Notice SecurAccess PMR
42
Proceed as shown below :
Setting to modify
Code
Setting choice
Factory settings are shown in grey
Conf.
Talk time duration
0 7
Enter the number of minutes of talk time (from 0 up to 9).
Note : 0 = no limit (factory setting)
*9
3.14. Call barring
Call barring parameters allow limiting the keypad dialing
Setting to modify
Code
Setting choice
Factory settings are shown in grey
Conf.
Call barring activation
8 0
0 : Deactivated (no limit)
1 : Activated
(factory setting)
*9
1
er
not allowed first digit
8 1
Digit not allowed.
# if no digit (factory setting)
*9
2
nd
not allowed first digit
8 2
Digit not allowed.
# if no digit (factory setting)
*9
1
er
not allowed first two digits
8 3
The two digits not allowed.
## if no digit (factory setting)
*9
2
nd
not allowed first two digits
8 4
The two digits not allowed.
## if no digit (factory setting)
*9
3
rd
not allowed first two digits
8 5
The two digits not allowed.
## if no digit (factory setting)
*9
4
th
not allowed first two digits
8 6
The two digits not allowed.
## if no digit (factory setting)
*9
Limitation of digits
8 7
Maximum digits allowed from 01 to 29
« ## » no limitation (factory setting)
« 00 » keypad dialing not allowed
*9
3.15. Changing the programming access code
Programming access code setting coming out from factory is : 0000
This code can be modified as indicated below:
Setting to modify
Code
Setting choice
Factory settings are shown in grey
Conf.
Changing the setting code
9 0
Enter the new 4 digits access code twice
note : 0000 = factory setting
*9
Your new access code :
3.16. Reset
Caution: this operation switches back the unit to all factory settings; it also erases all numbers stored
in memories. This operation can be done locally or remotely.
Local reset:
1. Open the unit and access to the PCB
2. Connect the unit to a powered telephone line.
3. Depress the RAZ button located on the PCB for at least 4 seconds (see page 5)
4.
The unit starts emitting several “beep” tones during the reset