 030642 Front Cover Assembly 1 5 100896 Cabinet Assembly 1 6 070511 Cabinet Insulation right and left sides 1 7 120158 Screw 8 x 3 8 2 8 160912 Thermostat inclu...

Page 23: ...44 Terminal Block 1 10 121224 Screw 10 x 3 4 2 11 070487 Gasket 1 12 231143 Transformer Assembly 1 13 121252 Screw 10 x 3 8 6 14 020983 Combustion Chamber Heat Shield Assembly 1 15 070606 Heat Shield...

Page 24: ...Terminals 1 13 070607 Heat Shield Gasket 1 14 020982 Combustion Chamber Heat Shield Assembly 1 15 061663 Wire Clamp 2 16 121252 Screw 10 x 3 8 12 17 230560 Limit Switch 1 KEY PART NO NUMBER DESCRIPTIO...

Page 25: ...3 4 5 6 7 8 9 10 11 12 KEY PART NO NUMBER DESCRIPTION QTY 1 120717 Hex Nut 10 24 2 2 121459 Screw 10 24 x 1 2 2 3 010701 Burner Assembly 1 4 180215 Main Burner Orifice 1 5 121388 Screw 10 x 1 2 4 6 07...

Page 26: ...PART NO NUMBER DESCRIPTION QTY 1 120717 Hex Nut 10 24 4 2 010621 Left Burner Assembly 1 3 010623 Right Burner Assembly 1 4 070591 Manifold Gasket 1 5 171167 Manifold Assembly 1 6 180188 Main Burner Or...

Page 27: ...oom air 1 8 121421 Hex Lock Nut 10 24 3 9 050751 Crossover Tube 1 10 121388 Screw 10 x 1 2 4 11 070385 Crossover Tube Gasket 2 12 121227 Screw 10 24 x 1 2 2 13 070362 Universal Bushing 1 14 231231 Cap...

Page 28: ...ombustion Air Cover Assy 1 12 121388 Screw 10 x 1 2 3 13 070420 Combustion Air Crossover Gasket 1 14 390318 Combustion Air and Motor Cover Assembly 1 KEY PART NO NUMBER DESCRIPTION QTY 15 121227 Screw...

Page 29: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 30: ...lity of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DU...

Reviews: