background image

6

103427

UNVENTED PROPANE GAS LOG HEATER

NOTICE: Manual control heaters
may be used as a vented product.
If so, you must always run heater
with chimney flue damper open.
If running heater with damper
open, non-combustible material
above fireplace opening is not
needed. Go to 

Installing Damper

Clamp Accessory for Vented
Operation, page 8.

Minimum Non Combustible
Material Clearances

If Not Using Mantel

Note:

 If using a mantel, go to page 7. If not

using a mantel, follow the information on
this page.

You must have non combustible material(s)
above the fireplace opening. Non combus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have non combustible
material behind it. Non combustible mate-
rial must extend at least 8" up (for all mod-
els). If non combustible material is less than
12", you must install the fireplace hood
accessory (24" and 30" models only). See
chart on page 7, column 1 and Figure 5 for
minimum clearances.

IMPORTANT:

 If you cannot meet these

minimum clearances, you must operate
heater with chimney flue damper open. Go
to Installing Damper Clamp Accessory for
Vented Operation,
 page 8.

INSTALLATION AND
CLEARANCES

(Vent-Free Operation Only)

Figure 5 - Minimum Clearance to Wall and
Ceiling

 WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.

LOG SIZING REQUIREMENTS

Log

Minimum Firebox Size

Size

Height

Depth Front Width

18"

17"

14"

20"

24"

17"

14"

26"

30"

17"

14"

32"

MINIMUM FIREPLACE
CLEARANCE TO
COMBUSTIBLE MATERIALS

Log Size

18", 24", 30"

Side Wall

16"

Ceiling

42"

Floor

5"

Carefully follow the instructions below. This
will ensure safe installation into a masonry
or U.L. listed manufactured fireplace.

Minimum Wall and Ceiling
Clearances (see Figure 5)

A. Clearances from the side of the fire-

place opening to any combustible wall
should not be less than 16 inches.

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 42 inches.

42"

16"

INSTALLATION

NOTICE: A qualified service per-
son must install heater. Follow
all local codes.

 WARNING: Before installing

in a solid fuel burning fireplace,
the chimney flue and firebox must
be cleaned of soot, creosote,
ashes and loose paint by a quali-
fied chimney cleaner. Creosote
will ignite if highly heated.  In-
spect chimney flue for damage. If
damaged, operate heater with flue
damper closed.

 WARNING: Seal any fresh air

vents or ash clean-out doors lo-
cated on floor or wall of fireplace.
If not, drafting may cause pilot
outage or sooting. Use a heat-
resistant sealant. Do not seal
chimney flue damper.

 WARNING: Never install the

heater
• in a bedroom or bathroom un-

less installed as a vented ap-
pliance, see page 8

• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• in high traffic areas
• in windy or drafty areas

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities in the air (such
as tobacco smoke) exist, may
discolor walls.

IMPORTANT: 

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation
, pages 4 and 5.

CHECK GAS TYPE

Use only propane gas. If your gas supply is
not propane, do not install heater. Call
dealer where you bought heater for proper
type heater.

NOTICE: State or local codes may
only allow operation of this appli-
ance in a vented configuration.
Check your state or local codes.

Continued

Summary of Contents for American Oak Design Unvented Propane Gas Log Heater Model Split Oak and American Oak Design

Page 1: ...sup plier call the fire department Installation and service must be performed by a qualified installer ser vice agency or the gas supplier WARNING Improper installation adjust ment alteration service...

Page 2: ...spect chimney flue for damage If damaged operate heater with flue damper closed 7 If fireplace has glass doors never op erate this heater with glass doors closed If you operate heater with doors close...

Page 3: ...n is not permitted 1 Remove logs and heater base assem bly from carton Note Do not pick up heater base assembly by burners This could damage heater Always handle base assembly by grate 2 Remove all pr...

Page 4: ...3 per kw of the aggregate inputratingofallappliancesinstalledinthat space Rooms communicating directly with the space in which the appliances are in stalled through openings not furnished with doors a...

Page 5: ...e ANSI Z223 1 1992 Section 5 3 VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you m...

Page 6: ...learances see Figure 5 A Clearances from the side of the fire place opening to any combustible wall should not be less than 16 inches B Clearances from the top of the fireplace opening to the ceiling...

Page 7: ...antel shelf See chart below and Figures 7 and 8 page 8 for minimum clearances IMPORTANT Ifyoucannotmeettheseminimumclearances youmustoperateheaterwith chimney flue damper open Go to Installing Damper...

Page 8: ...050 GA6052 Top of Fireplace Opening Underside of Mantel Shelf Floor Clearances A If installing appliance on the floor level you must maintain the minimum dis tance of 14 to combustibles see Fig ure 9...

Page 9: ...xible gas hose and fittings not provided if allowed by local codes sealant resistant to LP gas not provided electric drill with 3 16 masonry drill bit 1 Apply pipe joint sealant lightly to male thread...

Page 10: ...excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain...

Page 11: ...on necting to Gas Supply page 10 CHECKING GAS CONNECTIONS ON POSITION OFF POSITION Figure 16 Manual Shutoff Valve Open Closed Manual Shutoff Valve Figure 17 Checking Gas Joints Thermostat Gas Valve or...

Page 12: ...Slide rear log 1 into place behind rear burner see Figure 18 2 Slide front log 2 into place behind front burner Make sure tabs at bottom of log are behind front burner see Fig ure 19 3 Place crossover...

Page 13: ...behind metal posts on front burner Make sure the grooves in the bottom of the log fit over the grate Bring the log forward next to the metal posts The pegs on the log must be on top see Figure 23 3 S...

Page 14: ...lace will cause glass to burst Also if fireplace opening has vents at the bottom you must open the vents before operating heater You must operate this heater withafireplacescreeninplace Make sure fire...

Page 15: ...mostat Controlled Models Only Thethermostatcontrolknobcanbesetto anycomfortlevelbetweenHiandLo The thermostat will gradually modulate the heatoutputandflameheightfromhigher to lower settings or pilot...

Page 16: ...tting Off Burners Only pilot stays lit 1 Turn the control knob clockwise Clockwise to the HIGH position 2 Press in and turn control knob clock wise Clockwise to the pilot position Thermocouple Ignitor...

Page 17: ...lames with yellow tipping Dirt or other fine particles are burned by heater causing brief patches of orange flame CORRECT FLAME PATTERN AT HIGH POSITION INCORRECT FLAME PATTERN AT HIGH POSITION Figure...

Page 18: ...ODS pilot 6 Thermocouple connection loose at con trol valve 7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep...

Page 19: ...debris If found clean burner s see Cleaning and Maintenance page 17 2 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a...

Page 20: ...ntrol valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Thermostat sensing bulb needs to be repositioned REMEDY 1 This is common with...

Page 21: ...thermostat sensing bulb IMPORTANT Do not force or bend the thermostat sensing bulb or capillary 4 The thermostat sensing bulb may be located to the lower right front side of fireplace Determine locat...

Page 22: ...ropane Only Propane Only Propane Only Ignition Piezo Piezo Piezo Manifold Pressure 7 9 W C 7 9 W C 7 9 W C Inlet Gas Pressure in of water Maximum 14 14 14 Minimum 11 11 11 For purpose of input adjustm...

Page 23: ...CS30NV A B CS30PV A B VENT FREE LOGMATE FIRE BOXES Available in 32 36 and 42 models May be paired with the logs listed below Circulating fireboxes feature louvers and anoptionalblower Non circulating...

Page 24: ...G HEATER ILLUSTRATED PARTS BREAKDOWN Variable Manually Controlled Models 18 20 19 26 25 21 21 27 28 6 7 8 29 29 25 10 9 11 12 13 15 22 23 27 1 27 2 24 7 1 7 2 14 16 17 4 5 3 2 1L 1R VS18PVB CFS18PVB V...

Page 25: ...ezoIgnitor 1 12 098867 10 098867 10 098867 10 Gas Regulator 1 13 M11084 38 M11084 38 M11084 38 Screw 2 14 101011 01 101011 02 101011 03 Inlet Tube 1 15 098354 01 098354 01 098354 01 Control Knob 1 16...

Page 26: ...ROPANE GAS LOG HEATER 31 6 25 6 7 8 9 10 11 8 8 29 13 12 13 14 15 16 18 17 19 24 26 27 7 1 7 2 29 22 23 21 28 20 30 10 1 10 2 4 5 3 2 1R 1L ILLUSTRATED PARTS BREAKDOWN Thermostat Controlled Models VS1...

Page 27: ...01331 06 101331 07 Base Assembly with decals 1 13 098271 07 098271 06 098271 06 Ignitor Cable 1 14 102445 01 102445 01 102445 01 Piezo Ignitor 1 15 098867 10 098867 10 098867 10 Gas Regulator 1 16 M11...

Page 28: ...ED PROPANE GAS LOG HEATER ILLUSTRATED PARTS BREAKDOWN Variable Manually Controlled Models VL18PV VL24PV VL30PV 18 20 19 26 25 21 21 27 28 6 7 8 29 29 25 10 9 11 12 13 15 22 23 27 1 27 2 24 7 1 7 2 14...

Page 29: ...98867 10 098867 10 Gas Regulator 1 13 M11084 38 M11084 38 M11084 38 Screw 2 14 101011 01 101011 02 101011 03 Inlet Tube 1 15 098354 01 098354 01 098354 01 Control Knob 1 16 098462 03 098462 03 098462...

Page 30: ...___________________________ _______________________________________________________________________________________________ ____________________________________________________________________________...

Page 31: ...______________________________________ _______________________________________________________________________________________________ _________________________________________________________________...

Page 32: ...ns furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents...

Reviews: