14
A q u a - B o x O w n e r ’ s M a n u a l
www.deroyal.com
800.251.9864
ELECTRICAL CONNECTIONS: RINSING UNITS
For Model 1300-R only, the following steps provide the instructions for the electrical connections. The 1300-R ships completely
pre-wired. Other than plugging the unit into a standard 110/120 AC Volt outlet, no electrical connections are required for
installation. The following instructions are provided should the controller box need to be disconnected for some reason (i.e.,
replacement).
1. Remove the cover from the control box
by unscrewing the four plastic cover screws.
2. Feed the wiring harness into the
connection on the large box. Tighten fitting
and attach the marked wires to the terminal
strip marked the same.
3. Connect the three wires marked Q1,
Q2, and Q3 to the terminal. Connect the
white common and the green ground to the
strip marked the same.
4. Plug the control box into a standard
110/120 Volt electrical outlet. The electrical
connection may be hard wired if preferred.
The program will start and the time needs
to be set. Press ESC, scroll down to the
clock, press OK and adjust the clock with
the arrow buttons Press OK again when the
time is set, close the program out and go to
start. Your clock should now be set.
5. The control box cover should be replaced
by screwing clockwise the four plastic cover
screws.
GROUND
COMM
Q3
Q2
Q1