background image

15

105616

OWNER’S MANUAL

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information,
column 1.

2.

Make sure manual shutoff valve is
fully open.

3.

Set selector switch in the OFF position.

 WARNING:

• If fireplace has glass doors,

never operate this heater with
glass doors closed. If you oper-
ate heater with doors closed,
heat buildup inside fireplace will
cause glass to burst. Also if
fireplace opening has vents at
the bottom, you must open the
vents before operating heater.

• You must operate this heater

with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.

 WARNING: Burner will come

on automatically within one
minute when the selector switch
is in the ON position after the
pilot is lit.

 CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

O

F

F

PIL

OT

O

N

LO

IH

REMOTE
OFF
ON

Control Knob

Ignitor Button

Selector
Switch in
OFF Position

Flame Adjustment Knob

Figure 26 - Control Knob and Ignitor Button Location

Figure 27 - Pilot

Ignitor
Electrode

Pilot Burner

 WARNING: Make sure the

selector switch is in the OFF po-
sition when you are away from
home for long periods of time.
Heater will come on automati-
cally with selector switch in the
ON position.

4.

Press in and turn control knob clock-
wise 

  to the OFF position.

5.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, column 1. If you don’t
smell gas, go to the next step.

6.

Press in and turn control knob coun-
terclockwise  

  to the PILOT

position. Press in control knob for
five (5) seconds (see Figure 26).

Note:

 You may be running this

heater for the first time after hook-

ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.

7.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
burner. If needed, keep pressing ig-
nitor button until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
 on page 16.

8.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

Note:

 If pilot goes out, repeat steps

4 through 8.

9.

Slightly push in and turn control
knob counterclockwise 

 to the

ON position.

10. Wait one minute and switch selector

switch to the ON position to light
burner.

11. Set flame adjustment knob to any

level between HI and LO.

OPERATING
FIREPLACE

FOR YOUR

SAFETY READ

BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

Summary of Contents for Comfort Glow CGCF26PRA

Page 1: ...s or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Page 2: ...he control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplace is designed to be sm...

Page 3: ...es one hardware packet and one remote con trol packet which includes batteries 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FE...

Page 4: ...ort see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long screws through burner support into the log and tighten Place branches on branch support see Figure 2 6...

Page 5: ...ila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the f...

Page 6: ...nt gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu...

Page 7: ...re 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an a...

Page 8: ...from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is beneficial insta...

Page 9: ...ect blower to electrical source Option one Route blower electrical cord through side or rear access door of fireplace Plug electrical cord into electrical outlet 1 Frame in rough opening Use dimen sio...

Page 10: ...x assembly Blower accessory should be installed if it is being used see Accesso ries page 24 1 Unscrew four brass screws that attach top louver to fireplace Remove louver from fireplace and set aside...

Page 11: ...male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Installsedimenttrapinsupplylineasshown in Figure 17 Locate sediment t...

Page 12: ...o allow accessibility fromthefireplace seeFigure19 The flexible gas supply line con nection to the manual shutoff valve should be accessible Branch Support Screen Screen Shipping Screw Shoulder Screw...

Page 13: ...supply tank to manual shutoff valve see Fig ure 21 Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 4 Correct all leaks at once INSTALLATION Continued CHECKING GAS CON...

Page 14: ...ed in step one see Figure 24 Figure 22 Switch Plate and Wiring Harness Screw Switch Plate Black Wire Red Wire Figure 23 Attaching Battery to Receiver Battery Clip 9 Volt Battery Receiver Terminal Wire...

Page 15: ...light pilot The pilot is attached to the burner If needed keep pressing ig nitor button until pilot lights Note If pilot does not stay lit con tact a qualified service person or gas supplier for repa...

Page 16: ...lector switch in the REMOTE posi tion when the pilot is not lit This will drain the battery IMPORTANT Be sure to press the ON OFF buttons on the hand held remote control unit for up to 3 sec onds to...

Page 17: ...Troubleshooting pages 19 through 21 Pilot Burner Thermocouple INSPECTING BURNERS CLEANING AND MAINTENANCE WARNING Turn off fireplace and let cool before cleaning CAUTION You must keep control areas bu...

Page 18: ...r fireplace the replacement part number SPECIFICATIONS Btu Variable 15 000 26 000 Type Gas Propane LP Only Ignition Piezo Manifold Pressure 8 W C Inlet Gas Pressure in of water Maximum 14 Minimum 11 D...

Page 19: ...ect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace...

Page 20: ...ion and Venti lation requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas com...

Page 21: ...burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common with...

Page 22: ...ANE COMPACT FIREPLACE ILLUSTRATED PARTS BREAKDOWN CGCF26PRA 11 11 29 30 38 38 7 35 26 36 10 40 40 7 24 1 2 8 15 6 21 31 32 13 18 22 5 27 20 19 16 28 1 28 2 23 39 25 33 34 19 14 14 1 37 18 12 4 4 39 9...

Page 23: ...l Base 1 16 102649 02CJ Branch Support 1 17 097159 04 Piezo 1 18 099387 13 Pilot Tube 1 19 098271 07 Ignitor Cable 1 20 098251 03 Injector 1 21 098250 01 Injector Holder 1 22 098249 01 Nut M5 6 23 103...

Page 24: ...classic lines Available in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly instructions in cluded Three sided brass trim kit included ACCESSORIES Purchase these fi...

Page 25: ...342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bowling Green KY 42103 3413 502 846 1199 1 800 654 8534 Fax 1 800 846 0090...

Page 26: ...defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner...

Reviews: