TROUBLESHOOTING

 WARNING: Turn off heater

and let cool before servicing. Only
a qualified service person should
service and repair heater.

 CAUTION: Never use a wire,

needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.

POSSIBLE CAUSE

1. Ignitor electrode not connected to igni-

tor cable

2. Ignitor cable pinched or wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned wrong

1. Gas supply turned off or equipment

shutoff valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. ODS/pilot is clogged

6. Gas regulator setting is not correct

1. Control knob not fully pressed in
2. Control knob not pressed in long enough

3. Equipment shutoff valve not fully open
4. Pilot flame not touching thermocouple,

which allows thermocouple to cool,
causing pilot flame to go out. This prob-
lem could be caused by one or both of
the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot

5. Thermocouple connection loose at con-

trol valve

6. Thermocouple damaged
7. Control valve damaged

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry

3. Tighten nut holding piezo ignitor to base

panel of log set. Nut is located behind
base panel

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace piezo ignitor
7. Replace piezo ignitor

1. Turn on gas supply or open equipment

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is re-
moved

5. Clean ODS/pilot (see Cleaning and

Maintenance, page 15) or replace ODS/
pilot assembly

6. Replace gas control

1. Press in control knob fully
2. After ODS/pilot lights, keep control

knob pressed in 30 seconds

3. Fully open equipment shutoff valve
4. A) Contact local natural gas company

B) Clean ODS/pilot (see Cleaning and
Maintenance, 
page 15) or replace ODS/
pilot assembly

5. Hand tighten until snug, then tighten 1/4

turn more

6. Replace thermocouple
7. Replace control valve

OBSERVED PROBLEM

When ignitor button is pressed, there is no
spark at ODS/pilot

When ignitor button is pressed, there is
spark at ODS/pilot but no ignition

ODS/pilot lights but flame goes out when
control knob is released

Note:

 For additional help, visit DESA

International’s technical service web site
at 

www.desatech.com

.

Note:

 All troubleshooting items are listed in

order of operation.

www.desatech.com

Summary of Contents for Comfort Glow S39NT

Page 1: ...If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adj...

Page 2: ...urn heater off If heated the vapors from these products may create a white pow der residue within burner box or on adjacent walls or furniture 8 This heater needs fresh outside air ven tilation to run...

Page 3: ...UNPACKING 1 Remove top inner pack 2 Tilt carton so that stove is upright 3 Remove protective side packaging 4 Slide stove out of carton 5 Remove protective plastic wrap 6 Remove screen by lifting and...

Page 4: ...eater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the following in structions to insure proper fre...

Page 5: ...rect vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the...

Page 6: ...tilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within...

Page 7: ...reater clearances from floor ceiling and adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must ma...

Page 8: ...r cleaning Install in piping system betweenfuelsupplyandheater Locatesedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from go...

Page 9: ...nnect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 7 2 Press...

Page 10: ...ols required Phillips screwdriver NOTICE Shutoffgasheaterduring the following blower installation 1 Remove 2 screws from rear tabs on top trim Pull trim forward to remove see Figure 11 2 Remove top pa...

Page 11: ...inside control compartment door in front of stove see Figure 16 15 Using two screws provided in blower kit mount blower speed control hous ing to mounting tab in left side of lower control compartment...

Page 12: ...after servicing Wiring Diagram Decal Figure 18 Attaching Wire Harness to ThermostaticSwitchandCoverAssembly Thermostatic Switch Mounted to Cover Wire Harness Lower Hole Figure 19 Assembling Thermosta...

Page 13: ...ighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier th...

Page 14: ...n and burner flame patterns often PILOT FLAME PATTERN Figure 23 shows a correct pilot flame pat tern Figure 24 shows an incorrect pilot flame pattern Note Appearance of pilot assembly may vary by mode...

Page 15: ...cleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or home center may carry compressed air in a can You can...

Page 16: ...ged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set...

Page 17: ...ute 2 Operate burner until air is removed from line Have gas line checked by local natu ral gas company 3 Observe minimum installation clearances see pages 7 through 9 4 Clean burner see Cleaning and...

Page 18: ...ater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Burner flame is excessively large and is very near or to...

Page 19: ...ent Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462...

Page 20: ...20 107434 VENT FREE NATURAL GAS PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S39NT 7 6 9 4 10 3 2 1 14 5 12 11 10 8 13...

Page 21: ...manual KEY PART NO NUMBER DESCRIPTION QTY 1 107433 02 Log Set 1 2 104285 01 ODS Pilot NG 1 3 098249 01 ODS Nut 2 4 107090 01 Burner Outlet Tube 1 5 107089 01 Inlet Tube 1 6 102843 01 Burner Clip 1 7...

Page 22: ...107434 VENT FREE NATURAL GAS PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S39NT 1 10 4 13 3 2 14 7 16 15 11 18 20 5 6 9 8 17 12 23 21 19 19 26 26 22 22 21 25...

Page 23: ...9 107080 01CK Firebox Floor 1 10 107081 01CJ Firebox Top 1 11 107365 01CK Screen Assembly 1 12 101382 01 Valve Bracket 1 13 107092 01 Brass Trim Bottom 1 14 107093 01 Brass Trim Firebox 1 15 105576 0...

Page 24: ...nt part s call DESA International s Parts Department at 1 800 972 7879 for referral information WhencallingDESAInternational haveready model number of your heater the replacement part number ACCESSORI...

Page 25: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Page 26: ...sedbyimproperinstallation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTEN...

Reviews: