7.6. Pressure test function
NOTE
In normal operation the screwdriver starts once the turn-on threshold has
been exceeded and stops once it has dropped below the turn-off threshold.
Test the function of the push-to-start as follows:
1. start
test
function
via menu function F11.
2.
hold the screwdriver vertically.
3.
in the lower segment of the display a line appears (
|
| |
).
4.
push down on the screwdriver.
5.
when the turn-off threshold has been exceeded a second line appears (
| |
|
).
6.
when the turn-off threshold has been exceeded a third line appears (
| |
|
).
7.7. Display test
If you want to test whether all segments and buttons are correctly functioning on the
screwdriver display then you can switch the display test on either by clicking on “Activate”
in the ComCenter ED menu System
Maintenance or when using a screwdriver without
ComCenter ED by clicking on the menu F10 on the screwdriver and setting the value at 2
(switch on display test).
The test can be switched off by clicking on “Deactivate” in the ComCenter ED menu Sys-
tem
Maintenance or when using the screwdriver without ComCenter ED by clicking the
button on the screwdriver and setting the value at 1 (switch off display test) in the menu
F10.
If you switch on the screwdriver and on the display there are three horizontal lines shown
at the top, middle and bottom
(
≡≡≡
)
then the screwdriver is in display test mode.
You can bypass the test by clicking the button
and the test will begin instead the next
time the tool is started.
Once the test has been started, it must be completed through to the end.
Carry out a display test as follows:
1. Press the button
to start the test, a line in the middle of the display (
– – –
) shows
the start of the test.
2. Press the button
five times
3. S1 is displayed each time as confirmation
4. Press the button
five times
5. S2 is displayed each time as confirmation
6. Press the button
five times
7. S3 is displayed each time as confirmation
8. A line appears in the middle of the display (
– – –
) to signal the end of the key test
9. The green and red LEDs are switched on
10. Press any key on the screwdriver in order to start the segment test
11. The LEDs switch off again