background image

24

105616

VENT-FREE PROPANE COMPACT FIREPLACE

CORNER MANTEL WITH
BUILT-IN HEARTH BASE
AND TRADITIONAL SQUARE
LEG STYLING

Finished Oak Veneer- GMC43F
Unfinished Oak Veneer - GMC44U
Finished Walnut Hardwood
Veneer - GMC38F
Unfinished Hardwood Veneer -
GMC39U

For use with fireplace. A hardwood mantel
and hearth base offers compact styling and
completes the fireplace look. Available in a
stained or an unfinished (ready to stain or
paint) Oak Veneer over hardwood. Com-
plete assembly instructions included. Three-
sided brass trim kit included.

CABINET MANTEL WITH
BUILT-IN HEARTH BASE

Unfinished Hardwood Veneer-
GMC16U
Walnut Finished Hardwood
Veneer- GMC15F
Medium Stained Oak Veneer-
GMC17F

For use with fireplace. A hardwood mantel
and hearth base offers compact styling and
completes the fireplace look. Available in a
walnut stain, medium oak stain, or an unfin-
ished hardwood, ready to stain or paint.
Complete assembly instructions included.
Three-sided brass trim kit included.

CORNER MANTEL WITH
BUILT-IN HEARTH BASE

Unfinished Hardwood Veneer-
GMC20U
Finished Hardwood Veneer-
GMC19F

For use with fireplace. Space-saving mantel
and hearth base corner design features clean,
classic lines. Available in a walnut finish or
an unfinished hardwood, ready to stain or
paint. Complete assembly instructions in-
cluded. Three-sided brass trim kit included.

ACCESSORIES

Purchase these fireplace accessories from
your local dealer or Parts Central (see page
27). If they cannot supply these accessories
call DESA International’s Sales Depart-
ment at 1-800-458-2472 for referral infor-
mation. You can also write to the address
listed on the back page of this manual.

MANUAL SHUTOFF VALVE -
GA5010

Manual shutoff valve with 1/8" NPT tap.

THERMOSTATICALLY
CONTROLLED BLOWER KIT -
GA3450T

Provides better heat distribution. Blower
turns off and on automatically, as needed.
Complete installation and operating instruc-
tions included.

BRASS TRIM KIT - GA6095

Optional four-sided brass trim kit for built-
in installations. Provides a finished appear-
ance covering rough edges of wall opening.

RECEIVER AND HAND-HELD
THERMOSTAT REMOTE
CONTROL KIT -
CGHRCT SERIES

For all models. Allows the gas log heater to
be operated in a manually or thermostati-
cally controlled mode. You can turn the gas
log heater on and off without ever leaving
the comfort of your easy chair.

RECEIVER AND HAND-HELD
REMOTE CONTROL KIT -
CGHRC SERIES

For all models. Allows the gas log heater to
be turned on and off by using a hand-held
remote control.

AU

TO

MAN

OFF

ST

ATUS

ON

LO

HI

TEMP

Summary of Contents for Comfort Glow CGCF26PRA

Page 1: ...s or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Page 2: ...he control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplace is designed to be sm...

Page 3: ...es one hardware packet and one remote con trol packet which includes batteries 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FE...

Page 4: ...ort see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long screws through burner support into the log and tighten Place branches on branch support see Figure 2 6...

Page 5: ...ila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the f...

Page 6: ...nt gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu...

Page 7: ...re 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an a...

Page 8: ...from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is beneficial insta...

Page 9: ...ect blower to electrical source Option one Route blower electrical cord through side or rear access door of fireplace Plug electrical cord into electrical outlet 1 Frame in rough opening Use dimen sio...

Page 10: ...x assembly Blower accessory should be installed if it is being used see Accesso ries page 24 1 Unscrew four brass screws that attach top louver to fireplace Remove louver from fireplace and set aside...

Page 11: ...male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Installsedimenttrapinsupplylineasshown in Figure 17 Locate sediment t...

Page 12: ...o allow accessibility fromthefireplace seeFigure19 The flexible gas supply line con nection to the manual shutoff valve should be accessible Branch Support Screen Screen Shipping Screw Shoulder Screw...

Page 13: ...supply tank to manual shutoff valve see Fig ure 21 Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 4 Correct all leaks at once INSTALLATION Continued CHECKING GAS CON...

Page 14: ...ed in step one see Figure 24 Figure 22 Switch Plate and Wiring Harness Screw Switch Plate Black Wire Red Wire Figure 23 Attaching Battery to Receiver Battery Clip 9 Volt Battery Receiver Terminal Wire...

Page 15: ...light pilot The pilot is attached to the burner If needed keep pressing ig nitor button until pilot lights Note If pilot does not stay lit con tact a qualified service person or gas supplier for repa...

Page 16: ...lector switch in the REMOTE posi tion when the pilot is not lit This will drain the battery IMPORTANT Be sure to press the ON OFF buttons on the hand held remote control unit for up to 3 sec onds to...

Page 17: ...Troubleshooting pages 19 through 21 Pilot Burner Thermocouple INSPECTING BURNERS CLEANING AND MAINTENANCE WARNING Turn off fireplace and let cool before cleaning CAUTION You must keep control areas bu...

Page 18: ...r fireplace the replacement part number SPECIFICATIONS Btu Variable 15 000 26 000 Type Gas Propane LP Only Ignition Piezo Manifold Pressure 8 W C Inlet Gas Pressure in of water Maximum 14 Minimum 11 D...

Page 19: ...ect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace...

Page 20: ...ion and Venti lation requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas com...

Page 21: ...burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common with...

Page 22: ...ANE COMPACT FIREPLACE ILLUSTRATED PARTS BREAKDOWN CGCF26PRA 11 11 29 30 38 38 7 35 26 36 10 40 40 7 24 1 2 8 15 6 21 31 32 13 18 22 5 27 20 19 16 28 1 28 2 23 39 25 33 34 19 14 14 1 37 18 12 4 4 39 9...

Page 23: ...l Base 1 16 102649 02CJ Branch Support 1 17 097159 04 Piezo 1 18 099387 13 Pilot Tube 1 19 098271 07 Ignitor Cable 1 20 098251 03 Injector 1 21 098250 01 Injector Holder 1 22 098249 01 Nut M5 6 23 103...

Page 24: ...classic lines Available in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly instructions in cluded Three sided brass trim kit included ACCESSORIES Purchase these fi...

Page 25: ...342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bowling Green KY 42103 3413 502 846 1199 1 800 654 8534 Fax 1 800 846 0090...

Page 26: ...defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner...

Reviews: