background image

16

105616

VENT-FREE PROPANE COMPACT FIREPLACE

OPERATING
FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.

Turn control knob clockwise  
to the OFF position.

2a. Set selector switch in the OFF position.

2b.

If Using Optional Hand-Held Re-
mote:

 Set selector switch in the OFF

position to prevent draining battery.

Shutting Off Burner Only (pilot
stays lit)

You may shut off the burner and keep the
pilot lit by doing one of the following:

1.

Turn control knob clockwise  
to the PILOT position.

2.

Use remote control manual OFF button.

3.

Set selector switch in the OFF position.

1.

Follow steps 1 through 6 under Light-
ing Instructions
, page 15.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 11, on page 15.

MANUAL LIGHTING

PROCEDURE

OPTIONAL REMOTE

OPERATION

Note:

 All remote control accessories must

be purchased separately (see Accessories,
page 24). Follow installation instructions
on pages 14 of this manual.

Thermostat Control Operation

(Optional CGHRCT Series Only) The ther-
mostat control setting on the remote con-
trol unit can be set to any comfort level
between HI and LO. The burner will turn
on and off automatically to maintain the
comfort level you select. The ideal comfort
setting will vary by household depending
upon the amount of space to be heated, the
output of the central heating system, etc.

NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See 

Lighting

Instructions on page 15.

1.

After lighting, let pilot flame burn for
about one minute. Turn control knob
to ON position. Adjust flame adjust-
ment knob anywhere between HI
and LO. Slide the selector switch to
the REMOTE position. 

NOTE:

 The

burner may light if hand-held remote
ON button was on when selector
switch was last turned off. You can
now turn the burner on and off with
the hand-held remote control unit.

IMPORTANT:

  Do not leave the se-

lector switch in the REMOTE posi-
tion when the pilot is not lit. This will
drain the battery.

IMPORTANT:

 Be sure to press the

ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.

CGHRC Series Operation:

2a. Press the ON/OFF button to turn the

burner on and off. When turning
burner off, the pilot will remain lit.

CGHRCT Series Operation:

2b. Select the MAN (manual) or AUTO

button on the hand-held remote con-
trol unit (see Figure 29, page 17).
• In manual mode, turn burner on

or off by pressing the ON or OFF
buttons on the hand-held remote
control unit.

Figure 28 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation

O

FF

PIL

O

T

O

N

LO

IH

REMOTE
OFF
ON

Flame
Adjustment
Knob

Control Knob

Selector Switch in Remote
Position (Optional Remote Control)

• In auto mode, the room tempera-

ture is controlled by the thermo-
stat in the hand-held remote con-
trol unit. To increase the room tem-
perature, press the top arrow of the
TEMP button. To lower room the
temperature, press the bottom ar-
row of the TEMP button. At higher
settings the heater will run more.

IMPORTANT:

 This remote control

has been specially engineered to take
an air temperature sample every 5.5
minutes in the AUTO mode. It will not
respond immediately to the tempera-
ture setting being turned up or down.

IMPORTANT:

 The hand-held remote

control unit must be near the heater.
Do not keep the hand-held remote
control unit too close to the heater.
The thermostat on the hand-held re-
mote control unit will heat up too
quickly and turn the heater off.

3.

Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used when the sta-
tus button is pressed (see Figure 29,
page 17).

4.

To turn the burner off when operat-
ing in the manual mode, press the
OFF button. If operating in the auto
mode, press the MAN button, then
press the OFF button. The pilot will
remain lit (see Figure 29, page 17).

IMPORTANT: 

To turn the pilot off,

manually turn the control knob on
the heater to the OFF position.

Summary of Contents for Comfort Glow CGCF26PRA

Page 1: ...s or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Page 2: ...he control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplace is designed to be sm...

Page 3: ...es one hardware packet and one remote con trol packet which includes batteries 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FE...

Page 4: ...ort see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long screws through burner support into the log and tighten Place branches on branch support see Figure 2 6...

Page 5: ...ila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the f...

Page 6: ...nt gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu...

Page 7: ...re 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an a...

Page 8: ...from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is beneficial insta...

Page 9: ...ect blower to electrical source Option one Route blower electrical cord through side or rear access door of fireplace Plug electrical cord into electrical outlet 1 Frame in rough opening Use dimen sio...

Page 10: ...x assembly Blower accessory should be installed if it is being used see Accesso ries page 24 1 Unscrew four brass screws that attach top louver to fireplace Remove louver from fireplace and set aside...

Page 11: ...male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Installsedimenttrapinsupplylineasshown in Figure 17 Locate sediment t...

Page 12: ...o allow accessibility fromthefireplace seeFigure19 The flexible gas supply line con nection to the manual shutoff valve should be accessible Branch Support Screen Screen Shipping Screw Shoulder Screw...

Page 13: ...supply tank to manual shutoff valve see Fig ure 21 Apply mixture of liquid soap and water to gas joints Bubbles form ing show a leak 4 Correct all leaks at once INSTALLATION Continued CHECKING GAS CON...

Page 14: ...ed in step one see Figure 24 Figure 22 Switch Plate and Wiring Harness Screw Switch Plate Black Wire Red Wire Figure 23 Attaching Battery to Receiver Battery Clip 9 Volt Battery Receiver Terminal Wire...

Page 15: ...light pilot The pilot is attached to the burner If needed keep pressing ig nitor button until pilot lights Note If pilot does not stay lit con tact a qualified service person or gas supplier for repa...

Page 16: ...lector switch in the REMOTE posi tion when the pilot is not lit This will drain the battery IMPORTANT Be sure to press the ON OFF buttons on the hand held remote control unit for up to 3 sec onds to...

Page 17: ...Troubleshooting pages 19 through 21 Pilot Burner Thermocouple INSPECTING BURNERS CLEANING AND MAINTENANCE WARNING Turn off fireplace and let cool before cleaning CAUTION You must keep control areas bu...

Page 18: ...r fireplace the replacement part number SPECIFICATIONS Btu Variable 15 000 26 000 Type Gas Propane LP Only Ignition Piezo Manifold Pressure 8 W C Inlet Gas Pressure in of water Maximum 14 Minimum 11 D...

Page 19: ...ect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace...

Page 20: ...ion and Venti lation requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas com...

Page 21: ...burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common with...

Page 22: ...ANE COMPACT FIREPLACE ILLUSTRATED PARTS BREAKDOWN CGCF26PRA 11 11 29 30 38 38 7 35 26 36 10 40 40 7 24 1 2 8 15 6 21 31 32 13 18 22 5 27 20 19 16 28 1 28 2 23 39 25 33 34 19 14 14 1 37 18 12 4 4 39 9...

Page 23: ...l Base 1 16 102649 02CJ Branch Support 1 17 097159 04 Piezo 1 18 099387 13 Pilot Tube 1 19 098271 07 Ignitor Cable 1 20 098251 03 Injector 1 21 098250 01 Injector Holder 1 22 098249 01 Nut M5 6 23 103...

Page 24: ...classic lines Available in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly instructions in cluded Three sided brass trim kit included ACCESSORIES Purchase these fi...

Page 25: ...342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bowling Green KY 42103 3413 502 846 1199 1 800 654 8534 Fax 1 800 846 0090...

Page 26: ...defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner...

Reviews: